• 제목/요약/키워드: series-parallel

검색결과 966건 처리시간 0.043초

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구 (A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter)

  • 오재훈;고수현;한윤석;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

침지 및 직립 평판형 MFC 스택에서 전극연결 방식에 따른 전기발생량 비교 (Electricity Generations in Submerged-flat and Stand-flat MFC Stacks according to Electrode Connection)

  • 유재철;박영현;이태호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.589-593
    • /
    • 2016
  • 미생물연료전지(Microbial Fuel Cell; MFC)는 전기화학활성미생물로 불리는 미생물을 촉매로 이용하여, 유/무기물의 산화환원 반응을 통해서 전기에너지를 생산할 수 있는 장치이다. 단일 MFC에서 발생하는 낮은 전기생산량을 극복하기 위해, 다수의 형태의 MFC를 직렬 또는 병렬로 연결하는 방법이 연구되고 있다. 본 연구에서는 6개의 단위 막전극접합체(Separator Electrode Assembly; SEA)로 구성된 침지평판형과 직립평판형 MFC 스택을 운전하였다. 단위 MFC와 MFC 스택의 전기발생량을 비교하였으며, 이를 통해서 MFC의 최적 스택기술을 확보하기 위한 기초자료로 활용하고자 하였다. 모든 SEA가 산화전극부를 공유하고 있는 침지평판형 MFC의 경우, 직렬과 병렬을 함께 사용할 경우, 단일 연결 방식을 사용하는 것보다 전압의 손실이 더 크게 나타났으며, 단일 연결방법 중 병렬연결 하는 것이 손실을 최소화 할 수 있는 것으로 나타났다. 직립평판형 MFC의 경우, 산화전극부를 공유하고 있는 SEA만 직렬 연결할 경우에는 전압의 손실이 크게 나타났으며, 산화전극부를 공유하고 있는 SEA간에 병렬 연결 후, 병렬 연결된 SEA를 직렬연결하는 방식이 전압의 손실을 최소화 할 수 있을 것으로 나타났다.

마이크로솔더링을 이용한 정전류다이오드 회로 자외선 LED 광원모듈 제작 (Fabrication Of Ultraviolet LED Light Source Module Of Current Limiting Diode Circuit By Using Flip Chip Micro Soldering)

  • 박종민;유순재;카완 안일
    • 한국전기전자재료학회논문지
    • /
    • 제29권4호
    • /
    • pp.237-240
    • /
    • 2016
  • The improvement of irradiation intensity and irradiation uniformity is essential for large area and high power UVA light source application. In this study, large number of chips bonded by micro soldering technique were driven by low current, and current limiting diodes were configured to supply constant current to parallel circuits consisting of large number of series strings. The dimension of light source module circuit board was $350{\times}90mm^2$ and 16,650 numbers of 385 nm flip chip LEDs were used with a configuration of 90 parallel and 185 series strings. The space between LEDs in parallel and series strings were maintained at 1.9 mm and 1.0 mm distance, respectively. The size of the flip chip was $750{\times}750{\mu}m^2$ were used with contact pads of $260{\times}669{\mu}m^2$ size, and SAC (96.5 Sn/3.0 Ag/0.5 Cu) solder was used for flip chip bonding. The fabricated light source module with 7.5 m A supply current showed temperature rise of $66^{\circ}C$, whereas irradiation was measured to be $300mW/cm^2$. Inaddition, 0.23% variation of the constant current in each series string was demonstrated.

2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성 (Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel)

  • 박형민;조용선;최효상;오금곤;한태희;임성훈;황종선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

직병렬보상방법에 의한 초고압장거리송전선로의 보상효과분석 (The Effect Analysis of Series and Shunt Compensation Schemes for EHV Long Transmission Lines)

  • 정재길;강영묵
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.224-227
    • /
    • 1997
  • This study discuss two subjects : maximization of transmission capability and regulation of voltages along line within the permissible bounds. Series and parallel line compensation methods have been applied for those purposes using capacitors and reactors. In this paper, the effect of series and shunt line compensation for symmetrical line is analyzed. The results obtained in this paper can be applied 765kV class EHV transmission system.

  • PDF

병렬 다공판 시스템의 흡음성능에 관한 연구 (A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems)

  • 허성춘;임정빈;노승남;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.902-907
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and the number of perforated plate. The sound absorbing performances of parallel and series perforated plate systems are compared and discussed from a standpoint of frequency bandwidth with sound absorption. The proposed approach is further extended to the parallel double layer perforated plate system.

  • PDF

2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구 (A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure)

  • 이우철;유동상
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.27-34
    • /
    • 2005
  • 본 논문에서는 2개의 컨버터 구조를 갖는 삼상 계통 연계형 UPS에 대하여 연구한다. 삼상UPS시스템은 2개의 능동 전력 보상기 구조로 이루어져 있다. 하나는 직렬형으로 .전원전압과 동상의 전압원으로 동작하여 전원전압의 변동, 왜곡시에도 정현파 전원전류와 고역률을 갖도록 동작한다. 병렬형은 전원전압과 위상을 맞춘 종전의 정현파 전압원으로 동작하여 부하에 안정되고 낮은 THD를 갖는 정현파 전압을 공급한다. 본 논문에서는 직렬형, 병렬형 능동보상기에서 전원전압의 크기에 따라 충전 방법에 대하여 제시한다. 종전의 계통 연계형 UPS는 DC 충전과 출력전압을 동시에 제어하였는데, 2개의 컨버터 구조를 갖는 UPS 시스템에서는 직렬형 보상기도 DC 충전을 할 수 있어 직렬형과 병렬형을 사용한 충전 알고리듬을 연구할 필요가 있다. 따라서 DC link단의 전압을 안정시켜 본래의 직렬형, 병렬형 구조의 보상기의 안정성 향상에 기여할 수가 있다. 제안된 방법의 타당성은 시뮬레이션과 실험 결과를 통하여 입증된다.