• Title/Summary/Keyword: settlement behavior

Search Result 649, Processing Time 0.019 seconds

Analysis of hydraulic behavior around tunnel after application of cutoff grouting and proposing a method for estimating grouting range (차수그라우팅 적용에 따른 터널주변 수리학적 거동 분석과 그라우팅 적용범위 산정방법의 제안)

  • Joon-Shik Moon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.26 no.1
    • /
    • pp.79-89
    • /
    • 2024
  • Excessive inflow of groundwater during tunnel excavation not only affects the stability and constructability of the tunnel, but is also one of the main causes of ground settlement due to groundwater level drawdown. The most commonly applied measure against excessive groundwater inflow during tunnel excavation in soil or fractured zone is to reduce the ground permeability coefficient by injecting grout material. Generally, the grouting area is assumed to be same as the plastic zone that occurs during tunnel excavation, but injecting grout material in the area of plastic zone is appropriate only for reinforcement grouting. In order to determine the thickness of cutoff grouting, the amount of reduction in the water permeability coefficient due to the application of cutoff grouting must be considered. In this study, a method for estimating the range of cutoff grouting considering the reduction in permeability coefficient was mathematically derived and evaluated through computer numerical analysis.

Practical Consolidation Analysis and Back Analysis for Draainage-Installed Compressible Deposits (배수재가 설치된 압축성 지반의 효율적인 압밀해석 및 역해석)

  • 김윤태;이승래
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.09a
    • /
    • pp.175-181
    • /
    • 1994
  • In order to accelerate the rate of consolidation settlement and to gain a required shear strength for a given soft clay deposit, the preloading technique combined with a vertical drainage system has been widely applied. In this study, the theory of axisymmetric concolidation, which considers the variation of compressibility and permeability during the consolidation process, has been developed. Smear and well resistance effects are also considered. Furthermore, several back-analysis schemes such as simplex method, BFGS method, and ADS have been adopted in the axisymmetric consolidation program(AXICON). The measured data in the first stage of consolidation are utilized to predict the subsequent consolidation behavior.

  • PDF

Piled Raft Foundations (말뚝지지 전면기초)

  • Kwon, Oh-Kyun;Lee, Whoal
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.11a
    • /
    • pp.102-117
    • /
    • 2002
  • The general design practice for piled footings is based on the assumption that the piles are free-standing, and that all the external loads are carried by the piles, with any contribution of the footing being ignored. This approach is not reasonable, because the footing itself is actually in direct contact with the soil, and thus carries a significant fraction of the loads. In the case of not considering the bearing capacity of footing, the bearing capacity of group piles can be evaluated conservatively in the designing the group piles. There are a number of reasons why the idea of piled raft design with considering the capacity of footing has not become widely used. One of the reasons is the lack of reliable calculation methods for estimating the behavior of piled raft. In this study the bearing capacity, settlement, load distribution, etc. of piled raft footing are studied.

  • PDF

A Study on the Conclusion Bearing Capacity ol Polluted Soils Owing to Difference of Water Content (함수량이 다른 오염지반의 지지력 결정에 관한 연구)

  • 안종필;박상범;박경호
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.481-488
    • /
    • 1999
  • This study, investigates the existing theoretical backgrounds in order to examine the behavior of lateral flow owing to the plasticity of soils when unsymmetrical surcharge is worked on polluted soils by the increase of water content compares and analyzes the results measured through model tests. Unsymmetrical surcharge is increased at regular intervals to soil tank made up the polluted soils and then the amounts of settlement, lateral displacement and upheaval are observed. Critical surcharge was decided q$\sub$cr/= 3.42 C$\sub$u/ similar to those had proposed Terzaghi and JHI, and the value of ultimate capacity was decided q$\sub$ult/= 7.71 C$\sub$u/ similar to that of Tschebotarioff and JHI.

  • PDF

In-Situ Behaviors of Steel Frame-type Retaining Walls (조립식 강재틀 옹벽의 현장적응성 분석)

  • 박종배;임해식;박용부;나승민;정형식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.06a
    • /
    • pp.93-101
    • /
    • 2003
  • Steel frame-type retaining walls(SFRW) are constructed by on site bolting of prefabricated steel frames and internal filling of materials such as rocks with the size of 150-300mm. Easy & fast construction, superior drainage performance and structural performance to rigorous site conditions are some of the merits of applying the SFRW to various construction sites. After the development of the structural details, a test construction of SFRW, with the height of 6m and 30m in length, was carried out at an apartment site. After completion, several months of monitoring was carried out on the structure to check displacement, tilting, settlement, soil pressures and drainage characteristics. The results of the structural behavior of SFRW along with its construction methods are presented in the paper.

  • PDF

Study for the Pertinent Scheme of the One Dimensional FDM Analysis (1차원 압밀 F.D.M 해석의 최적도식(Scheme) 연구)

  • 김팔규;김지호;구기욱;류권일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.631-638
    • /
    • 2000
  • Pioneering work by Terzaghi imparted scientific and mathematical bases to many aspects of this subject and many people use this theory to measure the consolidation settlement until now. In this paper, Finite Difference Methods for consolidation are considered. First, it is shown the stability criterion of Explicit scheme and the Crank-Nicolson scheme, although unconditionally stable in the mathematical sense, produces physically unrealistic solutions when the time step is large. it is also shown that The Fully Implicit scheme shows more satisfactory behavior, but is less accurate for small time steps. and then we need to decide what scheme is more proper to consolidation. The purpose of this paper is to suggest the pertinent scheme to consolidation.

  • PDF

Displacement Behavior of Tunnel under Bridge Abutment due to Supporting Systems (교량기초 하부에 위치한 터널의 지보방법에 따른 변위거동)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jeong, Gil-Soo;Kim, Seung-Ryul
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.613-620
    • /
    • 2005
  • This research is experimental paper to prepare the structural safety of the upper bridge for support type on tunnel and the effect of settlement. Unit weight test and uni-axial compression test have been performed to simulate the physical property of foundation on the tunnel. Tunnel model of slip form type for centrifuge model has been developed to performed the tunnel excavation while field stress is activated. And the support type of tunnel such as umbrella arch method and large diameter steel pipe reinforce method has been tested for the centrifuge model. After the analysis of experiment, results show that internal displacement of large diameter steel pipe reinforce method is smaller than that of the umbrella arch method.

  • PDF

Stabuility Evaluation Methods of Soft Clay under Embankment by Field Monitoring (현장계측에 의한 연약지반 성토의 안정관리 기법)

  • 강예묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.92-103
    • /
    • 1999
  • A series of field tests were performed to suggest a rational method for the stability evaluation of soft clay. The behavior of settlement-displacement obtained by field monitoring system was used to compare and analyze with various stability evaluation methods, and to investigate the applicability of the methods for stability evaluation of soft clay. The limit equilibrium method, numerical analysis and field monitoring methods were used to analyze the stability evaluation. The horizontal displacement was abruptly increased when physicla properties of soft clay reached its maximum values and therefore, the values of these properties could be used to the fundamental data for stability evaluation. The evaluation of the stability of clay embankment was suggested to use inclination of ccrve rather than critical line, and the minimum satey factor of 1.2 or larger for natural clay was recommeded . Therefore, the evaluation of short term stability of soft clay could be effectively peformed with the hypefrbolic model and the field monitored data.

  • PDF

Behavior of polymer columns in soft clayey soil: A preliminary study

  • Arasan, Seracettin;Akbulut, Rahim Kagan;Isik, Fatih;Bagherinia, Majid;Zaimoglu, Ahmet Sahin
    • Geomechanics and Engineering
    • /
    • v.10 no.1
    • /
    • pp.95-107
    • /
    • 2016
  • Deep soil mixing with cement and cement-lime mixtures has been widely used for decades to improve the strength of soils. In this study, small-scale laboratory model tests of polymer columns in soft clayey soil were conducted to evaluate the feasibility of using various polymeric compounds as binders in deep soil mixing. Floating and end bearing polymer columns were used to examine the load-settlement relationship of improved soft clayey soils for various area replacement ratios. The results indicate that polymer columns show good promise for use in deep mixing applications.

Experimental study of the effect of the glass fibers on reducing collapse of a collapsible soil

  • Bakir, Nassima;Abbeche, Khelifa;Panczer, Gerard
    • Geomechanics and Engineering
    • /
    • v.12 no.1
    • /
    • pp.71-83
    • /
    • 2017
  • Collapsible soil presents a porous unsaturated structure, its sudden settlement after humidification, without supplementary charge, can be of a big nuisance for the foundations and therefore for the constructions built on it. To improve its structure and limit its instability, samples of laboratory reconstituted soil, with different percentages of water contents and compacted at different compaction energies, were treated with glass-fiber. The study of the mechanical behavior was performed by oedometer tests. The microstructure was explored by the Scanning Electron Microscope (SEM). The results obtained show clearly the efficiency of the treatment with glass fiber on reducing the collapsibility of such soil.