• Title/Summary/Keyword: self-calibration

Search Result 186, Processing Time 0.028 seconds

Self-calibration of a Multi-camera System using Factorization Techniques for Realistic Contents Generation (실감 콘텐츠 생성을 위한 분해법 기반 다수 카메라 시스템 자동 보정 알고리즘)

  • Kim, Ki-Young;Woo, Woon-Tack
    • Journal of Broadcast Engineering
    • /
    • v.11 no.4 s.33
    • /
    • pp.495-506
    • /
    • 2006
  • In this paper, we propose a self-calibration of a multi-camera system using factorization techniques for realistic contents generation. The traditional self-calibration algorithms for multi-camera systems have been focused on stereo(-rig) camera systems or multiple camera systems with a fixed configuration. Thus, it is required to exploit them in 3D reconstruction with a mobile multi-camera system and another general applications. For those reasons, we suggest the robust algorithm for general structured multi-camera systems including the algorithm for a plane-structured multi-camera system. In our paper, we explain the theoretical background and practical usages based on a projective factorization and the proposed affine factorization. We show experimental results with simulated data and real images as well. The proposed algorithm can be used for a 3D reconstruction and a mobile Augmented Reality.

Design of a Current Steering 10-bit CMOS D/A Converter Based on a Self-Calibration Bias Technique (자가보정 바이어스 기법을 이용한 Current Steering 10-bit CMOS D/A 변환기 설계)

  • Lim, ChaeYeol;Lee, JangWoo;Song, MinKyu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.91-97
    • /
    • 2013
  • In this paper, a current steering 10-bit CMOS D/A converter to drive a NTSC/PAL analog TV is proposed. The proposed D/A converter has a 50MS/s operating speed with a 6+4 segmented type. Further, in order to minimize the device mismatch, a self-calibration bias technique with a fully integrated termination resistance is discussed. The chip has been fabricated with a 3.3V 0.11um 1-poly 6-metal CMOS technology. The effective chip area is $0.35mm^2$ and power consumption is about 88mW. The experimental result of SFDR is 63.1dB, when the input frequency is 1MHz at the 50MHz of sampling frequency.

CMOS Programmable Interface Circuit for Capacitive MEMS Gyroscope (MEMS 용량형 각속도 센서용 CMOS 프로그래머블 인터페이스 회로)

  • Ko, Hyoung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.13-21
    • /
    • 2011
  • In this paper, the CMOS programmable interface circuit for MEMS gyroscope is presented, and evaluated with the MEMS sensing element. The circuit includes the front-end charge amplifier with 10 bit programmable capacitor arrays, 9 bit DAC for accurate offset calibration, and 10 bit PGA for accurate gain calibration. The self oscillation loop with automatic gain control operates properly. The offset error and gain error after calibration are measured to be 0.36 %FSO and 0.19 %FSO, respectively. The noise equivalent resolution and bias instability are measured to be 0.016 deg/sec and 0.012 deg/sec, respectively. The calibration capability of this circuit can reduce the variations of the output offset and gain, and this can enhance the manufacturability and can improve the yield.

Accuracy Analysis of 3D Position of Close-range Photogrammetry Using Direct Linear Transformation and Self-calibration Bundle Adjustment with Additional Parameters (DLT와 부가변수에 의한 광속조정법을 활용한 근접사진측량의 3차원 위치정확도 분석)

  • Kim, Hyuk Gil;Hwang, Jin Sang;Yun, Hong Sic
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.27-38
    • /
    • 2015
  • In this study, the 3D position coordinates were calculated for the targets using DLT and self-calibration bundle adjustment with additional parameters in close-range photogrammetry. And then, the accuracy of the results were analysed. For this purpose, the results of camera calibration and orientation parameters were calculated for each images by performing reference surveying using total station though the composition of experimental conditions attached numerous targets. To analyze the accuracy, 3D position coordinates were calculated for targets that has been identically selected and compared with the reference coordinates obtained from a total station. For the image coordinate measurement of the stereo images, we performed the ellipse fitting procedure for measuring the center point of the circular target. And then, the results were utilized for the image coordinate for targets. As a results from experiments, position coordinates calculated by the stereo images-based photogrammetry have resulted out the deviation of less than an average 4mm within the maximum error range of less than about 1cm. From this result, it is expected that the stereo images-based photogrammetry would be used to field of various close-range photogrammetry required for precise accuracy.

Nano Force Metrology and Standards (나노 힘 측정 및 표준)

  • Kim M.S.;Park Y.K.;Choi J.H.;Kim J.H.;Kang D.I.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.59-62
    • /
    • 2005
  • Small force measurements ranging from 1 pN to $100{\mu}N$, we call it Nano Force, become the questions of common interests of biomechanics, nanomechanics, material researches, and so on. However, unfortunately, quantitative and accurate force measurements have not been taken so far. This is because there ,are no traceable force standards and a calibration scheme. This paper introduces a quantitative force metrology, which provides traceable link to SI (International Systems of Units). We realize SI traceable force ranging from 1 nN to $100{\mu}N$ using an electrostatic balance and disseminate it through transfer standards, which are self-sensing cantilevers that have integrated piezoresistive strain gages. We have been built a prototype electrostatic balance and Nano Force Calibrator (NFC), which is an AFM cantilever calibration system. As a first experiment, we calibrated normal spring constants of commercial AFM cantilevers using NFC. Calibration results show that the spring constants of them are quite differ from each other and nominal values provided by a manufacturer (up to 240% deviation).

  • PDF

A Study on the Guided Wave Mode Conversion using Self-calibrating Technique (자가교정기법에 의한 유도초음파 모드전이에 관한 연구)

  • Park, Jung-Chul;Cho, Youn-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.3
    • /
    • pp.206-212
    • /
    • 2000
  • The guided wave mode conversion phenomena were investigated for the NDE of a plate-like structure with thickness variation. The ratios of reflection and transmission (R/T) were measured via the self-calibrating procedure which allows us to obtain experimental guided wave data in a more reliable way regardless of the coupling uncertainty between transducer & specimen. The results on R/T could be used to determine the thickness reduction of the structure. It was shown that not only the incident modes but also the converted ones need to be considered in the self-calibrating guided wave inspection to extract a reasonable correlation between experimental data & the thickness variation. Through this study, the potential of guided wave inspection as a quantitative NDE technique was explored based on the combined concept of self-calibration & multi-mode conversion in guided wave scattering problems.

  • PDF

Development of Localization Sensor System for Intelligent Robots (지능로봇용 위치인식 시스템 개발)

  • You, Ki-Sung;Choi, Chin-Tae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • A service robot can identify its own position relative to landmarks, the locations of which are known in advance. The main contribution of this research is that it gives various ways of making the self-localizing error smaller by referring to special landmarks which are developed as high gain reflection material and coded array associations. In this paper, the authors propose a set of indices to evaluate the accuracy of self-localizing methods using the selective reflection landmark and infrared projector, and the indices are derived from the sensitivity enhancement using 3D distortion calibration of camera. And then, the accurarcy of self-localizing a mobile robot with landmarks based on the indices is evaluated, and a rational way to minimize to reduce the computational cost of selecting the best self-localizing method. The simulation results show a high accuracy and a good performance.

The design of 4S-Van for implementation of ground-laser mapping system (지상 레이져 매핑시스템 구현을 위한 4S-Van 시스템 설계)

  • 김성백;이승용;김민수
    • Spatial Information Research
    • /
    • v.10 no.3
    • /
    • pp.407-419
    • /
    • 2002
  • In this study, the design of 4S-Van system is discussed fur the implementation of laser mapping system. Laser device is fast and accurate sensor that acquires 3D road and surface data. The orientation laser sensor is determined by loosely coupled (D)GPS/INS Integration. Considering current system architecture, (D)GPS/INS integration is performed far performance analysis of direct georeferencing and self-calibration is performed for interior and exterior orientation and displacement. We utilized 3 laser sensors for compensation and performance improvement. 3D surface data from laser scanner and texture image from CCD camera can be used to implement 3D visualization.

  • PDF

Fish-eye camera calibration and artificial landmarks detection for the self-charging of a mobile robot (이동로봇의 자동충전을 위한 어안렌즈 카메라의 보정 및 인공표지의 검출)

  • Kwon, Oh-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.278-285
    • /
    • 2005
  • This paper describes techniques of camera calibration and artificial landmarks detection for the automatic charging of a mobile robot, equipped with a fish-eye camera in the direction of its operation for movement or surveillance purposes. For its identification from the surrounding environments, three landmarks employed with infrared LEDs, were installed at the charging station. When the robot reaches a certain point, a signal is sent to the LEDs for activation, which allows the robot to easily detect the landmarks using its vision camera. To eliminate the effects of the outside light interference during the process, a difference image was generated by comparing the two images taken when the LEDs are on and off respectively. A fish-eye lens was used for the vision camera of the robot but the wide-angle lens resulted in a significant image distortion. The radial lens distortion was corrected after linear perspective projection transformation based on the pin-hole model. In the experiment, the designed system showed sensing accuracy of ${\pm}10$ mm in position and ${\pm}1^{\circ}$ in orientation at the distance of 550 mm.