• 제목/요약/키워드: shaking test

검색결과 536건 처리시간 0.031초

실내 진동대 실험을 통한 하구둑 구조물의 내진 안정성에 관한 연구 (A Study on Stability of Earthquake in Estuary Barrage through Shaking Table Test)

  • 신은철;강현회;류병현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.38-44
    • /
    • 2010
  • Shaking table tests were performed to reproduce the dynamic behavior of estuary barrage and its subbase soil which can be potentially damaged during earthquake loading. For understanding the vibration effect to the ground during earthquake, the model was formulated with 1/300 scale of prototype estuary barrage and subbase soil. Scott and Iai(1989) proposed the law of the similarity for similar experimental conditions. The laboratory model shaking table test was conducted under the vibration condition of simulated earthquake of 0.154g. The horizontal displacement on the structure was measured during the shaking table test. The pore water pressure was also monitored for the underground layers of soil. The field horizontal displacement and the pore water pressure can be predicted by using the results of the laboratory shaking table test.

  • PDF

Prediction of dynamic behavior of full-scale slope based on the reduced scale 1 g shaking table test

  • Jin, Yong;Kim, Daehyeon;Jeong, Sugeun;Park, Kyungho
    • Geomechanics and Engineering
    • /
    • 제31권4호
    • /
    • pp.423-437
    • /
    • 2022
  • The objective of the study is to evaluate the feasibility of the dynamic behavior of slope through both 1 g shaking table test and numerical analysis. Accelerometers were installed in the slope model with different types of seismic waves. The numerical analysis (ABAQUS and DEEPSOIL) was used to simulate 1 g shaking table test at infinite boundary. Similar Acceleration-time history, Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) were obtained, which verified the feasibility of modeling using ABAQUS and DEEPSOIL under the same size. The influence of the size (1, 2, 5, 10 and 20 times larger than that used in the 1 g shaking table test) of the model used in the numerical analysis were extensively investigated. According to the similitude law, ABAQUS was used to analyze the dynamic behavior of large-scale slope model. The 5% Damping Spectral acceleration (SA) and Spectral acceleration amplification factor (Fa) at the same proportional positions were compared. Based on the comparison of numerical analyses and 1 g shaking table tests, it was found that the 1 g shaking table test result can be utilized to predict the dynamic behavior of the real scale slope through numerical analysis.

Effects of excess pore pressure dissipation on liquefaction-induced ground deformation in 1-g shaking table test

  • Wang, B.;Zen, K.;Chen, G.Q.;Kasama, K.
    • Geomechanics and Engineering
    • /
    • 제4권2호
    • /
    • pp.91-103
    • /
    • 2012
  • Focusing on the effect of excess pore pressure dissipation on liquefaction-induced ground deformation, a series of 1-g shaking table tests were conducted in a rigid soil container by use of saturated Toyoura sand, the relative density of which was 20-60%. These tests were subjected to the sinusoidal base shaking with step increased accelerations: 100, 200, 300 and 400 Gals for 2-4 seconds. Shaking table tests were done using either water or polymer fluid with more viscous than water, thus varying the sand permeability of model tests. Excess pore pressures, accelerations, settlements and lateral deformations were measured in each test. Test results are presented in this paper and the effect of sand permeability on liquefaction and liquefaction-induced ground deformation was discussed in detail.

기와집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.362-367
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with tiled roof was performed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

기와집 실물크기 모델의 지진 실험 (Seismic Test of a Full Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

초가집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof)

  • 류혁;김재관;허영철;전봉희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

소형선형 평면뼈대모형의 진동대실험을 통한 하이브리드실험 기법의 검증 (Verification of Hybrid Structural Test Technique by Shaking Table Test of a Linear 2-Dimensional Frame Model)

  • 조성민;최인규;정대성;김철영
    • 한국지진공학회논문집
    • /
    • 제14권6호
    • /
    • pp.33-43
    • /
    • 2010
  • 본 논문은 지진에 의한 구조물의 거동을 평가하기 위한 실험방법 중 최근 국내에 도입되어 연구되고 있는 하이브리드실험에 대한 시스템을 구축하고, 그에 따른 모델개발과 하이브리드실험을 실시하여 하이브리드실험기법의 타당성과 정확도를 평가하기 위함이다. 이를 위해 NEESgrid의 미니모스트 시스템을 벤치마킹하여 여건에 맞게 수정, 보완하였으며 2차원 평면뼈대모형을 개발하여 실험에 적용하였다. 그리고 하이브리드실험 결과의 평가를 위해 국내에서는 거의 시도되지 않았던 진동대실험과 비교를 함으로써 결과의 신뢰도를 높였다. 진동대실험에는 하이브리드실험과 동일한 크기의 실물모형을 제작, 실험하여 크기효과의 영향을 최소화하였다. 두 실험의 결과는 거의 비슷한 것으로 나타나 하이브리드실험이 진동대실험을 대체할 수 있을 것으로 판단된다.

직사각형 액체저장탱크의 동적 응답특성에 관한 진동대 실험 (Shaking Table Test of a Rectangular Liquid Storage Tank)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.209-214
    • /
    • 2000
  • Shaking table tests were performed to investigate dynamic behavior of a three dimensional flexible rectangular liquid storage tank. Response characteristics to the three components of translational motion and three component of rotational motion were studied. The aluminium tank was exposed to the shaking high enough to make it behave in nonlinear range. Only very limited amount of the data have been processed yet. Very interesting phenomena on the effects of non-symmetry have been observed and presented. Test results that show nonlinear behavior under the high intensity shaking are reported.

  • PDF

진동대 실험을 통한 시간영역에 기반한 시스템 식별 (Time Domain based Structural System Identification using Shaking Table Test)

  • 이상현;민경원;강경수;이명규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.331-338
    • /
    • 2004
  • In this paper, stiffness and damping matrices are experimentally constructed using structural modal information on frequencies, damping ratios and modal vectors, which are obtained by shaking table tests. The acceleration of the shaking table is used as the input signal, and the resulting acceleration of each floor is measured as output signal. The characteristic and limitation of modal information from shaking table test are obtained by Common Based-normalized System Identification(CBSI) technique which is based on time domain information.

  • PDF

비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가 (Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test)

  • 이재섭;인성우;정담이;이두용;이상현;조봉호
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.