• Title/Summary/Keyword: sensor array optimization

Search Result 22, Processing Time 0.029 seconds

Sensor array optimization techniques for exhaled breath analysis to discriminate diabetics using an electronic nose

  • Jeon, Jin-Young;Choi, Jang-Sik;Yu, Joon-Boo;Lee, Hae-Ryong;Jang, Byoung Kuk;Byun, Hyung-Gi
    • ETRI Journal
    • /
    • v.40 no.6
    • /
    • pp.802-812
    • /
    • 2018
  • Disease discrimination using an electronic nose is achieved by measuring the presence of a specific gas contained in the exhaled breath of patients. Many studies have reported the presence of acetone in the breath of diabetic patients. These studies suggest that acetone can be used as a biomarker of diabetes, enabling diagnoses to be made by measuring acetone levels in exhaled breath. In this study, we perform a chemical sensor array optimization to improve the performance of an electronic nose system using Wilks' lambda, sensor selection based on a principal component (B4), and a stepwise elimination (SE) technique to detect the presence of acetone gas in human breath. By applying five different temperatures to four sensors fabricated from different synthetic materials, a total of 20 sensing combinations are created, and three sensing combinations are selected for the sensor array using optimization techniques. The measurements and analyses of the exhaled breath using the electronic nose system together with the optimized sensor array show that diabetic patients and control groups can be easily differentiated. The results are confirmed using principal component analysis (PCA).

Optimal Design and Analysis of a Medical Imaging Ultrasonic Array Sensor (의료 영상진단용 초음파 어레이 센서의 최적설계 및 특성해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.6
    • /
    • pp.263-270
    • /
    • 2008
  • The performance of an ultrasonic array sensor is determined by the properties of constituent materials and the effects of many structural parameters. In this study, with the finite element method, variation of the performances of an ultrasonic array sensor was analyzed in relation to its structural variables. Based on the analysis result, the structure of the ultrasonic array sensor was optimized to provide the highest sensitivity while satisfying such requirements as fractional bandwidth, center frequency and -20 dB pulse length. The optimization was carried out with the SQP-PD method for a target function composed of the ultrasonic array sensor performance. The optimized ultrasonic array sensor satisfied all the required specifications to be applicable to medical imaging diagnosis. The design technology in this paper can be utilized for other ultrasonic array sensors of a similar structure.

A Step-wise Elimination Method Based on Euclidean Distance for Performance Optimization Regarding to Chemical Sensor Array (유클리디언 거리 기반의 단계적 소거 방법을 통한 화학센서 어레이 성능 최적화)

  • Lim, Hea-Jin;Choi, Jang-Sik;Jeon, Jin-Young;Byu, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.258-263
    • /
    • 2015
  • In order to prevent drink-driving by detecting concentration of alcohol from driver's exhale breath, twenty chemical sensors fabricated. The one of purposes for sensor array which consists of those sensors is to discriminate between target gas(alcohol) and interference gases($CH_3CH_2OH$, CO, NOx, Toluene, and Xylene). Wilks's lambda was presented to achieve above purpose and optimal sensors were selected using the method. In this paper, step-wise sensor elimination based on Euclidean distance was investigated for selecting optimal sensors and compared with a result of Wilks's lambda method. The selectivity and sensitivity of sensor array were used for comparing performance of sensor array as a result of two methods. The data acquired from selected sensor were analyzed by pattern analysis methods, principal component analysis and Sammon's mapping to analyze cluster tendency in the low space (2D). The sensor array by stepwise sensor elimination method had a better sensitivity and selectivity compared to a result of Wilks's lambda method.

Optimization of sensor location for source localization : Minimum-Norm Least-Square Method (신호원 국소화를 위한 위치의 최적화 : MNLS)

  • 김유정;한주만;이인범;박광석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.124-126
    • /
    • 2000
  • The Minimum-Norm Least-Square(MNLS) approach based on lead field theory is an useful method to find an unique inverse solution for the measured magnetic field. The lead field depends on head geometry and location of sources and sensors. So, optimization of sensor array location is important issue for MNLS estimation. In this paper, we present an investigation for the optimization of sensor array location in computer simulation.

  • PDF

Optimal design of a sparse planar array sensor for underwater vehicles (수중 운동체용 희소 평면배열 센서의 최적 설계)

  • Afzal, Muhammad Shakeel;Roh, Yongrae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.1
    • /
    • pp.53-59
    • /
    • 2018
  • In this study, a new design method is developed to optimize the structure of an underwater sparse array sensor. The purpose of this research is to design the structure of a sparse array that has the performance equivalent to a fully sampled array. The directional factor of a sparse planar array is derived as a function of the structural parameters of the array. With the derived equation, the structure of the sparse array sensor is designed to have the performance equivalent to that of the fully array sensor through structural optimization of the number and location of transmitting and receiving elements in the array. The designed sparse array sensor shows beam patterns very close to those of the fully array sensor in terms of PSLL (Peak Side Lobe Level) and MLBW (Main Lobe Beam Width), which confirms the effectiveness of the present optimal design method. Further, the validity of the analytic beam patterns is verified by comparing them with those from the FEA (Finite Element Analysis) of the optimized sparse array structure.

Chemical Sensors Array Optimization Based on Wilks Lamda Technique (Wilks Lamda 방법을 이용한 화학센서 어레이 최적화)

  • Jeon, Jin-Young;Shin, Jeong-Suk;Yu, Joon-Boo;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.299-304
    • /
    • 2014
  • Optimizing the performance of a composite sensor array is necessary when the number of sensors to choose from is large. In this paper, we present a chemical sensors array optimization method using Wilks Lamda algorithm applicable a device to detect low concentration of alcohol from driver's exhale breath for interlocking engine ignition preventing drink-driving. More than 20 chemical sensors fabricated different synthetic stuffs and heater temperatures by collaborators were nominated, 5 sensors were selected for optimal sensors array using the method, and alcohol samples were well discriminated from the interference gases inside the vehicle. It has been confirmed by Principal Component Analysis (PCA).

Investigation of Chemical Sensor Array Optimization Methods for DADSS

  • Choi, Jang-Sik;Jeon, Jin-Young;Byun, Hyung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Nowadays, most major automobile manufacturers are very interested, and actively involved, in developing driver alcohol detection system for safety (DADSS) that serves to prevent driving under the influence. DADSS measures the blood alcohol concentration (BAC) from the driver's breath and limits the ignition of the engine of the vehicle if the BAC exceeds the reference value. In this study, to optimize the sensor array of the DADSS, we selected sensors by using three different methods, configured the sensor arrays, and then compared their performance. The Wilks' lambda, stepwise elimination and filter method (using a principal component) were used as the sensor selection methods [2,3]. We compared the performance of the arrays, by using the selectivity and sensitivity as criteria, and Sammon mapping for the analysis of the cluster type of each gas. The sensor array configured by using the stepwise elimination method exhibited the highest sensitivity and selectivity and yielded the best visual result after Sammon mapping.

A Weighted Least Square Method for Optimization of Thinned Sensor Arrays (희소어레이의 최적화를 위한 계수 최소 자승 방법)

  • 장병건
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.4
    • /
    • pp.78-83
    • /
    • 1999
  • This paper concerns a least square method for pattern optimization of a thinned sensor array in which the squared error between a desired pattern and a synthesized one is minimized. A weighting function is applied in the function with respect to the array visual range for a symmetric and asymmetric configuration for sensor spacing. An exponential weighting function is proposed to control the sidelobes efficiently around the mainbeam and to generate a uniform sidelobe. The resulting pattern may be employed to eliminate incoming interferences distributed uniformly around the array visual range.

  • PDF

A Sensing System of the Halbach Array Permanent Magnet Spherical Motor Based on 3-D Hall Sensor

  • Li, Hongfeng;Liu, Wenjun;Li, Bin
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.352-361
    • /
    • 2018
  • This paper proposes a sensing system of the Halbach array permanent magnet spherical motor(PMSM). The rotor position can be obtained by solving three rotation angles, which revolves around 3 reference axes of the stator. With the development of 3-D hall sensor, the position identification problem of the Halbach array PMSM based on rotor magnetic field is studied in this paper. A nonlinear and serious coupling relationship between the rotation angles and the measured magnetic flux density is established on the basis of the rotation transformation theory and the magnetic field model. In order to get rid of the influence on position detection caused by the harmonics of rotor magnetic field and the stator coil magnetic field, a sensor location combination scheme is proposed. In order to solve the nonlinear equation fast and accurately, a new position solution algorithm which combines the merits of gradient projection and particle swarm optimization(PSO) is presented. Then the rotation angles are obtained and the rotor position is identified. The validity of the sensing system is verified through the simulation.

SnO2 Hollow Hemisphere Array for Methane Gas Sensing

  • Hieu, Nguyen Minh;Vuong, Nguyen Minh;Kim, Dojin;Choi, Byung Il;Kim, Myungbae
    • Korean Journal of Materials Research
    • /
    • v.24 no.9
    • /
    • pp.451-457
    • /
    • 2014
  • We developed a high-performance methane gas sensor based on a $SnO_2$ hollow hemisphere array structure of nano-thickness. The sensor structures were fabricated by sputter deposition of Sn metal over an array of polystyrene spheres distributed on a planar substrate, followed by an oxidation process to oxidize the Sn to $SnO_2$ while removing the polystyrene template cores. The surface morphology and structural properties were examined by scanning electron microscopy. An optimization of the structure for methane sensing was also carried out. The effects of oxidation temperature, film thickness, gold doping, and morphology were examined. An impressive response of ~220% was observed for a 200 ppm concentration of $CH_4$ gas at an operating temperature of $400^{\circ}C$ for a sample fabricated by 30 sec sputtering of Sn, and oxidation at $800^{\circ}C$ for 2 hr in air. This high response was enabled by the open structure of the hemisphere array thin films.