• Title/Summary/Keyword: serviceability evaluation

Search Result 193, Processing Time 0.024 seconds

Serviceability Evaluation of Slim Composite Floor System (슬림 합성보 바닥시스템의 사용성 평가)

  • Eun, Hee-Chang
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.63-70
    • /
    • 2008
  • Slim floor construction is becoming used throughout many countries. It combines the advantages of flat slab construction with significant inherent resistance to fire. The slim floor system with web openings leads to the reduction of its self-weight. Although the system has enough strength and stiffness, it is necessary to evaluate and improve the effects of dynamic vibration to be able to annoy the residents. Thus, this study evaluates the serviceability of vibration effects based on the dynamic test of five slim composite beams. Based on the experimental results, the initial stiffness and natural frequency of all specimens exhibit the similar trend regardless of the opening and the shape of cross section. The decrease in natural frequency is deeply related to the reduction in the stiffness of specimens and thus, it can be concluded that the damage of slim composite floor can be detected by the measurement of natural frequency instead of the load-carrying capacity and the stiffness.

Vibration evaluation of building floors using Preflex composite beams (프리플렉스 합성보를 적용한 기존 건물 바닥구조의 진동평가)

  • 경재환;임지훈;김희철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.194-201
    • /
    • 2001
  • The dynamic characteristic of the building using preflex composite beams is a low natural frequency due to long span. Therefore, both vibrational acceleration and the characteristic of natural frequency damage to people using the building, This study estimates a vibrational acceleration based on walking and natural frequency in five kinds of building. Recently, using methods of evaluating a serviceability are based on JIA, AISC, Eurocode, CSA, DIN and ISO. ed. The result of this study is content with foreign regulations and serviceability. However, considering of these results, the method of evaluating serviceability should be developed in the future.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Park, Sun-Joon;Kang, Sung-Hoo;Kim, Bo-Hwoan;Kim, Seung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.781-786
    • /
    • 2009
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90m span, width of 5.5m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "Level C, Strongly Perceptible" and "Level B, Disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

  • PDF

Vibration Serviceability Evaluation of Prestressed Concrete Girder Bridge (공용중인 PSC 거더 교량의 진동사용성 평가)

  • Kang, Sung-Hoo;Kim, Bo-Hwoan;Park, Sun-Joon;Kim, Seung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.4
    • /
    • pp.331-337
    • /
    • 2010
  • The thesis shows that we gauged vibration of vehicular load regarding WPC girder bridge and researched into dynamic characteristics(natural frequency, vibration acceleration) of WPC girder bridge. By the basic of that, we researched on vibration serviceability by looking over and being compared to vibration criteria we had before. In the thesis, the gauged vibration made an analysis of vertical acceleration through FFT method and evaluated vibration serviceability about vibration sense the body feels by means of the standard of ISO assessment standard and Meister assessment standard by referring to analysis data. This research on bridge is WPC girder bridge of 90 m span, width of 5.5 m, and the experiment was gauged by a fluent which is right way and inverse way about dump truck of gross 270 kN. Acceleration was located in the middle of 1st span, 2nd span, 3rd span. As a result of appraisal standard of Meister, the vibrations of the bridge have distributed between "level C, strongly perceptible" and "level B, disturbing". Also the vibration can be attacked with unpleasant feeling. As a result of appraisal standard of ISO, from vibration influence didn't come to 60s, and reduced comfort boundary in part of most rigorous standard that such a case didn't happen.

Study on Safety Evaluation of the Half-Depth Precast Deck with RC Rib Pannel for the Flexural Behavior (리브 형상을 갖는 반단면 프리캐스트 판넬의 휨 안전성 평가 연구)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.4
    • /
    • pp.76-84
    • /
    • 2019
  • The precast pannels are used as formwork in Half-depth precast deck systems. Therefore, it has many advantages, including safe and convenient construction and reduced construction period compared to cast-in-place construction method. In half-depth precast deck systems, the bonding of precast pannels to cast-in place concrete is very important. To enhance the performance of half-depth precast deck system, it is necessary to improve the composite efficiency of the interface or increase the stiffness of the precast pannel to reduce deformation or stress on the interface. In this study, a flexural test of half-depth precast deck system was performed, in which the shear connecting reinforcement was applied to increase the bonding performance at the interface, and the rib shape precast panels were applied to improve stiffness. In addition, the safety and serviceability of these systems were evaluated. Test results show that all of specimens have the required flexural strength under the ultimate strength limit design. It was also evaluated to have sufficient safety for the serviceability of deflection and crack under the serviceability limit design.

Occupant comfort evaluation and wind-induced serviceability design optimization of tall buildings

  • Huang, M.F.;Chan, C.M.;Kwok, Kenny C.S.
    • Wind and Structures
    • /
    • v.14 no.6
    • /
    • pp.559-582
    • /
    • 2011
  • This paper presents an integrated wind-induced dynamic analysis and computer-based design optimization technique for minimizing the structural cost of general tall buildings subject to static and dynamic serviceability design criteria. Once the wind-induced dynamic response of a tall building structure is accurately determined and the optimal serviceability design problem is explicitly formulated, a rigorously derived Optimality Criteria (OC) method is to be developed to achieve the optimal distribution of element stiffness of the structural system satisfying the wind-induced drift and acceleration design constraints. The effectiveness and practicality of the optimal design technique are illustrated by a full-scale 60-story building with complex 3D mode shapes. Both peak resultant acceleration criteria and frequency dependent modal acceleration criteria are considered and their influences on the optimization results are highlighted. Results have shown that the use of various acceleration criteria has different implications in the habitability evaluations and subsequently different optimal design solutions. The computer based optimization technique provides a powerful tool for the lateral drift and occupant comfort design of tall building structures.

Burst strength behaviour of an aging subsea gas pipeline elbow in different external and internal corrosion-damaged positions

  • Lee, Geon Ho;Pouraria, Hassan;Seo, Jung Kwan;Paik, Jeom Kee
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.7 no.3
    • /
    • pp.435-451
    • /
    • 2015
  • Evaluation of the performance of aging structures is essential in the oil and gas industry, where the inaccurate prediction of structural performance can have significantly hazardous consequences. The effects of structure failure due to the significant reduction in wall thickness, which determines the burst strength, make it very complicated for pipeline operators to maintain pipeline serviceability. In other words, the serviceability of gas pipelines and elbows needs to be predicted and assessed to ensure that the burst or collapse strength capacities of the structures remain less than the maximum allowable operation pressure. In this study, several positions of the corrosion in a subsea elbow made of API X42 steel were evaluated using both design formulas and numerical analysis. The most hazardous corrosion position of the aging elbow was then determined to assess its serviceability. The results of this study are applicable to the operational and elbow serviceability needs of subsea pipelines and can help predict more accurate replacement or repair times.

An Experimental Study on Evaluation of Fatigue Safety and Serviceability for the Precast Half Deck Panel Joints (반단면 프리캐스트 판넬 이음부의 피로 안전성 및 사용성 평가를 위한 실험적 연구)

  • Park, Woo Jin;Hwang, Hoon Hee;Kwon, Nam Seung
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.50-56
    • /
    • 2019
  • Precast members have relatively good quality because they are manufactured in an environment suitable for quality control. A typical precast method in which pre-fabricated segments are assembled in the field requires a joint. Although the joint is a small part of the member, it greatly affects the behavior and quality of the structural member. In the previous study of this paper, the flexural strength of a joint, which is generally applied to half-depth precast deck systems, was verified to have higher strength than the design requirement. In addition, the proposed joint has been verified to have higher strength by reinforcing the connecting rebar. However, even if the flexural strength of the joints is sufficient, excessive deflection or lack of fatigue performance is likely to cause cracks in the half-depth precast deck system. In this study, the serviceability of the half-deck precast panel specimens with joints was evaluated and the experimental verification was conducted to evaluate the fatigue performance of the joint without connection rebar. As a result, the serviceability such as deflection and crack width was found to be higher than the design requirement in all the specimens. In the fatigue test, the fatigue effect was insignificant even in the absence of connection rebar.

Serviceability Evaluation of ZigBee Technology for Construction Applications (설문조사를 통한 ZigBee 무선통신기술의 건설산업 사용성평가에 관한 연구)

  • Shin, Young Shik;Cao, Shang;Jang, Won-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.3D
    • /
    • pp.247-258
    • /
    • 2012
  • This research evaluates the serviceability of ZigBee device that provides a potential technology to realizing the ubiquitous computing by improving the productivity and effectiveness in construction and data acquisition. Literature review was conducted in various application areas such as bridge monitoring, slope management, road management, highway traffic control. In addition characteristics and challenges in various wireless technologies are described to identify their adoptability to construction environment. Among them, ZigBee technology was selected to introduce the functionality on hardware, network, and security. Then, questionnaire survey was implemented by four different group, construction engineers, students, hardware developers, and researchers to explore the success and failure factors of ZigBee technology in construction area. The results proposes a guideline of the applicability of ZigBee technology in the area of serviceability, application area, considerations, and future direction. This paper would provide valuable information for future researches and technology development in designing the wireless sensor network applications.

Analysis of Economic Feasibility and Suitability of Highrise Buildings Using Highstrength Steel (고강도 강재를 활용한 초고층건물의 경제성 및 적합성 분석)

  • Kim, Seonwoong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • This paper aims to analyze the economic feasibility and investigate the possibility of elastic seismic design of wind-designed highrise concentrically braced frames considering change of mechanical properties of Korean steel under the strong wind and the low seismicity in Korea. To this end, first, highrise concentrically braced frames were designed considering strong wind load. And then, analyses of the economics of them were performed. The seismic performance evaluation of wind-designed highrise buildings was conducted using the response spectrum analysis procedure. Analysis results show that it is possible to save up to approximately 90% of the amount of steel on the 10% increase in steel strength without serviceability. However, with serviceability, the design sectional area of the steel with relatively high strength tends to increment considerably because of the lateral stiffness due to reduction of the inertia moment and so on. This point might apply to limitation of the steel with high tensile yield strength.