• 제목/요약/키워드: shaking method

검색결과 391건 처리시간 0.027초

Seismic damage detection of a reinforced concrete structure by finite element model updating

  • Yu, Eunjong;Chung, Lan
    • Smart Structures and Systems
    • /
    • 제9권3호
    • /
    • pp.253-271
    • /
    • 2012
  • Finite element (FE) model updating is a useful tool for global damage detection technique, which identifies the damage of the structure using measured vibration data. This paper presents the application of a finite element model updating method to detect the damage of a small-scale reinforced concrete building structure using measured acceleration data from shaking table tests. An iterative FE model updating strategy using the least-squares solution based on sensitivity of frequency response functions and natural frequencies was provided. In addition, a side constraint to mitigate numerical difficulties associated with ill-conditioning was described. The test structure was subjected to six El Centro 1942 ground motion histories with different Peak Ground Accelerations (PGA) ranging from 0.06 g to 0.5 g, and analytical models corresponding to each stage of the shaking were obtained using the model updating method. Flexural stiffness values of the structural members were chosen as the updating parameters. In model updating at each stage of shaking, the initial values of the parameter were set to those obtained from the previous stage. Severity of damage at each stage of shaking was determined from the change of the updated stiffness values. Results indicated that larger reductions in stiffness values occurred at the slab members than at the wall members, and this was consistent with the observed damage pattern of the test structure.

Shaking Table Model Test of Shanghai Tower

  • Lu, Xilin;Mao, Yuanjun;Lu, Wensheng;Kang, Liping
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.79-83
    • /
    • 2013
  • Shaking table test is an important and useful method to help structural engineers get better knowledge about the seismic performance of the buildings with complex structure, just like Shanghai tower. According to Chinese seismic design guidelines, buildings with a very complex and special structural system, or whose height is far beyond the limitation of interrelated codes, should be firstly studied through the experiment on seismic behavior. To investigate the structural response, the weak storey and crack pattern under earthquakes of different levels, and to help the designers improve the design scheme, the shaking table model tests of a scaled model of Shanghai tower were carried out at the State Key Laboratory of Disaster Reduction in Civil Engineering, Tongji University, Shanghai, China. This paper describes briefly the structural system, the design method and manufacture process of the scaled model, and the test results as well.

소아의 범발성 복막염을 동반한 천공성 충수염에서 복강경하 충수절제술 후 대량 흔들기 세척법 및 배액술의 역할 (The Role of Massive Shaking Irrigation and Abdominal Drainage After Laparoscopic Appendectomy for Panperitonitis Secondary to Perforated Appendicitis in Children)

  • 김우연;정재희
    • Advances in pediatric surgery
    • /
    • 제17권1호
    • /
    • pp.51-57
    • /
    • 2011
  • Use of laparoscopic appendectomy (LA) for perforated appendicitis (PA) in children remains controversial because of the development of postoperative intra-abdominal abscess formation. We developed the irrigation method for the prevention of abscess formation after LA performed for PA in children with severe panperitonitis. We called it 'the shaking irrigation'. The object of this study was to analyze the efficacy of this irrigation method. All cases of PA with severe panperitonitis in children that underwent LA with massive shaking irrigation and drainage between June 2003 and December 2007 were studied retrospectively. We included only PA with panperitonitis and large amounts of purulent ascites throughout the abdomen as well as an inflamed small bowel with ileus. Thirty-four children were involved in this study. The mean patient age was eight years. The mean amount of irrigation fluid was 8.2 L (range: 4-15 L), The mean operative time was 89.5 min. The mean length of the hospital stay was 5.1 days. There were no postoperative intra-abdominal abscesses. There was no conversion to open surgery. In conclusion, Use of LA in PA with severe panperitonitis in children is safe and effective. Massive shaking irrigation and abdominal drainage appears to prevent intra-abdominal abscesses after LA for PA with panperitonitis.

  • PDF

국제표준(안) 개선을 위한 토양 중 화약물질 추출 효율성 평가 (Assessment on the Extraction Efficiency of Explosive Compounds in Soil for Improving the Working Draft of International Standard)

  • 이군택;정인호;김보현;김동욱
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권1호
    • /
    • pp.42-46
    • /
    • 2012
  • The ISO document of ISO/TC/190/SC3/WG11/N11 is a working draft of international standard (WD) dealing with analytical method for the determination of explosives and related compounds using high performance liquid chromatography. The scope of this WD covers the storage of samples, preparing test portion, extraction and instrumentation. The main purpose of this study was to improve the extraction conditions which were already adopted in the WD. For this purpose, mechanical shaking method could be corresponded up to 18 hours of ultrasonic bath extraction in the WD was tested. Methanol was also tested with the intention of being added as an extracting solvent other than acetonitrile in the WD. According to the results, 16 hours of mechanical shaking method showed statistically the same effectiveness as that of 18 hours of ultrasonic bath extraction. In case of extracting solvent, methanol also showed statistically the same extraction capability as acetonitrile for DNB, TNT, 2-A-DNT and 2,4-DNT. However, the recovery rate of TNB with methanol extraction was 40% higher than that of acetonitrile extraction. Through adding mechanical shaking method into committee draft (cf. the next stage draft of the WD during the process for making international standard), ISO standard of analyzing explosives and related compounds in soil would become more useful in dealing with huge number of field samples in the laboratory. In other aspect, adopting methanol as an alternative extracting solvent would be very effective in the terms of exchangeability with GC-ECD/MS method which is being developed by German experts.

추출조건 및 방법에 따른 인삼내의 panaxydol과 panaxynol의 추출율 비교

  • 박찬엘;윤지용;박창호
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 춘계학술발표대회
    • /
    • pp.493-496
    • /
    • 2000
  • The extraction efficiencies of panaxynol and panaxydol according to extraction temperature were the highest at $80^{cdot}C$ among 65, 80, $95^{cdot}C$ with soxhlet and increased with shaking method when temperature increased from $25^{cdot}C$ to $45^{cdot}C$. The amounts of panaxynol and panaxydol were determined by gas chromatography. In time dependence of extracted amounts of panaxynol and panaxydol using shaking method, the efficiencies of panaxynol and panaxydol were increased during 12 hour. The effect of water swelling on panaxynol and panaxydol extraction efficiency using soxhlet and shaking methods, the efficiencies of panaxynol and panaxydol were decreased as swelling time was increased.

  • PDF

업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교 (Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results)

  • 선휘창;홍상현;노화성
    • 한국지진공학회논문집
    • /
    • 제23권4호
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.

Identification of user's Motion Patterns using Motion Capture System

  • Jung, Kwang Tae;Lee, Jaein
    • 대한인간공학회지
    • /
    • 제33권6호
    • /
    • pp.453-463
    • /
    • 2014
  • Objective:The purpose of this study is to identify motion patterns for cellular phone and propose a method to identify motion patterns using a motion capture system. Background: In a smart device, the introduction of tangible interaction that can provide new experience to user plays an important role for improving user's emotional satisfaction. Firstly, user's motion patterns have to be identified to provide an interaction type using user's gesture or motion. Method: In this study, a method to identify motion patterns using a motion capture system and user's motion patterns for using cellular phone was studied. Twenty-two subjects participated in this study. User's motion patterns were identified through motion analysis. Results: Typical motion patterns for shaking, shaking left and right, shaking up and down, and turning for using cellular phone were identified. Velocity and acceleration for each typical motion pattern were identified, too. Conclusion: A motion capture system could be effectively used to identify user's motion patterns for using cellular phone. Application: Typical motion patterns can be used to develop a tangible user interface for handheld device such as smart phone and a method to identify motion patterns using motion analysis can be applied in motion patterns identification of smart device.

진동대시험을 이용한 DCM공법에 따른 방파제의 동적거동 분석 (Analysis on the Dynamic Behavior of Breakwater with the DCM Method Using the Shaking Table Test)

  • 김영준;박인준
    • 한국지반환경공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.25-32
    • /
    • 2022
  • 최근 우리나라에 리히터 규모 5.0 이상의 지진발생 2건과 규모가 낮은 지진발생이 많아짐에 따라 지진피해가 늘어나면서 내진설계에 대한 많은 연구와 관심이 높아지고 있으며, 그 중 최근 발생한 포항지진으로 인해 항만시설물에 대한 내진설계에도 관심이 높아졌다. 본 연구에서는 1g 진동대시험을 통하여 항만구조물 중 직립식, 경사식 방파제에 대한 지진 시 발생하는 동적거동에 대해서 실험 및 분석을 하였다. 이를 위해 사상법칙을 적용한 모델에 장주기(Hachinohe), 단주기(Ofunato), 인공지진파 총 세가지 지진파를 적용하고, 연약지반의 DCM 공법 보강 여부를 고려하여 실험하였다. 진동대시험결과를 기초로 지진 시 DCM 공법 보강 여부에 따라 직립식과 경사식 방파제의 동적거동에 대하여 가속도 및 수평·수직 변위를 분석하였다. 검토 결과 직립식 및 경사식 방파제 동적거동은 DCM 공법 보강을 한 경우에 지지력 및 강성이 높아짐에 따라 가속도의 증폭이 억제되는 경향을 나타내었다.

이동차량 영상 안정화를 위한 효율적인 흔들림 보정 기법 (An Efficient Shaking Correction Techniques for Image Stabilization of Moving Vehicles)

  • 홍성일;인치호
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.155-162
    • /
    • 2014
  • 본 논문에서는 이동차량 양상 안정화를 위한 효율적인 흔들림 보정 기법을 제안한다. 제안된 흔들림 보정 기법은 입력으로 받은 영상 이미지 프레임의 색상 분리를 통한 변환 및 분리정보에 대한 누적 히스토그램을 계산하였고, 흔들리는 차량용 영상 이미지를 보정한 결과에서 색상 정보를 맞추기 위해 히스토그램 매칭을 하였다. 본 논문에서 제안된 흔들림 보정 기법은 기존 차량 영상 안정화 기술과 비교하였을 때, 휘도 및 컬러 레벨의 비교를 통해 노이즈가 가장 적고 영상의 자연스러움이 더 뛰어난 복원 결과를 얻을 수 있었다. 또한, 흔들림 보정 기법은 메모리를 사용하지 않고 실시간으로 처리를 통해 다른 방법과 비교하여 효율성을 입증하였다.