• Title/Summary/Keyword: serial test

Search Result 343, Processing Time 0.037 seconds

Automatic Color Recognition System for Stockigt Sizing Test (I) - Bias of Stockigt sizing test based on observer's subjectiveness - (스테키히트 시험용 자동 발색 인지 시스템 개발을 위한 기초연구(I) - Stockigt 사이즈도 시험법에 영향을 주는 요인 분석 -)

  • 김재옥;김철환;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • One of the most frequently used method for measurement of the degree of sizing (viz., hydrophobicity) is the Stockigt test. However, the Stockigt test was influenced by various factors such as dropping height, dropping amount, dropping speed and viewing angle. The resultant data of the sizing degree on the same specimen also varied according to different testers. Thus, the Stockigt test should be modified to be regarded as a highly reliable and reproducible standard method. For modifying the Stockigt test, it was required to quantify red coloration by reaction between 1% ferric chloride and 2% ammonium thiocyante during Stockigt testing. The cameras capturing the serial images during the red coloration process were the CMOS (Complementary Metal Oxide Semiconductor)-type and CCD (Charge Coupled Device)-type cameras. For measurement based on KS M 7025, the CCD-type camera must be used due to its high resolution, and on the other hand, for measurement based on Tappi Useful Method 429, the CMOS-type camera may be used owing to its low resolution. It was needed to covert the RGB values of a droplet image into HSV(Hue, Saturation, and Value) values because the human eyes are much closer to HSV than RGB. Among HSV values, the Hue value was accepted as the most reliable index consistent with the red coloration process by excluding the surrounding conditions such as light, tester's movement etc.

5MW Class Gas Turbine Engine Test Cell (5MW급 발전용 가스터빈 엔진 성능시험 설비)

  • Nam, Sam-Sik;Song, Ju-Young;Kim, Sung-Hyun;Lee, Ki-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.339-342
    • /
    • 2010
  • Doosan Heavy Industries & Construction Co., Ltd. constructed a gas turbine engine test cell to verify operating characteristics and design parameters of 5MW class gas turbine engine for power generation under developing. Engine test cell was designed to satisfy critical requirements to scrutinize all performance parameters of the engine with safe and reliability in accordance with design specification. As the test cell developed can effectively reproduce engine operation conditions covering from start-up to maximum power condition, it can be utilized to make a continuing design improvement of the engine based on practical test data at full stretch. Moreover, it is expected to be serviceable to develop derivative engines and be utilized to put them into serial production and contribute to a competitiveness reenforcement as a gas turbine engine manufacturer.

  • PDF

Parallelization of CUSUM Test in a CUDA Environment (CUDA 환경에서 CUSUM 검증의 병렬화)

  • Son, Changhwan;Park, Wooyeol;Kim, HyeongGyun;Han, KyungSook;Pyo, Changwoo
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.7
    • /
    • pp.476-481
    • /
    • 2015
  • We have parallelized the cumulative sum (CUSUM) test of NIST's statistical random number test suite in a CUDA environment. Storing random walks in an array instead of in scalar variables eliminates data dependence. The change in data structure makes it possible to apply parallel scans, scatters, and reductions at each stage of the test. In addition, serial data exchanges between CPU and GPU are removed by migrating CPU's tasks to GPU. Finally we have optimized global memory accesses. The overall speedup is 23 times over the sequential version. Our results contribute to improving security of random numbers for cryptographic keys as well as reducing the time for evaluation of randomness.

Usefulness of interferon-γ release assay for the diagnosis of latent tuberculosis infection in young children

  • Yun, Ki Wook;Kim, Young Kwang;Kim, Hae Ryun;Lee, Mi Kyung;Lim, In Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.59 no.6
    • /
    • pp.256-261
    • /
    • 2016
  • Purpose: Latent tuberculosis infection (LTBI) in young children may progress to severe active tuberculosis (TB) disease and serve as a reservoir for future transmission of TB disease. There are limited data on interferon-${\gamma}$ release assay (IGRA) performance in young children, which our research aims to address by investigating the usefulness of IGRA for the diagnosis of LTBI. Methods: We performed a tuberculin skin test (TST) and IGRA on children who were younger than 18 years and were admitted to Chung-Ang University Hospital during May 2011-June 2015. Blood samples for IGRA were collected, processed, and interpreted according to manufacturer protocol. Results: Among 149 children, 31 (20.8%) and 10 (6.7%) were diagnosed with LTBI and active pulmonary TB, respectively. In subjects lacking contact history with active TB patients, TST and IGRA results were positive in 41.4% (29 of 70) and 12.9% (9 of 70) subjects, respectively. The agreement (kappa) of TST and IGRA was 0.123. The control group, consisting of non-TB-infected subjects, showed no correlation between age and changes in interferon-${\gamma}$ concentration after nil antigen, TB-specific antigen, or mitogen stimulation in IGRAs (P=0.384, P=0.176, and P=0.077, respectively). In serial IGRAs, interferon-${\gamma}$ response to TB antigen increased in IGRA-positive LTBI subjects, but did not change considerably in initially IGRA-negative LTBI or control subjects. Conclusion: The lack of decrease in interferon-${\gamma}$ response in young children indicates that IGRA could be considered for this age group. Serial IGRA tests might accurately diagnose LTBI in children lacking contact history with active TB patients.

Implementation of two wire RS232C Serial Communication Interface using CSMA protocol (충돌검지 다중접속 프로토콜에 의한 2선식 RS232C 직렬통신 인터페이스 구현)

  • 한경호;최천원
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.3
    • /
    • pp.11-17
    • /
    • 2003
  • In this paper, we implemented 2-wire (data gnd) RS232C serial communication interface by applying the Collision Sensing Multiple Access(CSMA) Protocol. The transmitting and receiving wires of RS232C pert are connected together by the interface circuit forming data wire without hardware modification On two-wired common channel connection simultaneous transmission Don mere than two hosts causes data collision. The collision is detected by loop-back test of transmission data comparing with the fed back data to detect the data distortion. Various models are adopted to reduce the probability of retransmitted data collision and experiments show the performance of each cases. Due to allowing multiple hosts to be accessed through the common communication channel with minimum circuit addition the result of this paper can be easily applied for conventional RS232C instruments and machines to connect to the single data communication line.

The Effect of Line Dance Program on Oxygen Saturation and Happiness of Elderly (라인댄스 프로그램이 노인의 산소포화도와 행복정도에 미치는 영향)

  • Shin, Myeong Gi;Min, Soon;Seo, Min Jeong;Lee, Young Rong
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose: The research was to investigate the effect of line dance programs on oxygen saturation level and happiness of elderlies. Methods: Researchers had conducted a series of test to measure peripheral blood vessel oxygen saturation level, pulse and happiness level of 47 elderlies from the D district of G city. Collected data were analyzed with ${\chi}^2$-test and independent t-test, equipped with SPSS WIN 17.0. Results: As a result of serial tests, Pre-test and Post-test of line dance performance showed that oxygen saturation of the Experimental group had significant increase following the program and happiness of the Experimental group also had significant increase following the program. Conclusion: In conclusion, with many advantages such as its easiness to access and emulate as well as its ubiquitousness as an aerobic exercise, line dance cannot only be very beneficial to cardiovascular function and relation of elderlies, but also to emotional and psychological effect, considered as a great breakthrough to improve comprehensive well-being in both physical and mental aspects.

A Design and Fabrication of Test Equipment for Airborne Tracking Radar Test (항공기용 추적레이더 시험을 위한 시험장비의 설계 및 제작)

  • Yoon, Seung-Gu;Park, Seung-wook;Kwon, Jun-Bum;Jung, Man-Seek
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.352-361
    • /
    • 2017
  • This paper proposes a design and fabrication of the test equipment that is implemented as a part of the airborne tracking radar inspection under the environment of indoor simulation. This test equipment provides controlling the operation status of airborne tracking radar and replicating the velocity and range information of target by generating a variety of target signal. This is mainly composed of radar operation controller, target signal generator, horn antenna driving devices. Radar operation controller is able to perform the controlling of radar operation mode and monitoring in real time by serial communication. Target signal generator is generated doppler signal and range delayed signal using virtual target of RF-band. Horn antenna driving devices perform a role of target simulating exercise. In the end, the performance is demonstrated using experiment results of test equipment for airborne tracking radar.

Operation Test of Control Element Drive Mechanism Using a Power Controller (전력제어기를 이용한 제어봉 구동장치 동작시험)

  • Kim, Choon-Kyung;Lee, Jong-Moo;Jeong, Soon-Hyun;Cheon, Jong-Min;Kweon, Soon-Man
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.741-743
    • /
    • 2004
  • In this paper, we describe a Control Element Drive Mechanism(CEDM) operation test using a Power Controller. By testing, we can catch the mechanical and electrical characteristics of CEDM and obtain the information about the improvement of CEDM and the design of CEDM power cabinet. The power controller for CEDM introduced in this paper can input firing angles directly into gate drive circuits of thyristors so that this method can be used to derive the maximum and minimum values of firing angles within available limits for a 3-phase half-wave rectifier. Angle inputs help us understand each coil's response characteristics. Since this power controller generates a serial sequence for CEDM insertion and withdrawal operations, we may judge whether CEDM works correctly as expected or not in each phase of a step movement.

  • PDF

A Case of Pericarditis Associated with Mycoplasma and Salmonella co-Infection (마이코플라즈마 감염과 장티프스가 병발된 심낭염 1례)

  • Koo, Gyo-Dang;Ahn, Seok-Hee;Kim, Ho-Soo;Cho, Byoung-Soo;Cha, Sung-Ho
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.1
    • /
    • pp.155-159
    • /
    • 1997
  • We had experienced a case of pericarditis associated with Mycoplasma and Salmonella co-infection. This 5-year old boy presented with high fever and generalized tonic-clonic seizure. The diagnosis was based on the markedly increased serial titer of Widal test and cold agglutinin with Mycoplasma indirect hemmagglution test during hospitalization. The electrocardiogram revealed P-R interval prolongation and an echocardiogram revealed moderate pericardial effusion. The patient treated with ceftriaxone and erythromycin for 2 weeks, and responded to the treatment well. We report this case with brief review of the related literatures.

  • PDF

Ageing evaluation of electrolytic capacitor for dc-link (직류 평활용 전해 커패시터 노화 평가)

  • Lee, Seung-Hee;Lee, Jin-Hee;Lee, Chi-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.634_635
    • /
    • 2009
  • Large aluminium electrolytic capacitors are widely used in inverter systems for smoothing dc-link voltage. If capacitors in dc-link are deteriorated by ageing, dc-link voltage is fluctuated by lessened capacitance and their bodies are heated by raised ESR(equivalent serial resistance) and finally system faults can be occurred. In this paper, on-load ageing test method of electrolytic capacitor in inverter system is proposed and test results are shown.

  • PDF