DOI QR코드

DOI QR Code

A Study on Double Sampling Design of CMOS ROIC for Uncooled Bolometer Infrared Sensor using Reference Signal Compensation Circuit

기준신호 보상회로를 이용한 더블 샘플링 방식의 비냉각형 볼로미터 검출회로 설계에 관한 연구

  • Published : 2010.02.01

Abstract

A bolometer sensor used in an infrared thermal imaging system has many advantages on the process because it does not need a separate cooling system and its manufacturing is easy. However the sensitivity of the bolometer is low and the fixed pattern noise(FPN) is large, because the bolometer sensor is made by micro electro mechanical systems (MEMS). These problems can be fixed-by using the high performance readout integrated circuit(ROIC) with noise reduction techniques. In this paper, we propose differential delta sampling circuit to remove the mismatch noise of ROIC itself, the FPN of the bolometer. And for reduction of FPN noise, the reference signal compensation circuit which compensate the reference signal by using on-resistance of MOS transistor was proposed.

Keywords

References

  1. H. H. Shin, S. J. Hwang, E. S. Jung, S. W. Yu, and M. Y. Sung, “A readout IC design for the FPN reduction of the bolometer in an IR image sensor", Trans. Electr. Electron. Mater., Vol. 8, No. 5, p. 196, 2007. https://doi.org/10.4313/TEEM.2007.8.5.196
  2. S. G. Kang, D. H. Woo, and H. C. Lee, “Multiple integration method for high signalto-noise ratio readout integrated circuit", IEEE Transactions on Circuits and Systems, Vol. 52, No. 9, p. 553, 2005. https://doi.org/10.1109/TCSII.2005.848984