• Title/Summary/Keyword: set-up effect

Search Result 1,229, Processing Time 0.039 seconds

Study on Prediction of Performance with Design Variables of Solar-Assisted Still Using Waste Heat from Diesel Generator (디젤 발전기 폐열을 활용한 태양열원 해수담수기의 설계변수에 따른 성능 예측에 관한 연구)

  • Jang, Hyun;Yi, Chung Seob;Suh, Jeong Se;Jeong, Kyoung Yul;Park, Change Dae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.12
    • /
    • pp.1061-1068
    • /
    • 2013
  • This study predicts distillate productions according to design variables by numerical analysis when the waste heat from a diesel generator is added to the solar-assisted still proposed in a previous study. Mathematical models were set up in reference to previous studies, and the amount of heat exchange from the waste heat recovery pipe was considered. To ensure the reliability of numerical analysis, the result was compared with that of a previous study and then, the distillate productions according to design variables were obtained by the analysis model. The results were found to generally be in agreement, and the increasing amount of distillate production of the still with the added waste heat was confirmed. In addition, the optimal value of the tilt angle of glass cover and the number of cells were determined by numerical analysis.

Effect to Fillers for FKM (Fluorocarbon rubber) Gasket in Fuel Cell Stack (연료전지 스택 가스켓용 불소고무에 있어 충전제 종류에 따른 영향)

  • Hur, Byung-ki;Kang, Dong-gug;Yoo, Il-hyuk;Lee, Dong-won;Seo, Kwan-ho;Park, Lee-soon
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.86-91
    • /
    • 2008
  • The rubber was compounded with carbon black and silica series-filler to examine the effects of the various rubber fillers on a gasket material's suitability and fuel cell stack conclusion. The evaluation of a long term heat resistance and oil resistance of the mixed rubber material was performed considering at the drive environment of PEMFC. Test results of compression set for the most influencing property of gasket showed that it was about less than 15% at long term of up to 1000 h. In this experiment, FEM analysis is carried out about the rubber material's properties depending on each filler and the stress which is produced when a gasket is contracted by using various filler. Sealing force was expected to maximum 2.5 MPa from minimum 0.2 MPa by using FEM (finite element method) at stacking gasket to gasket.

Effectiveness of herbal acupuncture of Carthami semen(Honghwa) vs its cotreatment with spiral taping for the treatment of acute low back pain : A randomized controlled trial (급성요통의 치료에 홍화약침과 홍화약침+첩대요법의 비교연구 : 무작위 대조군 임상실험)

  • Jeong, Min-Su
    • Journal of Pharmacopuncture
    • /
    • v.5 no.2
    • /
    • pp.25-38
    • /
    • 2002
  • Spiral taping shows great effectiveness in relieving musculoskeletal pains. The purpose of this research is to compare effectiveness of herbal acupuncture of Carthami semen(Honghwa) vs its cotreatment with spiral taping for the treatment of acute low back pain. The target patients were those who satisfied with all of the following conditions. 1. Those who suffered from acute low back pain but without past history of the pain in the last six weeks. 2. The pain wasn't radiated to the lower limbs and were without any neurotic symptoms. A computerized randomization was used to set the patients in two groups. The control group was consisted of 41 patients and treated with herbal acupuncture. The experimental group was consisted of 49 patients and treated with spiral taping as well as herbal acupuncture. The treatment was given two times a week and the nurses measured the ROM and VAS evaluation before every treatment. The patients wrote ODI by themselves before the first treatment and after the 3rd treatment. After three months, an interview of the patients' condition through a follow up survey was done. In terms of acute low back pain in both the control group and experimental group, significant treatment effects were found by assessing VAS, ROM and ODI. By comparing the control group and the experimental group, there was more significant improvement in the experimental group than the control group of VAS and ROM, but no significant effect was found between the groups of ODI. This study shows that the herbal acupuncture of Carthami Semen plays a significant role in relieving acute low back pain. It also shows that spiral taping of the experimental group was more highly effective. As a result, spiral taping can be used with acupunture of Carthami Semen for a highly effective treatment for acute low back pain.

Transverse Vibration Analysis of the Deploying Beam by Simulation and Experiment (시뮬레이션과 실험을 통한 전개하는 보의 횡 방향 진동 분석)

  • Kim, Jaewon;Zhu, Kefei;Chung, Jintai
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.12
    • /
    • pp.866-873
    • /
    • 2015
  • The transverse vibration of the deploying beam from rigid hub was analyzed by simulation and experiment. The linear governing equation of the deploying beam was obtained using the Euler-Bernoulli beam theory. To discretize the governing equation, the Galerkin method was used. After transforming the governing equation into the weak form, the weak form was discretized. The discretized equation was expressed by the matrix-vector form, and then the Newmark method was applied to simulate. To consider the damping effect of the beam, we conducted the modal test with various beam length. The mass proportional damping was selected by the relation of the first and second damping ratio. The proportional damping coefficient was calculated using the acquired natural frequency and damping ratio through the modal test. The experiment was set up to measure the transverse vibration of the deploying beam. The fixed beam at the carriage of the linear actuator was moved by moving the carriage. The transverse vibration of the deploying beam was observed by the Eulerian description near the hub. The deploying or retraction motion of the beam had the constant velocity and the velocity profile with acceleration and deceleration. We compared the transverse vibration results by the simulation and experiment. The observed response by the Eulerian description were analyzed.

The Effect on the Tension Trapezius Muscle of the Height Keyboard Computer (작업대 높이가 승모근의 근긴장도에 미치는 영향)

  • An, Chang-Sik;An, Yun-Hee;Lee, Myeong-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.6
    • /
    • pp.67-75
    • /
    • 2006
  • Purpose: Many kinds of musculoskeletal disease and symptom are caused by the longtime computer works. However, trapezius muscle tonus has not been established in regarding to keyboard height during typing. Therefore, this study is to evaluate the relationship between trapezius muscle tonus and the height of keyboard while typing, controling for the postures of neck, Lumbar, cervical vertebra. Methods: The experimental height of keyboard was set at elbow height, 3cm higher, 6cm higher, 9cm higher, than elbow. We studied trapezius tonus with the mean value for 2 minutes by EMG in 15 males and 15 females worker of hospital in seoul, who did not have a history of muscle disease, neurological signs, nerve damage. Results: In this experimental, as the height of the keyboard went up, the trapezius tonus significantly increased with shoulder abduction of brachium. Second, right and left trapezius tonus appeared similar while typing. Third, the best height that release the trapezius tonus the was as high as elbow and 3cm higher than elbow. Conclusion: With these above results, we suggest that the appropriate height of keyboard during typing to release the trapezius tonus most is the height of the elbow and 3cm higher than elbow. The study has important implications for focusing on the height of VDT worktable and complaining of a pain by oneself which are useful to establish a method of prevention of musculoskeletal disorder in work in the future.

  • PDF

An Experimental Study for Reduction of Sedimentation Deposit in Combining Junction Manholes (합류맨홀에서의 유사퇴적 저감을 위한 실험적 연구)

  • Kim, Jung-Soo;Kim, Kyoung-Beom;Yoon, Sei-Eui
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.8
    • /
    • pp.767-782
    • /
    • 2012
  • Accumulation of sediment within pipelines, manholes, and other components of urban sewer systems can have a bad influence on sewerage arrangements, such as the resistance of the passage of flows, the cause of urban flooding and the premature operation of combined sewer overflows, and the inevitable pollution of watercourses. Therefore, it is necessary to understand the movements and sedimentation of sediment loads in combining junction manholes by experiments. In this study, hydraulic experimental apparatus which can change the manhole shapes (square, circle) were installed to measure deposited sedimentation quantity. The quantity of deposited sediment loads was measured by different conditions, for instance, the inflow conditions of sediment (continuous and certain period), the amount of inflow sediment, and the variation of inflow pipe of sediment. The combining junction manhole that was set up a inclined benching have the considerable effect of reduction of sedimentation in manholes without apropos of the change of manhole shapes. Therefore, the improved manhole could be increased the drainage capacity of sewerage arrangements in urban sewer systems.

Problems and Improvement Methods of Cadastral Confirmation Surveying (지적확정측량의 문제점과 개선방안)

  • Mun, Seung-Ju
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.313-323
    • /
    • 2016
  • Recently, "Cadastral Confirmation Surveying" has been established to promote efficiently and systematically its work. To do so, it is necessary that cadastral control point should be set up and transverse grid coordinates should be determined for high accuracy and boundary restoration based on the cadastral control point. This study expects the potentially institutional problem of detail surveying and the limitation of Network-Real Time Kinematic, introduced to measure the cadastral control point first in the issued regulation, and thus presents the improvement and the management of the block boundary of larger parcel as solutions. This can be applied promptly, when the location difference of ground and border, registered in cadastral record for quake and others, occurs. Thus, the public confidence of cadastral record may become higher and relevant social costs get reduced by the advanced prevention effect of boundary dispute, which represents much to the management of cadastral institution. Provided cadastral confirmation surveying is implemented with the management of the block boundary of larger parcel, proposed in this study.

A Parameter Study of Stuctural Respanse Model in Flexible Pavement Substucture Layers (아스팔트 포장하부구조 층모델 결정에 관한 연구)

  • Choi, Jun-Seong;Seo, Joo-Won
    • International Journal of Highway Engineering
    • /
    • v.5 no.4 s.18
    • /
    • pp.13-22
    • /
    • 2003
  • Several design methods from overseas are employed without considering different conditions such as material properties, climate, and traffic condition in this country. Therefore, there are limitations in application. Therefore, new pavement analysis system which is able to design a pavement efficiently and economically should be set up. In this study, 243 probable sections are classified depending on values of layer thickness and elastic modulus, and the effect of load types for the probable sections are analyzed. The section showing larger load distribution is chosen for analysis. As a result of sensitivity, a layer thickness has more influence on pavement than an elastic modulus does. The stress distribution of FWD test load is larger than that of circular load. This study compares outputs between nonlinear elastic model and linear elastic model. Based on the result, this study finds nonlinear elastic model considering stress condition in the ground is recommended for subbase.

  • PDF

Cyclic Creep Model for the Deflection Calculation of Reinforced Concrete Flexural Members under Fatigue Loads (피로하중을 받는 철근콘크리트 휨부재의 처짐산정을 위한 반복크리프 모델)

  • 오병환;김동욱
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.415-422
    • /
    • 2001
  • The present paper focuses on the development of a realistic analysis model for the deformation calculation of reinforced concrete beams subjected to fatigue loadings. The proposed model considers the effect of cyclic creep, which arises from the repeated loading, to calculate the deformation of reinforced concrete beams. A comprehensive experimental program has been set up to identify the deformation accumulation of reinforced concrete beams under repeated loadings. The major test variables were the concrete compressive strength and the magnitude of fatigue loads. The model was calibrated from the present test results. The proposed model allows more realistic analysis of reinforced concrete beams under fatigue loads, especially deformation accumulation of such beams.

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.