• Title/Summary/Keyword: separation efficiency

Search Result 1,116, Processing Time 0.028 seconds

Bubble Adsorptive Separation of CuS Precipitates (CuS 침전의 기포흡착분리에 관한 연구)

  • Shin, Jeong Ho;Park, Kyung Kee;Jeong, Kap Seop;Lee, Geun Hee
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.20-27
    • /
    • 1998
  • The characteristics of the bubble adsorptive separation of CTAB(cetyltrimethylammonium bromide) and CuS precipitates was investigated. The Langmuir adsorption equation was adequate at very low concentration of CTAB, and the adsorption heat was determined from the batch analysis considering the bulk liquid accompanied between bubbles. The adsorption mechanism was explained with the collision adsorption between bubbles and precipitate particles. The optimum concentration ratio of (CTAB) to (CuS) for adsorptive separation was 0.1 and coincided with the ratio for the coagulation of particles. The collection efficiency was depended on pH and CTAB concentration but independent of the air flow rate, and the maximum efficiency was 0.0002. The selective separation of ZnS from the mixture of Cu-Cd-Zn sulfides was obtained by the bubble adsorption with CTAB.

  • PDF

Separation of Bacteria Using Capillary Electrophoresis (모세관 전기영동을 이용한 박테리아의 분리)

  • Moon, Byoung-Geoun;Choi, Kyu-Seong;Lee, Sang-Chun;Kim, Yong-Seong
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.2
    • /
    • pp.144-150
    • /
    • 2004
  • Various experimental factors that affect the separation of bacteria were investigated using capillary electrophoresis. At different buffer concentrations, gram-positive bacteria and gram-negative bacteria showed somewhat different migration behavior under high electric filed. The separation efficiency was also investigated as a function of concentration of bacterium injected into the capillary. In order to separate bacteria as the difference of size and shape, water soluble polymers such as poly(ethylene)oxide (PEO), polyvinylpyirrolidone (PVP), and dextran were studied. PEO, which is more flexible and has lower steric hinderance, showed the best separation efficiency. The mixed bacteria sample of Micrococcus lysodeikticus as gram-positive bacteria and Aerobacter aerogenes as gram-negative bacteria were successfully analyzed with PEO.

Optimizing of Coagulation and Solid-Liquid Separation Conditions Using Aluminum Sulfate and Poly-Aluminum Chloride Coagulants from Brine Wastewater Discharged by the Epoxy-resin Process (에폭시수지 공정에서 발생되는 고염 폐수로부터 황산알루미늄과 PAC 응집제를 이용한 응집/고액분리 조건 최적화)

  • Lee, Chang-Han;Kim, Yu-Jin;Moon, Sung-Hyun;Kwon, Sung-Hun;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.31 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • In this study, solid-liquid separation conditions for coagulation and sedimentation experiments using inorganic coagulant (aluminum sulfate and Poly-Aluminum Chloride (PAC)) were optimized with brine wastewater discharged by the epoxy-resin process. When the turbidity and suspended solid (SS) concentration in raw wastewater were 74 NTU and 4.1 mg/L, respectively, their values decreased the lowest in a coagulant dosage of 135.0 - 270.0 mg Al3+/L. The epoxy resin was re-dispersed in the upper part of wastewater treated above 405.0 mg Al3+/L. The removal efficiencies of turbidity and SS via dosing with aluminum sulfate and PAC were evaluated at initial turbidity and SS of 74 - 630 NTU and 4.1 - 38.5 mg/L, respectively. They increased most in the range from 135.0 - 270.0 mg Al3+/L. The solid-liquid separation condition was quantitatively compared to the correlation of SS removal efficiency between the coagulant dosage and SS concentration based on the concentration of aluminum ions. The empirical formula, R = beaD, shows the relationship between SS removal efficiency (R) and coagulant dosage (D) at 38.5 mg/L; it produced high correlation coefficients (r2) of 0.9871 for aluminum sulfate and 0.9751 for PAC.

Trajectory Simulation of ASR Particles in Induction Electrostatic Separation (유도형 정전선별에서 ASR 입자의 궤적모사)

  • Kim, Beom-uk;Park, Chul-hyun
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.96-105
    • /
    • 2019
  • Automobile shredder residue (ASR) is the final waste produced when end-of-life vehicles (ELVs) are shredded. ASR can be separated using mineral-processing operations such as comminution, air classification, magnetic separation, and/or electrostatic separation. In this work, trajectory analyses of conductors (copper) and non-conductors (glass) in the ASR have been carried out using induction electrostatic separator for predicting or improving the ASR-separation efficiency. From results of trajectory analysis for conductors, the trajectories of copper wire by observation versus simulation for coarse particles of 0.5 and 0.25 mm showed consistent congruity. The observed 0.06 mm fine-particles trajectory was deflected toward the (-) attractive electrode owing to the charge-density effects due to the particle characteristics and relative humidity. In the case of non-conductors, the actual trajectory of dielectric glass deflected toward the (-) electrode, showing characteristics similar to those of conductive particles. The analyses of stereoscopic microscope and SEM & EDS found heterologous materials (fine ferrous particles and conductive organics) on the glass surface. This demonstrates the glass decreasing separation efficiency for non-ferrous metals during electrostatic separation for the recycling of ASR. Future work will require a pretreatment process for eliminating impurities from the glass and advanced trajectory-simulation processes.

Separation and Purification of Bio Gas by Hollow Fiber Gas Separation Membrane Module (중공사형 기체분리막 모듈을 이용한 바이오가스의 분리 및 정제)

  • Koh, Hyung-Chul;Ha, Seong-Yong;Woo, Seung-Moon;Nam, Sang-Yong;Lee, Byung-Seong;Lee, Chung-Seop;Choi, Whee-Moon
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.177-192
    • /
    • 2011
  • Hollow fiber membrane using CTA polymers were prepared by the phase separation method for the separation and purification of biogas and the hollow fiber gas separation membrane modules with the effective surface area of 0.17 $m^2$ were prepared. The pure gas permeation properties of membrane modules for methane, oxygen and carbon dioxide were measured. The permeance of $CO_2$ and $CH_4$were 0.46 GPU and 18.52 GPU, respectively, therefore, the high $CO_2$/$CH_4$ selectivity of 40.4 was obtained. The separation and purification test for 4 different simulated mixed gases were carried out after the pure gas test and the gas concentration and flux of the permeate at the various stage-cut were measured from the 1 stage, 2 stage, and 3 stage cascade of membrane modules. In the 1 stage test, the concentration of $CH_4$ increased as the increase of the stage-cut, while the $CH_4$ recovery efficiency ratio decreased. In the 2 stage test, the $CH_4$ recovery efficiency ratio increased compared to the 1 stage. The 3 stage test was employed to reduce the loss of $CH_4$ in biogas and the result showed less than 5% of $CH_4$ recovery loss.

Removal of PVC from Mixed Plastic Waste by Combination of Air Classification and Centrifugal Process (풍력(風力) 및 습식비중(濕式比重) 선별(選別)에 의한 혼합(混合)폐플라스틱 종말품(終末品)으로부터 PVC 제거(除去)에 관한 연구(硏究))

  • Choi, Woo-Zin;Yoo, Jae-Myung
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.71-76
    • /
    • 2007
  • The mixed plastic waste generated from households after hand-picking and/or mechanical sorting processes amounts to 1,750,000 ton in 2006, and most of these waste are finally end up with landfill and/or incineration due to the lacks of separation technologies and economical reasons. The mixed plastic wastes can not be used as raw materials for chemical and/or thermal recycling processes because of their high content of PVC(upto 4.0 wt.%). In the present research, gravity separation system has been developed to remove PVC from the mixed plastic waste and to recover the PO-type plastics. This system mainly consists of air classification, magnetic separation, one-step crushing, feeding system at fixed rate and wet-type gravity separation system. The gravity system based on centrifugal separation has been developed at capacity of 0.5 ton/h and it consists of mixing, precleaning, separation, dewatering, recovery system and wastewater treatment system, etc. The main objective of this process is to achieve high separation efficiency of polyolefins with less than 0.3 wt.% PVC content and less than 10% moisture content in the final products. In addition, a crushing unit of with 8 rotor system is also developed to improve the crushing efficiency of soft-type plastics. The system with a capacity of 1.0 ton/h is developed and operational results are presented.

Evaluation of Flotation Efficiency and Particle Separation Characteristics of Carbon Dioxide Bubbles using Collision Efficiency Model (단일포집자충돌(SCC) 모델을 이용한 이산화탄소기포의 입자분리특성과 부상효율 평가)

  • Lee, Jun-Young;Kim, Seong-Jin;Yoo, Young-Hoon;Chung, Paul-Gene;Kwon, Young-Ho;Park, Yang-Kyun;Kwak, Dong-Heui
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.129-136
    • /
    • 2012
  • In this century, scientists realized that carbon dioxide gas in the atmosphere cause a greenhouse effect which affects the planet's temperature. Therefore lots of attempts have carried out to decrease the discharge of carbon dioxide gas in the field. The dissolved carbon dioxide flotation (DCF) process was developed as an alternative of DAF process to decrease the discharge and reuse of carbon dioxide as well as to save energy consumption. To investigate the particle separation characteristics and the flotation efficiency of carbon dioxide, SCC model was employed in the DCF process which has been applied extensively for the evaluation and simulation in the DAF process. The simulation results by the SCC model revealed the predicted curve of flotation efficiency became decreased gradually over the optimal pressure range of saturator about 1.6 atm in accordance with the experiment results of the DCF pilot plant and the size distribution and the bubble volume concentration of $CO_{2}$ bubbles depending on the operation pressure of saturator. The findings through the simulation results led to the conclusion that there was no significant difference between $CO_{2}$ bubbles and air bubbles, affecting on the practical flotation efficiency, in terms of the initial collision and attachment efficiency.

A Study on the Architectural Planning of Spatial Composition and Circulation in Private Regional Infectious Disease Hospital (민간 권역 감염병 전문병원의 공간구성 및 동선에 관한 건축계획 연구)

  • Choi, Kwangseok;Jeong, Dawoon;Kwon, Soon Jung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.4
    • /
    • pp.81-91
    • /
    • 2019
  • Purpose: Since infectious disease hospitals are premised on emergency operations, the operational efficiency of secured personnel, equipment, facilities, etc. is relatively low. In order to increase such normal operational efficiency, it is necessary to flexibly operate facilities and operations during normal and emergency times. The purpose of this study is to suggest the architectural planning method focusing on the space composition and circulation of the regional infectious disease hospital which can increase the operational efficiency in the private hospitals. Methods: Through literature review, functional requirements of infectious disease hospitals were identified, and related personnels inter-views and field surveys were conducted to understand the spatial composition and circulation requirements of infectious disease hospitals. Results: Through the complete separation between the negative pressure zone and the general zone, even when the negative pressure zone is completely closed, the general zone should be operated separately to achieve operational efficiency. In addition, the separation of the negative pressure zone and the general zone should simultaneously consider the optimal space configuration and movement for each function while the zone settings match in the floor plan of each department and the overall cross-sectional configuration of the hospital. Implications: Infectious disease hospitals intended to be installed in private hospitals should not apply excessive space just for safety reasons and should plan to ensure their operational efficiency.

Solid-liquid Separation Characteristics of Membrane Filter Press according to Coagulant Properties of Anaerobic Digestion Waste Water (혐기소화폐액의 응집제 특성에 따른 멤브레인 필터프레스의 고액분리 특성)

  • Han, Seong Kuk;Jung, Hee Suk;Song, Hyoung Woon;Kim, Ho;Ahn, Dae Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.23-32
    • /
    • 2014
  • Recently, it is increase in the processing of organic waste using anaerobic digestion. Therefore, the studies on the processing method for increasing the anaerobic digestion waste water. But it is very difficult to solid-liquid separation, because the characteristics of anaerobic digestion waste water. So this study evaluate solid-liquid separation efficiency of anaerobic digestion sludge using CST(Capillary Suction Time), TTF(Time to Filter). To address this problem, a membrane filter press of the lab scale was produced and the anaerobic digestion wastewater was applied to it. Polymer coagulants were found to be most suitable 7192PLUS and 1T60, It is necessary to minimum injection concentration is 7192PLUS (200 mg/L), 1T60 (100 mg/L). To evaluate dehydration efficiency, it was measured the moisture content of the dehydrated cake and suspended solids of decanted water. As a result, showed that a high removal efficiency of 97.4% when the solid-liquid separation using the membrane filter press. And the moisture content of the dehydrated cake was less than 65%.

Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems (해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성)

  • Kim Bu-Gi;Han Won-Hui;Cho Dae-Hwan;Choi Min-Seon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.2 s.23
    • /
    • pp.109-115
    • /
    • 2005
  • Hydrocyclone has been widely used for the solid-liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range particle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in the efficiency of cooling system In this paper, we have suggested some methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the separating performance of the Hydrocyclone were investigated The results from this study are summarized as follows: 1) In proportion to the decrease of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in machines, and eventually prevent unexpected accidents in engine systems.

  • PDF