• Title/Summary/Keyword: sewerage maintenance

Search Result 30, Processing Time 0.029 seconds

Effect of infiltration/inflow by rainfall for sewerage facilities in the area with partially separate sewer system (불완전 분류식 하수처리구역의 강우에 의한 하수도시설의 침입수/유입수 영향 분석)

  • Shin, Jungsub;Han, Sangwon;Yook, Junsu;Lee, Chungu;Kang, Seonhong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.177-190
    • /
    • 2019
  • The purpose of this study was to analyze the effects of sewerage facilities through I/I analysis by rainfall by selecting areas where storm overflow diverging chamber is remained due to the non-maintenance drainage equipment when the sewerage system was reconstructed as a separate sewer system. Research has shown that wet weather flow(WWF) increased from 106.2% to 154.8% compared to dry weather flow(DWF) in intercepting sewers, and that the WWF increased from 122.4% to 257.6% in comparison to DWF in storm overflow diverging chamber. As a result, owing to storm overflow diverging chamber of partially separate sewer system with untreated tributary of sewage treatment plant, rainfall-derived infiltration/inflow(RDII) has been analyzed 2.7 times higher than the areas without storm overflow diverging chamber. Meanwhile, infiltration quantity of this study area was relatively higher than that of other study areas. Therefore, it is necessary to reduce infiltration quantity through sewer pipe maintenance nearby river. Drainage equipment maintenance should be performed not to operate storm overflow diverging chamber in order to handle the appropriate sewage treatment plant capacity for rainfall because it is also expected that RDII due to rain will occur after maintenance. In conclusion, it is necessary to recognize aRDII(allowance of rainfall-derived infiltration/inflow) and to be reflected it on sewage treatment plant capacity because aRDII can occur even after maintenance to the complete separate sewer system.

Economies of Scale in the Sewerage Treatment Sectors of Cheonla Province Area (전라남북도 하수처리시설 운영에 대한 규모의 경제성 분석)

  • Kim, Kyunghag;Yoo, Seung-Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2013
  • This Study includes the information of integrated discussion and economies of scale on local governments' sewerage treatment plant through translog function based on the reality reports of sewerage treatment plant operation published by Ministry of Environment and sewerage statistics data from 2005 to 2010. Based on analysis results from the data of 35 local governments in Jeollanamdo and Jeollabukdo, which are selected as pilot project areas of sewerage facility integration by Ministry of Environment and have low percent of sewered population, it shows the existence of economies of scale. The economies of scale on sewerage treatment show the loss of approximately 22,211 thousand ton/day in sewage treatment, it is 1.7 times compared to the average treatment amount of 35 local governments as of 2010. It means the economies of scale can be achieved by lowering operation cost along with large scale integration in installation, operation and maintenance due to the features of sewerage industry as one of network industry.

하수처리에 관한 금후의 방향

  • Il, Bon-Myeong
    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.2
    • /
    • pp.43-44
    • /
    • 1982
  • What I would like to expect about this mater is that Korea would develop unique techniques of the waste water which are most suitable to social and other relevant conditions of that country, not entirely following models of sewerage construction of U.S.A. or European countries or Japan. Some cements will be made in the followings: (1) The investigation for the diffusion of seperated simple public sewerag, not the large scale sewerage treatment plant. (2) The plan for non-mixed treatment of lining waste water and industrial waste water. (3) Suggestion for "a man of ability" at the university education to cultivate a technologist of facilities and the elemental watchman at the sewerage maintenance.

  • PDF

Survey on sewerage operation/management planning for flooding (I) (하수관거시설의 침수대응 운영·관리 실태 연구 (I))

  • Ryu, Jaena;Hwang, Sung-Hwan;Oh, Jeill;Hyun, In Hwan;Kim, Young-Ran;Kim, Chan-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.265-270
    • /
    • 2009
  • A nationwide questionnaire survey was conducted to investigate the actual conditions of local authorities in operating and maintaining sewerage systems especially for urban flooding. The questionnaire includes the incidences of flooding since 1980, the existence of any guidance for preventing flood damage and the design frequency currently used for sewers in each local authority. Among 160 local authorities responded to the survey, 95(59.3%) has experienced flooding more than once since 1980 while only 36(37.9%) of the 95 has prepared operation/maintenance guidelines for flooding. Most of the respondents have applied the 10 year design frequency for sewer design and 57(35.6%) of them agreed to adjust the 10 year design frequency regulation.

The Environmental Impact Assessment for Sustainable Urban Infrastructure Construction - A Case Study on Wastewater Treatment Plant, Sewerage System and Tailrace - (지속가능한 도시기반시설 건설을 위한 잠재적 환경영향 발생 특성 평가 - 하수처리시설, 하수관거, 방수로를 중심으로 -)

  • Park, Kwang-Ho;Kim, Chang-Hee;Hwang, Yong-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.919-926
    • /
    • 2006
  • In this study, environmental impact assessments of wastewater treatment plant (WWTP), sewerage system, and tailrace were performed using LCA methodology. The life cycle stages were divided into 3 categories; construction stage, maintenance stage and demolition & disposal stage. As a tool of impact assessment, Ecoindicator99 containing fate analysis, exposure & effect analysis and damage analysis, was used. As tile results of WWTP LCA, more than 80% of environmental impact was produced from maintenance stage. On the other hand, most of environmental impact was produced from construction stage in the case of tailrace and sewerage system construction.

A study on Determination Method of the Compliance Concentration of Effluent Limitation from Public Sewage Treatment Works in the Jinwee-stream Watershed Sewer System (유역하수도 공공하수처리시설의 방류수 수질 준수농도 설정방안 연구: 진위천 수계를 중심으로)

  • Jeong, Dong-Hwan;Cho, Yangseok;Kim, Youngseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.493-502
    • /
    • 2015
  • In accordance with the Watershed Sewer System Maintenance Plan enforced on February 2, 2013, the different compliance concentration of effluent limit be applied to effluent discharged from public sewage treatment works(PSTWs) in each watershed on the basis of water quality thereof. With the introduction of watershed sewer system, it is necessary to set the compliance concentration of effluent limit for PSTWs situated in the watershed, by region and PSTW size, to achieve water quality criteria for regional watersheds or target water quality under TMDL program. Watershed Environmental Agencies establish the Watershed Sewer System Maintenance Plan and set the compliance concentrations of effluent limit for PSTWs under the plan. The agencies plan to apply tougher effluent BOD concentration limits in Class I to IV areas. Effluent BOD concentration limits will be toughened from 5~10 mg/L to 3 mg/L in class II~III areas, from 10mg/L to 5mg/L in class IV areas. Uniform application of effluent BOD concentration limits to PSTWs in the watershed sewer system need to be complemented considering type of sewage treatment technology employed and watershed characteristics. Therefore, this study presents method to determine the compliance concentration of effluent limit from PSTWs in the watershed.

Development of a System Dynamics Model for the Efficient Operation and Maintenance of Sewerage Systems (하수도 시스템의 효율적인 운영 및 유지관리를 위한 시스템다이내믹스 모형의 개발)

  • Park, Su-Wan;Lee, Tae-Geun;Kim, Bong-Jae;Kim, Tae-Young
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.1
    • /
    • pp.101-111
    • /
    • 2012
  • In this paper, the feedback loop mechanisms among the operational indices and exogenous variables of a sewerage system that are inherent in the operation and maintenance of a sewerage system were identified using the System Dynamics (SD) modeling methodology. The identified feedback loops were used to develop a SD computer simulation model that can be used to predict future operational conditions of a sewerage system and identified the efficient ways of operation. The data of Busan metropolitan city sewerage system was applied to verify the developed SD model and predict future operational conditions of the system. As a result, it was predicted that sewage treatment efficiency, volume of sewage treatment and cost recovery rate will be gradually increased, whereas service rate which was already very close to the target will remain almost the same as the current value. Furthermore, sensitivity analysis concerning some operational indices was performed in order to discover the policy leverage. As a result, it was found that the exogenous variables related to the pipe maintenance had a great effect on facility using rate, volume of sewage treatment as well as sewage treatment efficiency.

Recent(2008-2019) trend and expectations in future of the water reuse capacity based on the statistics of sewerage in Republic of Korea (최근(2008-2019년) 하수도통계 자료 분석 기반 국내 하수재이용량 예측)

  • Ma, Jeong-Hyeok;Jeong, Seongpil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.477-487
    • /
    • 2021
  • Due to the global climate change, Korean peninsula is has been experiencing flooding and drought severely. It is hard difficult to manage water resources sustainably, because due to intensive precipitation in short periods and severe drought has increased in Korea. Reused water from the wastewater treatment plant (WWTP) could be a sustainable and an alternative water source near the urban areas. In order to understand the patterns of water reuse in Korea, annual water reuses data according to the times and regional governments were investigated from 2008 to 2019. The reused water from WWTP in Korea has been mainly used for river maintenance flow and industrial use, while agricultural use of water reuse has decreased with time. Metropolitan cities in Korea such as Seoul, Busan, Daegu, Ulsan, and Incheon have been mainly used reused reusing water for river maintenance flow. Industrial water reuse has been limitedly applied recently for the planned industrial districts in Pohang, Gumi, Paju, and Asan. By using the collected annual water reuse data from the domestic sewerage statistics of sewerage, the optimistic and pessimistic future estimations of for future annual water reuse were suggested from 2020 to 2040 on a five year interval for every five years.

State of Swerage Systems and Prospects in Korea (우리 나라의 하수도현황과 전망)

  • 김갑수
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

A Study on the Allocation of Permissible Water Pollution Load in the Total Water Pollution Load Management Plan (수질오염 총량관리계획과정의 오염부하량 할당에 관한 연구 - 경기도 광주시를 사례로 -)

  • Kim, Sie-Heon;Rim, Jay-Myung
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.337-346
    • /
    • 2005
  • Pollution load allocation can likely be much controversial, which is essential to formulate the total water pollution load management plan. Existing rules(or guidances) in Korea, can provide no specific criteria for load allocation. Therefore, this paper studied(comprehensively) possible standards how or why to choose any particular allocation method, which was applied in the Gwangju City's load allocation for the satisfaction of set water quality goal. This load allocation is basically focused on the load reduction of domestic wastewater rather than industrial wastewater, because the land-use is strictly regulated and larger sources of pollution are few in the Gwangju City. This paper recommends the city to increase the capacity of sewage treatment plants, promote sewerage maintenance, and set higher effluent standards.