• Title/Summary/Keyword: self-tuning regulator

Search Result 19, Processing Time 0.024 seconds

A Study on the Improvement of Air-Fuel Ratio Control Performance in Sl Engine Using STR (STR을 이용한 가솔린 엔진의 공연비 제어 성능 향상에 관한 연구)

  • 신규철;박승범;윤팔주;정남훈;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.57-64
    • /
    • 2001
  • This study presents an self tuning regulator(STR) to improve the air-fuel ratio control of performance of gasoline engine. The STR is designed based on the nonlinear dynamic engine model, and the performance of the STR is evaluated through the simulation and experiments. The STR shows better performance than a conventional PI controller in terms of the response time and disturbance rejection. Since the STR has less calculation load than the complex nonlinear controller, this algorithm can be easily applied to on-board engine controller.

  • PDF

Computer Aided Design of Multivariable Control Systems by Pole-Assignment Self-Tuning Regulators (극배치 자기-동조 안정기에 의한 다변수 제어계의 설계)

  • Shim, J.C.;Chun, S.Y.;Yim, W.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.76-78
    • /
    • 1987
  • This paper describes the theory and application of a multi-input/multi-output self-tuning regulator where the control objective is the assignment of the closed-loop pole set to prespecified locations. The algorithm described In this paper has a 'self-tuning' property. This self-tuners are more robust than the tuners that are based on optimal control synthesis method. This paper demonstrate usefulness of the algorithms by means of some simulation studies.

  • PDF

Robust Self-Tuning Regulator without Persistent Excitation (지속여기 조건이 없는 강인한 자조 안정기)

  • 김영철;이철희;양흥석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1207-1218
    • /
    • 1990
  • The lack of persistent excitation (PE) can be the reason of freezing in the recursive least square estimators and the covariance windup in the exponential weighted least square estimators. We present a theoretical analysis of these phenomena and a simple method to check the exciting condition in real time. Using these results and under some conditions such as slowly time varying Plant and a tracking problem for set point, a robust self-tuning regulators without PE is proposed. In this algorithm, when PE is not satisfied, only plant gain is estimated, and then the system parameters are corrected by it. It is shown that the gain adaptive scheme makes the robustness to be improved against modeling error, off-set, and correlated noise etc, by the results of analysis and simulations.

A study on the static excitation system using Self-Tuning Adaptive Control Algorithm (자기동조 제어알고리즘을 이용한 정지형 여자제어 시스템에 관한 연구)

  • Yoon, G.G.;Lim, I.H.;Kim, C.K.;Kim, K.C.;Rhew, H.W.;Kim, H.P.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.660-662
    • /
    • 1997
  • A new improved excitation control system for power plant synchronous generators has been developed by KEPRI (Korea Electric Power Research Institute). The reliability of the excitation system is increased by designing a dual channel automatic voltage regulator(AVR). Also the performance of the excitation system is improved by Self-Tuning adaptive Controller. A software package is developed for the excitation control system, and a field test is conducted to verify the system performance.

  • PDF

Control of DC Servo Motor using PID Controller Self-Tuning (PID제어기의 자기동조를 이용한 직류 서보전동기의 위치제어)

  • Kim, Gwon-Sub;Lee, Oh-Keol;Kim, Sang-Hyo;Ko, Tai-Eun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1113-1115
    • /
    • 1996
  • The servo system requires faster and more accurate dynamic responses. A new technique for the position control of DC servo motors is presented in this paper. The proposed technique employs a Self Tuning Regulator Proportional Integral Derivative(STR PID) position control systems in order to improve the dynamic performance of a DC servo motor. Recursive -least -squares (RLS) method is used in order to estimate the STR PID coefficients, $K_P$, $K_I$, and $K_D$. In order to consider dynamics such as voltage, angular velocity, and rotor angle, the above method was applied position control system.

  • PDF

Adaptive Control of Cell Recycled Continuous Bioreactor for Ethanol Production (에탄올 생산을 위한 세포재순환 연속 생물반응기의 적응제어)

  • 이재우;유영제
    • KSBB Journal
    • /
    • v.6 no.3
    • /
    • pp.263-270
    • /
    • 1991
  • The optimal cell concentration and dilution rate for maximum ethanol productivity were obtained using dynamic simulation in cell recycled continuous bioreactor. The good control performance was observed using rule-based STR (self-tuning regulator) compared to conventional STR. Rule-base contained the scheme to implement the STR in an efficient on-off way and the scheme for the controlled variable to reach the optimal value in a short time. Since a mathematical model was used to analyze and estimate the changes of the state variables and the parameters, it was possible to understand the physical meaning of the system.

  • PDF

An Effective Adaptive Autopilot for Ships

  • Le, Minh-Duc;Nguyen, Si-Hiep;Nguyen, Lan-Anh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.720-723
    • /
    • 2005
  • Ship motion is a complex controlled process with several hydrodynamic parameters that vary in wide ranges with respect to ship load condition, speed and surrounding conditions (such as wind, current, tide, etc.). Therefore, to effectively control ships in a designed track is always an important task for ship masters. This paper presents an effective adaptive autopilot ships that ensure the optimal accuracy, economy and stability characteristics. The PID control methodology is modified and parameters of a PID controller is designed to satisfy conditions for an optimal objective function that comprised by heading error, resistance and drift during changing course, and loss of surge velocity or fuel consumption. Designing of the controller for course changing process is based on the Model Reference Adaptive System (MRAS) control theory, while as designing of the automatic course keeping process is based on the Self Tuning Regulator (STR) control theory. Simulation (using MATLAB software) in various disturbance conditions shows that in comparison with conventional PID autopilots, the designed autopilot has several notable advantages: higher course turning speed, lower swing of ship bow even in strong waves and winds, high accuracy of course keeping, shorter time of rudder actions smaller times of changing rudder direction.

  • PDF

Application of Adaptive Control Theory to Nuclear Reactor Power Control (적응제어 기법을 이용한 원자로 출력제어)

  • Ha, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.336-343
    • /
    • 1995
  • The Self Tuning Regulator(STR) method which is an approach of adaptive control theory, is ap-plied to design the fully automatic power controller of the nonlinear reactor model. The adaptive control represent a proper approach to design the suboptimal controller for nonlinear, time-varying stochastic systems. The control system is based on a third­order linear model with unknown, time-varying parameters. The updating of the parameter estimates is achieved by the recursive extended least square method with a variable forgetting factor. Based on the estimated parameters, the output (average coolant temperature) is predicted one-step ahead. And then, a weighted one-step ahead controller is designed so that the difference between the output and the desired output is minimized and the variation of the control rod position is small. Also, an integral action is added in order to remove the steady­state error. A nonlinear M plant model was used to simulate the proposed controller of reactor power which covers a wide operating range. From the simulation result, the performances of this controller for ramp input (increase or decrease) are proved to be successful. However, for step input this controller leaves something to be desired.

  • PDF

An Evaluation of Multiple-input Dual-output Run-to-Run Control Scheme for Semiconductor Manufacturing

  • Fan, Shu-Kai-S.;Lin, Yen
    • Industrial Engineering and Management Systems
    • /
    • v.4 no.1
    • /
    • pp.54-67
    • /
    • 2005
  • This paper provides an evaluation of an optimization-based, multiple-input double-output (MIDO) run-to-run (R2R) control scheme for general semiconductor manufacturing processes. The controller in this research, termed adaptive dual response optimizing controller (ADROC), can serve as a process optimizer as well as a recipe regulator between consecutive runs of wafer fabrication. In evaluation, it is assumed that the equipment model could be appropriately described by a pair of second-order polynomial functions in terms of a set of controllable variables. Of practical relevance is to consider a drifting effect in the equipment model since in common semiconductor practice the process tends to drift due to machine aging and tool wearing. We select a typical application of R2R control to chemical mechanical planarization (CMP) in semiconductor manufacturing in this evaluation, and there are five different CMP process scenarios demonstrated, including mean shift, variance increase, and IMA disturbances. For the controller, ADROC, an on-line estimation technique is implemented in a self-tuning (ST) control manner for the adaptation purpose. Subsequently, an ad hoc global optimization algorithm based on the dual response approach, arising from the response surface methodology (RSM) literature, is used to seek the optimum recipe within the acceptability region for the execution of next run. The main components of ADROC are described and its control performance is assessed. It reveals from the evaluation that ADROC can provide excellent control actions for the MIDO R2R situations even though the process exhibits complicated, nonlinear interaction effects between control variables, and the drifting disturbances.