• Title/Summary/Keyword: separation

Search Result 11,393, Processing Time 0.041 seconds

A Study on the Separation and Recovery of Magnesium from Waste Bittern (폐해수로부터 마그네슘의 분리.회수에 관한 연구)

  • Ju, Chang-Sik;Lee, Gyeong-Ok;Jeong, Seong-Uk;Park, Heung-Jae;Na, Seok-Eun;Jeong, Gap-Seon
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.381-386
    • /
    • 2001
  • The characteristics of precipitation separation and solvent extraction separation of magnesium from the waste bittern were studied experimentally In the result of precipitation separation, the size of magnesium hydroxide precipitated was not affected on pH, but decreased with increasing the precipitation temperature. The purity of magnesium oxide precipitated was increased with pH beyond pH 11. From the solvent extraction separation, the equilibrium extraction ratio of magnesium was increased with pH and temperature of extraction phase, the concentration of stripping phase, and with decreasing pH of stripping phase. The extractant of Aliquat 336 and Acid 810 mixture was more effective than that of DCH18C6 and $D_2EHPA$ mixture in the extraction separation of magnesium.

  • PDF

Separation Characteristic of Shatter Resistant Sesame After Threshing

  • Noh, Hyun Kwon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.299-303
    • /
    • 2014
  • Purpose: This study set out to develop a machine for separating shatter-resistant sesame after threshing. Methods: Three grades of sieve and different blower speeds were tested for a separation system that had been designed specifically for shatter-resistant sesame. Performance tests were run to evaluate the sieve and blower systems in terms of the sesame separation and loss ratios. Results: Tests of the first separation stage using the sieve system revealed the optimum sieve perforation size to be 5 mm. Tests of the second separation stage using the blower system identified the optimum blower speed as being 220 rpm. The optimum separation and loss ratios, of 96.5% and 3.5%, respectively, were obtained at a blower speed of 220 rpm. Conclusions: These results will be useful for the design, construction, and operation of threshing harvesters. For shatter-resistant sesame, an optimum blower speed of 220 rpm was identified.

Music/Voice Separation Based on Kernel Back-Fitting Using Weighted β-Order MMSE Estimation

  • Kim, Hyoung-Gook;Kim, Jin Young
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.510-517
    • /
    • 2016
  • Recent developments in the field of separation of mixed signals into music/voice components have attracted the attention of many researchers. Recently, iterative kernel back-fitting, also known as kernel additive modeling, was proposed to achieve good results for music/voice separation. To obtain minimum mean square error (MMSE) estimates of short-time Fourier transforms of sources, generalized spatial Wiener filtering (GW) is typically used. In this paper, we propose an advanced music/voice separation method that utilizes a generalized weighted ${\beta}$-order MMSE estimation (WbE) based on iterative kernel back-fitting (KBF). In the proposed method, WbE is used for the step of mixed music signal separation, while KBF permits kernel spectrogram model fitting at each iteration. Experimental results show that the proposed method achieves better separation performance than GW and existing Bayesian estimators.

Maternal Separation Anxiety on Quality of Day Care and Mother's Self-Esteem (탁아의 질과 어머니 자아존중감에 따른 어머니 격리불안)

  • 송진숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.309-319
    • /
    • 1997
  • The purpose of this study was to examine the maternal separation anxiety depending on the quality of day care and mother's self-esteem. subjects consisted of 187 mothers who had children from 60 t 36 months of age. the instruments used were the questionnaires which consisted of the Maternal separation anxiety scale(Cho and park, 1992), Self-Esteem Inventory(Coopersmith, 1967), and the checklist which consisted of the early childhood environment Rating scale(Harms & Clifford, 1980) and the Family Day Care Rating scale(Harms & Clifford, 1989). The datas were analyzed by the statistical method based o frequency, percentile, t-test, and one-way ANOVA. The main results were as follows : First, there was a significant difference in maternal separation anxiety by mothers' age and not by their educational levels. Second, there were no significant differences in maternal separation anxiety by children's age, sex, and girth order. Third, there was no significant difference in maternal separation anxiety by quality of day 2 care, size of group, and adult-child ratio. Forth, there was a significant differences in maternal separation anxiety by mother's self-esteem.

  • PDF

A Study on the Separation of Mixed Waste Plastics by Trioboelectrification (마찰대전을 이용한 혼합폐플라스틱 분리에 관한 연구)

  • Lee, Jong-Ho;Shin, Jin-Hyuk;Kim, Doo-Hyun;Kim, Jang-Woo;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.538-543
    • /
    • 2000
  • The purpose of this study is to develope electrostatic separation system for recycling of mixed waste plastics. The electrostatic separation system is designed and investigated the separation efficiency for separating of mixed waste plastics. Electrostatic separation system consisted of a tribocharger, separator (two electrode), collector (5 tray) and controller (positive/negative high voltage power supply). The tribocharger is a fluidized bed using tribo-electrification mechanism between particles and particles. In experimental results, the tribocharger of the fluidized bed was more effective separation efficiency. It showed the purity of $85{\sim}99\;%$ and the recovery of $80{\sim}98\;%$ from the powder of mixed plastics such as LDPE, HDPE, PP, PS, PET and PVC. Especially, In the separation experiment of Polyvinylchloride(PVC) which generates hazardous hydrogen chloride gas in case of the combustion. its purity was over 99 % and recovery was over 95 %.

  • PDF

Recovery of Diatom Skeleton from Low Grade Diatomaceous Earth by Shape Separation Method Using Fluid Field

  • Lee, Minyong;Yoon, Ki-Byung;Shigehisa Endoh
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.349-352
    • /
    • 2001
  • Shape separation method - a separation process which utilizes the fact that particles of different shape behave differently in force fields- is regarded as an useful measure for recycling, mineral processing, upgrading powdered material and so on. In this study, a trial was given to shape separation method using fluid field to recover pure diatom skeleton - which is thought to have many uses in itself and potential for various applications -from low grade diatomaceous earth of southeastern part of the Korean Peninsula. The striking difference of shape between diatom skeleton and other minerals like clay and quartz made it natural to choose shape separation method. Considering the size of particles to be separated, among many possible methods of shape separation, hydrodynamic field using hydrocyclone was adopted. And it resulted in recovery of pure diatom skeleton with high purity

  • PDF

Chiral Separation of Tryptophan Enantiomers by Liquid Chromatography with BSA-Silica Stationary Phase

  • Kim Kwonil;Lee Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.5 no.1
    • /
    • pp.17-22
    • /
    • 2000
  • The separation of tryptophan enantiomers was carried out with medium-pressure liquid chromatography using BSA (bovine serum albumin)-bonded silica as a chiral stationary phase. The influence of various experimental factors such as pH and ionic strength of mobile phase, separation temperature, and the presence of organic additives on the resolution was studied. In order to expand this system to preparative scale, the loadability of sample and the stability of stationary phase for repeated use were also examined. The separation of tryptophan enantiomers was successful with this system. The data indicated that a higher separation factor (a) was obtained at a higher pH and lower temperature and ionic strength in mobile phase. Addition of organic additives (acetonitrile and 2-propanol) in mobile phase contributed to reduce the retention time of L-tryptophan. About $30\%$ of the separation factor was reduced after 80 days of repeated use.

  • PDF

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.

Simulated Moving Bed [SMB] (모사 이동층 크로마토그래피)

  • Lee Chong-Ho;Koo Yoon-Mo
    • KSBB Journal
    • /
    • v.20 no.3
    • /
    • pp.192-196
    • /
    • 2005
  • Chromatography has been a method of choice in the separation of complex biological mixtures for the analytical purpose in particular for the last half of century. In current years, chromatographic method extends its use to the preparative separation where the productivity per resin amount and solvent use become a matter of concern. Recently, simulated moving bed (SMB) method which claims high separation efficiency of the ideal counter-current moving bed chromatography has become a workhorse of preparative separation. SMB technology was developed in the early 1960s for large-scale hydrocarbon separation by UOP and approximately 120 Sorbex units have been licensed to date. Recently, SMB separation technology has been successfully extended from hydrocarbons and sugars to fine chemicals, particularly biochemicals, from laboratory to pilot to production plant. In this paper, the current status of SMB and its modifications were reviewed.

Attachment with Caregivers and Adjustment of Korean-Chinese Children Separated from Their Parents (부모와 별거하는 중국 조선족 아동의 양육자에 대한 애착과 적응문제)

  • Cho, Bokhee;Lee, Joo-Yeon
    • Korean Journal of Child Studies
    • /
    • v.27 no.4
    • /
    • pp.247-263
    • /
    • 2006
  • Recruited from Korean-Chinese elementary schools in Shenyang and Harbin, China, 100 children living apart from their parents and experiencing non-maternal care provided information about the separation (reason and duration of parent-child separation, present location of parents, etc.), their adjustment to separation, and their perception of attachment with their caregivers. Results showed that although the separated children adjusted positively to parent-child separation in general, over 55% of them reported loneliness. Attachment with caregiver was the most significant influential variable on children's behavior problems. Duration of separation from father was related to children's hostility/aggression and hyperactivity/attention deficit problem, while duration of separation from mother influenced children's anxiety.

  • PDF