• Title/Summary/Keyword: sewage facility

Search Result 152, Processing Time 0.021 seconds

Power density and fouling propensity of pretreatments in SWRO/PRO hybrid system (전처리기술별 전력밀도 및 파울링에 관한 연구)

  • Koo, Jae-Wuk;Nam, Sookhyun;Sim, Jinwoo;Kim, Eunju;Choi, Yongjun;Hwang, Tae-Mun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.755-764
    • /
    • 2016
  • Pressure retarded osmosis (PRO) processes can be implemented on a number of water types, using different technologies and achieving various power outcomes. In this study, Sewage facility effluent was used for feed solution of PRO and synthetic NaCl water for draw solution. This study was conducted to investigate effect of water quality of pretreatment on power density and flux decline in PRO process. The results show that organic and particulate foulants have to be removed for more stable operation. Flourescence technique with EEM enables to investigate the chemical properties of aquatic organic matter by extracting spectral information. Humic/fulvic matters and soluble microbial by-products were analyzed as the most affecting factors on the PRO performance. As a result of analyzing the whole system based on the energy consumption of the unit process, specific energy consumption(SEC) of the applicable technology for PRO pre-treatment should be about $0.2kWh/m^3$ or less.

A Study on the Li5Fe5O8 Species Affecting the Microwave Heating Performance on the Ternary Li-Fe-Zn Material (3원계 금속산화물로 제조한 마이크로웨이브 발열소재상 Li5Fe5O8 종이 발열성능에 미치는 영향 연구)

  • Jang, Young Hee;Lee, Sang Moon;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.703-709
    • /
    • 2018
  • Dielectric heating materials were prepared through the thermal treatment for composites of Li and Zn type precursors that are major materials being responded to microwave under diversified conditions. The prepared heating material samples were analyzed by SEM and it was confirmed that $Li_5Fe_5O_8$ materials being formed on the surface was a major influencing factor for the heating performance. Heating materials improved the moisture removal in a sludge drying facility, for example, the moisture content of 25 v/v% sludge decreased to 15.22 v/v%. Accordingly, heating materials were confirmed to directly affect the performance and efficiency of the microwave drying process.

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

Optimal Operation of Gas Engine for Biogas Plant in Sewage Treatment Plant (하수처리장 바이오가스 플랜트의 가스엔진 최적 운영 방안)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.28 no.2
    • /
    • pp.18-35
    • /
    • 2019
  • The Korea District Heating Corporation operates a gas engine generator with a capacity of $4500m^3 /day$ of biogas generated from the sewage treatment plant of the Nanji Water Recycling Center and 1,500 kW. However, the actual operation experience of the biogas power plant is insufficient, and due to lack of accumulated technology and know-how, frequent breakdown and stoppage of the gas engine causes a lot of economic loss. Therefore, it is necessary to prepare technical fundamental measures for stable operation of the power plant In this study, a series of process problems of the gas engine plant using the biogas generated in the sewage treatment plant of the Nanji Water Recovery Center were identified and the optimization of the actual operation was made by minimizing the problems in each step. In order to purify the gas, which is the main cause of the failure stop, the conditions for establishing the quality standard of the adsorption capacity of the activated carbon were established through the analysis of the components and the adsorption test for the active carbon being used at present. In addition, the system was applied to actual operation by applying standards for replacement cycle of activated carbon to minimize impurities, strengthening measurement period of hydrogen sulfide, localization of activated carbon, and strengthening and improving the operation standards of the plant. As a result, the operating performance of gas engine # 1 was increased by 530% and the operation of the second engine was increased by 250%. In addition, improvement of vent line equipment has reduced work process and increased normal operation time and operation rate. In terms of economic efficiency, it also showed a sales increase of KRW 77,000 / year. By applying the strengthening and improvement measures of operating standards, it is possible to reduce the stoppage of the biogas plant, increase the utilization rate, It is judged to be an operational plan.

Analysis of Satisfaction on Alley Garden's Components through Urban Regeneration - Focused on Bisan 2·3-dong in Daegu Metropolitan City - (도시재생사업에 따른 골목정원 구성요소의 만족도 분석 - 대구광역시 비산 2·3동을 대상으로 -)

  • Jang, Cheol-Kyu;Hwang, Myeong-Lan;Shin, Jae-Yun;Jung, Sung-Gwan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.6
    • /
    • pp.137-148
    • /
    • 2017
  • This study analyzed the opinions of residents for desirable urban regeneration and suggested an improvement plan for alley environments. This study conducted a questionnaire survey of the residents living in Alley Garden of Bisan 2,3-dong, Daegu Metropolitan City. In the analysis of the importance and satisfaction of Alley Garden components, items related to a safe, cleanly environment such as 'Lighting facility installation', 'Sewage and waste disposal' and 'CCTV installation' had a high level of importance. It was also found that items improved by the Residential Environment Improvement Project and Alley Garden such as 'Lighting facility installation', 'Quantity of herbaceous flowers' and 'Kinds of herbaceous flowers' had a high level of satisfaction. The IPA results showed that items such as 'Empty house maintenance', 'Rest facilities such as benches and pergolas', 'Space for resident interaction' and 'Public parking lot' had a high level of importance, but had a low level of satisfaction, which suggests that they should be improved by priority. As a result of factor analysis, Alley Garden components were classified into four factors: 'Safety and cleanliness', 'Greenness', 'Exchange and convenience facility' and 'Aesthetics renewal'. Based on this classification, a regression analysis was conducted regarding the effects of the four factors on overall satisfaction. Results showed that all four factors had a significant influence on the overall satisfaction and that 'Aesthetics renewal' and 'Safety and cleanliness', respectively showing levels of significance at 0.274 and 0.235, were highly influential to overall satisfaction. Therefore, it was concluded that spaces for resident interaction and rest facilities should be preferentially installed to improve the environment of alleys. For the improvement of the overall satisfaction of alley environments, it was also concluded that residents should be encouraged to engage in activities such as sculpture installation and mural drawing, along with the introduction of safety bells and crime prevention environment design and the implementation of alley beautification projects.

Waste Activated Sludge Digestion with Thermophilic Attached Films (친열성(親熱性) 생물막공법(生物膜工法)을 이용(利用)한 폐활성(廢活性) 슬러지의 혐기성(嫌氣性) 소화(消化))

  • Han, Ung Jun;Kabribk, R.M.;Jewell, W.J.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.31-44
    • /
    • 1985
  • The application of anaerobic attached microbial films in the expanded bed process has recently been examined at high temperatures ($55^{\circ}C$) and with particulate matter. Extrapolation of the kinetics suggested that waste activated sludge (WAS) could be efficiently digested at hydraulic retention times as short as six hours in the expanded bed process. This would represent a 99 percent digester reactor volume reduction and would introduce interesting solids management alternatives if such a high rate process were developed. This paper presents a summary of a 1.5 year study of the feasibility of such a process. Three continuously fed $55^{\circ}C$ laboratory reactor systems were used to define the kinetics and the site of reactions-control completely mixed reactors were compared to the expanded beds (AAFEB) with and without a hydrolysis unit preceding the attached film unit. Well defined laboratory-generated WAS was compared to actual WAS from a domestic sewage treatment facility. Sixty percent of the biodegradable organics were converted in an AAFEB at a 15-hour hydraulic retention time without hydrolysis, whereas greater than 95 perccent of the biodegradable organics were stabilized in a two-stage system consisting of a 3-day HRT hydrolysis reactor followed by a 15-hour HRT AAFEB. The limitations of this high rate process and its potential application are discussed.

  • PDF

Lifecycle cost assessment of best management practices for diffuse pollution control in Han River Basin (한강수계 비점오염원 저감시설의 생애주기비용 평가)

  • Lee, Soyoung;Maniquiz-Redillas, Marla C.;Lee, Jeong Yong;Mun, Hyunsaing;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.448-455
    • /
    • 2016
  • Diffuse pollution management in Korea initiated by the Ministry of Environment (MOE) resulted to the construction of pilot facilities termed Best Management Practices (BMPs). Twelve BMPs installed for the diffuse pollution management in the Kyung-An Stream were monitored since 2006. Data on the mass loading, removal efficiency, maintenance activities, etc. were gathered and utilized to conduct the evaluation of long-term performance of BMPs. The financial data such as actual construction, design and maintenance cost were also collected to evaluate the lifecycle cost (LCC) of BMPs. In this study, most of the maintenance activity was focused in the aesthetic maintenance that resulted to the annual maintenance cost of the four BMP types was closely similar ranging from 8,483 $/yr for retention pond to 8,888 $/yr infiltration system. The highest LCC were observed in constructed wetland ($418,324) while vegetated system had the lowest LCC ($210,418). LCC of BMPs was not so high as compared with the conventional treatment facility and sewage treatment plant. On the other hand, the relationship of removal efficiency on unit cost for TSS and TN was significant. This study will be used to design the cost effective BMP for diffuse pollution management and become models for LCC analysis.

A Study on the Improvement of Construction Cost Standards for Pipe Laying and Joining Work (관 부설 및 접합공사 공사비산정기준 개선에 관한 연구)

  • Oh, Jae-Hoon;Ahn, Bang-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.675-684
    • /
    • 2020
  • To prevent safety accidents caused by aging pipe infrastructure and to maintain water quality, construction projects for water and sewage pipes are actively conducted across Korea. This study analyzed the criteria situations, site survey details, and regulation revisions related to the calculation of construction cost standards for pipe laying and joining work. The analysis showed that the major causes for revision are the unclear construction scope, limitations in implementing some pipe materials due to installation facility types, workforce focused on ordinary labor, limitations of manual laying work, and the lack of tool hire cost and machine expense-calculation criteria. Field studies were conducted to categorize the pipes according to their features, in addition to identifying the use of lifting heavy equipment and light equipment. In addition, excavation and testing work conducted in connection to pipe laying, as well as the use of skilled labor, were investigated. The current study clarified the work scope through new common items, provides an organization based on the pipe material, adjusted the workforce ratio to focus more on skilled labor, and developed grounds for calculating machine expenses. These revisions were estimated to save approximately 1.28% of the construction costs in each project according to an analysis of the construction cost impact study. truction costs in each project, according to an analysis of construction cost impact study.

Pre-treatment Characteristics of Night Soil by Microbubble (마이크로버블을 이용한 분뇨의 전처리 특성)

  • Lim, Ji-young;Kim, Hyun-sik;Park, Soo-young;Kim, Jin-Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.31-37
    • /
    • 2016
  • This study was conducted to investigate the effect of OH radicals on organic matter oxidation and suspended solids removal using microbubble as a pre-treatment technique to reduce the organic load of night soil in connection with sewage. The experiment was conducted for three months at HRT 4 hours using pressurized type microbubble generator. The mean SS removal efficiency was achieved 71%. The average removal efficiency of $TCOD_{Cr}$, TBOD, TN and TP were achieved for 51.5%, 47.9%, and 14.7% respectively, as scum and SS were removed by flotation separation. The removal efficiency of soluble organic matters were 25.0%, 17.1% for $SCOD_{Cr}$, SBOD by air microbubble supply. Soluble nitrogen and phosphorus were removed average of 11.9% and 7.4%, respectively. As s result, it was confirmed that soluble organic matters were removed by air microbubble supplied. Generated OH radicals when the microbubble was collapsed, can decompose the soluble organic matters. Therefore, The microbubble flotation process was installed at the front of night soil treatment process, it will contribute to the stable operation of the subsequent biological treatment facility by oxidation of the dissolved organic matters as well as removal of SS by flotation separation.

Developing Evaluation Index and Item for Water Environment Improvement of Gyeongin ARA Waterway (경인 아라뱃길의 물환경 개선을 위한 오염원인 평가항목 및 지표 개발)

  • Lee, Kyung-Su;Kim, Tae-Hyeong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.469-482
    • /
    • 2018
  • This research has developed the criteria and index for systematically and objectively assessing the quality of river water by fixing the various factors that affect Gyeongin ARA waterway's water quality through analysis with the Delphi Technique and analytic hierarchy program (AHP) Method. Based on the results, the highest criteria are, in order of importance, physical and environmental factors 28%, administrative factors 26%, natural fixed factors 26% and finally, cultural and social factors 20%. The three dimensions of the criteria show that for the internal physical and environmental factors, the most important are the loss of self-purification capacity, and the external factors are Gulpocheon and the sludge deposit due to Gyulhweon-weir the bridge. The facility factor in management was affected by the coagulation and waste water disposal facilities. The problem for the policy and institutional factors was seen in the regulatory area. The aquatic ecology/ point pollution source for the natural fixed factors show that it is due to the polluted water of Gulpo-cheon and the living environment/ non-point pollution source is shown through the inflow water from other rivers. Cultural and social factors show that the economical causes were due to the cargo and passenger flight operations and the external factors of having a lack of sewage treatment equipment have an importance effect. In order to estimate the order of priority through logical evidence and objectivity, future research must be continued on the evaluation indexes to measure the specific methodology and technique needed to improve the Gyeongin ARA Waterway.