The Accuracy Improvement of FBG Temperature Sensor by using Wavelet Transform (웨이블릿 변환을 이용한 광섬유 격자 온도센서의 정밀도 개선)

  • Cho, Yo-Han;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.73-78
    • /
    • 2011
  • We developed a noise reduction algorithm for the measurement accuracy improvement of a fiber-optic distributed temperaure sensor system. The denoising technique is based on the wavelet transform. The proposed algorithm was applied to a FBG sensor output with the Gaussian line-fitting algorithm to minimize the output noise which originated from the intensity noise of the laser light source and the instability of signal porcessing. We confirmed the feasibility of the denoising algorithm by comparing the measurement results with those obtained with the Gaussian line-fitting algorithm only.

Flicker Prevention and Noise Reduction Using Edge-Spike Modulation in Visible Light Communication

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.143-149
    • /
    • 2018
  • In this paper, we introduce an edge-spike modulation method for visible light communication (VLC). This method is effective in preventing LED flicker and 120 Hz noise interference in base-band VLC. In the VLC transmitter, edge-spikes are generated by passing the digital data through a simple RC-high pass filter (HPF). The LED modulation of the edge-spikes does not change the average power of the LED light; thus it prevents LED flicker. In the VLC receiver, the 120 Hz noise from other lighting lamps is easily eliminated by RC-HPF, while the edge-spike signal is detected normally. In our experiment, the message of an air-quality sensor was successfully transmitted using edge-spike modulation. This structure is useful in constructing, e.g., wireless gas monitoring sensor systems to warn and prevent harmful gas leakage accidents in buildings using LED light.

Active Vibration Control of Flexible Plate using Piezo Ceramic (피에조 세라믹을 이용한 유연한 평판의 능동진동제어)

  • 박수홍;김홍섭;홍진석;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.434-439
    • /
    • 1997
  • This paper presents the active control of a flexible plate vibration. The plate was excited by white noise point force and the control was performed by one or two piezo ceramic actuator bonded to the surface of the plate. An adaptive controller based on filtered-x or multiple filtered-x LMS algorithm was used and the controller was defined by minimizing the square of the response of error sensor. In the experiment, PZT sensor was used as an error sensor while white noise was applied as a disturbance. In the case of multiple channel control, more than 22 dB of vibration reduction was achieved. Results indicate that the vibration of a flexible plate could be controlled effectively when the piezo ceramic actuator was used with multiple filtered-x LMS algorithm.

  • PDF

Performance Evaluation of Decision Fusion Rules of Wireless Sensor Networks in Generalized Gaussian Noise (Generalized Gaussian Noise에서의 무선센서 네트워크의 Decision Fusion Rule의 성능 분석에 관한 연구)

  • Park, Jin-Tae;Koo, In-Soo;Kim, Ki-Seon
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.97-98
    • /
    • 2006
  • Fusion of decisions from multiple distributed sensor nodes is studied in this work. Based on the canonical parallel fusion model, we derive the optimal likelihood ratio based fusion rule with the assumptions of the generalized Gaussian noise model and the arbitrary fading channel. This optimal fusion rule, however, requires the complete knowledge of the channels and the detection performance of local sensor nodes. To mitigate these requirements and to provide near optimum performance, we derive suboptimum fusion rules by using high and low signal-to-noise ratio (SNR) approximations to the optimal fusion rule. Performance evaluation is conducted through simulations.

  • PDF

A Study on Double Sampling Design of CMOS ROIC for Uncooled Bolometer Infrared Sensor using Reference Signal Compensation Circuit (기준신호 보상회로를 이용한 더블 샘플링 방식의 비냉각형 볼로미터 검출회로 설계에 관한 연구)

  • Bae, Young-Seok;Jung, Eun-Sik;Oh, Ju-Hyun;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.2
    • /
    • pp.89-92
    • /
    • 2010
  • A bolometer sensor used in an infrared thermal imaging system has many advantages on the process because it does not need a separate cooling system and its manufacturing is easy. However the sensitivity of the bolometer is low and the fixed pattern noise(FPN) is large, because the bolometer sensor is made by micro electro mechanical systems (MEMS). These problems can be fixed-by using the high performance readout integrated circuit(ROIC) with noise reduction techniques. In this paper, we propose differential delta sampling circuit to remove the mismatch noise of ROIC itself, the FPN of the bolometer. And for reduction of FPN noise, the reference signal compensation circuit which compensate the reference signal by using on-resistance of MOS transistor was proposed.

DWT-PCA Combination for Noise Detection in Wireless Sensor Networks (무선 센서 네트워크에서 노이즈 감지를 위한 DWT-PCA 조합)

  • Dang, Thien-Binh;Le, Duc-Tai;Kim, Moonseong;Choo, Hyunseung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2020.11a
    • /
    • pp.144-146
    • /
    • 2020
  • Discrete Wavelet Transform (DWT) is an effective technique that is commonly used for detecting noise in collected data of an individual sensor. In addition, the detection accuracy can be significant improved by exploiting the correlation in the data of neighboring sensors of Wireless Sensor Networks (WSNs). Principal component analysis is the powerful technique to analyze the correlation in the multivariate data. In this paper, we propose a DWT-PCA combination scheme for noise detection (DWT-PCA-ND). Experimental results on a real dataset show a remarkably higher performance of DWT-PCA-ND comparing to conventional PCA scheme in detection of noise that is a popular anomaly in collected data of WSN.

A Study on Optimal Sensor Placement Using Sensitivity Analysis (민감도 해석을 이용한 센서의 최적 위치 선정에 관한 연구)

  • Son, In-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.241-247
    • /
    • 2011
  • Although intensive development continues on innovative sensor systems, there is still considerable uncertainty in deciding on the number of sensors required and their locations in order to obtain adequate information on structural behavior. This paper is concerned with the sensor locations on a beam-structure for prognostic structural health monitoring. The purpose of this study is to investigate how to determine optimal sensor placement(OSP) from the sensitivity information of a known failure mode. The sensitivity of the forced vibration response of a beam to the variation of stiffness due to a crack is calculated analytically and used to determine the optimal sensor locations for the specified failure mode. The results of this method compared with the results of different OSP methods. The results have shown that the proposed method on optimal sensor placement is very effective in structural health monitoring.

Collocation of Sensor and Actuator for Active Control of Sound and Vibration (능동음향진동제어를 위한 센서와 액추에이터의 동위치화 연구)

  • 이영섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.778-783
    • /
    • 2003
  • The problem considered in this paper is about the collocation of sensor and actuator for the active control of sound and vibration. It is well-known that a point collocated sensor-actuator pair offers an unconditional stability with very high performance when it is used with a direct velocity feedback (DVFB) control, because the pair has strictly positive real (SPR) property. In order to utilize this SPR characteristics, a matched piezoelectric sensor and actuator pair is considered, but this pair suffers from the in-plane motion coupling problem with the out-of$.$plane motion due to the piezo sensor and actuator interaction. This coupling phnomenon limits the stability and performance of the matched pair with DVFB control. As a new alternative, a point sensor and piezoelectric actuator pair is also considered, which provides SPR property in all frequency range except at the first resonance in very low frequency. This non-SPR resonance could be minimized by applying a phase lag compensator.

  • PDF

Development of an Elastic Wave Sensor Including Rotary-encoding Capability (회전속도 측정 기능을 포함한 비접촉 탄성파 센서의 개발)

  • Lee, Ho-Cheol;Kim, Myong-Ho;Park, Jung-Yang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.143-146
    • /
    • 2006
  • In this paper, a hybrid sensor is proposed that has two capabilities: The first is to sense longitudinal of flexural elastic waves selectively which are transmitted along the targe shaft, the second to measure the rotating speed of the shaft. All measurement are made in a noncontact manner since this sensor uses magnetostriction as its measuring principles. Furthermore, the switching between these two sensing capabilities are accomplished by a very simple mechanical operation. To verify the capabilities of the Proposed sensor, an Prototype sensor are fabricated and the experiments are made. The result shows this sensor can embody two sensing capabilities in one sensor configuration.

  • PDF

Comparison test for PD measuring about UHF-sensor and HFCT-sensor in cable joint-box of MV grade (MV급 케이블 중간접속부의 PD 측정을 위한 UHF-센서와 HFCT-센서의 비교시험)

  • Shin, Dong-Hoon;Lee, Yong-Sung;Kim, Jung-Yoon;Yang, Jong-Seok;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1511-1512
    • /
    • 2006
  • In this paper, we measured PD signals from artificial surface defects and corona discharges under laboratory circumstances like the fields using both HFCT-sensor and UHF-sensor for MV grade XLPE cable with AMP, spectrum analyzer and oscilloscope. Also, detected signals were analyzed via PRPDA system in this paper. As a result, in this case of HFCT-sensor, the amount of background noise are larger than as compared to UHF-sensor. There is needed some hardware or software or software algorithm removing background noise effectively for diagnosis the underground power transmission cable in the case of HFCT-sensor.

  • PDF