• Title/Summary/Keyword: seismic-protection

Search Result 154, Processing Time 0.028 seconds

Seismic performance of hybrid isolation plate-shell integrated concrete LSS

  • Lei Qi;Xuansheng Cheng;Shanglong Zhang;Yuyue Bu;Bingbing Luo
    • Earthquakes and Structures
    • /
    • v.27 no.1
    • /
    • pp.57-67
    • /
    • 2024
  • To assess the seismic performance of Plate-Shell Integrated Concrete Liquid-Storage Structure (PSICLSS), a scaled test model was constructed. This model incorporated a hybrid isolation system, which combined shape memory alloy (SMA), lead-cored rubber isolation bearing (LRB) and sliding isolation bearing (SB). By conducting shaking table test, the dynamic responses of both non-isolated and hybrid-isolated PSICLSS were analyzed. The results show that the hybrid isolation system can effectively reduce the acceleration and displacement responses of the structure. However, it also results in an increase in local hydrodynamic pressure and liquid sloshing height. Under extreme earthquake action, the displacement of isolation layer is small. When vertical ground motion is taken into account, the shock absorption rate of horizontal acceleration decreases. The peak hydrodynamic pressure increases significantly, and the peak hydrodynamic pressure position also changes. The maximum displacement of isolation layer increases, the residual displacement decreases.

Uniform Hazard Spectra of 5 Major Cities in Korea (국내 5개 주요 도시에 대한 등재해도 스펙트럼)

  • Kim, Jun-Kyoung;Wee, Soung-Hoon;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.37 no.3
    • /
    • pp.162-172
    • /
    • 2016
  • Since the Northridge earthquake in 1994 and the Kobe earthquake in 1995 occurred, the concept of performance based design has been introduced for designing various kinds of important structures and buildings. Uniform hazard spectra (UHS), with annual exceedance probabilities, corresponding to the performance level of each structure, are required for performance-based design. The probabilistic seismic hazard analysis was performed using spectral ground motion prediction equations, which were developed from both Korean Peninsula and Central and Eastern US region, and several seismotectonic models suggested by 10 expert panel members in seismology and tectonics. The uniform hazard spectra for 5 highly populated cities in Korea, with recurrence period of 500, 1,000, and 2,500 years using the seismic hazard at the frequencies of 0.5, 1.0, 2.0, 5.0, 10.0 Hz and Peak ground acceleration (PGA) were analyzed using the probabilistic seismic hazard analysis. The sensitivity analysis suggests that spectral ground motion prediction equations impact much more on seismic hazard than what seismotectonic models do. The uniform hazard spectra commonly showed a maximum hazard at the frequency of 10 Hz and also showed the similar shape characteristics to the previous study and related technical guides to nuclear facilities.

A Study on the Disaster Prevention Technology of the Switchboard with Upper and Lower Bending Type Seismic Pads (상하굴절형 내진패드를 설치한 수배전반 방재기술에 관한 연구)

  • Lee, Taeshik;Seok, Gumcheul;Lee, Jaewon;Kim, Taejin;Kim, Jaekwon;Cho, Woncheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2017
  • The purpose of this study is to investigate the effect of vertical and horizontal refraction on the lower part of the power supply and control system of various facilities and machinery that use electricity, so that the power distribution system, which is an important electric facility installed in buildings and public facilities, Type earthquake resistant pads to protect the substructure and prevent short-circuiting on the upper part of the system. The GR-63-CORE (Scale 8.3 class) It is earthquake disaster prevention and disaster prevention technology that satisfies seismic performance. As a research result, it is possible to protect the electricity and communication infrastructure, which can contribute to shortening the time for recovering the electric facilities to the normal state in case of an earthquake, and preventing the fire caused by the destruction of the electricity supply facility in case of an earthquake. As a result, it is possible to minimize the spread of fire that occurs when a large-scale earthquake occurs and to minimize the damage of people and damage to property, and it can contribute to the securing of electric infrastructure that enables citizens to quickly recover to daily life even after suffering a major earthquake. In addition, the technology can be applied to ensure the seismic resistance of the equipment in the communication and computer room, and it can be applied to various fields where the facility function can be stopped due to the shaking of the earthquake base.

The Dynamic Basement Amplification Characteristics of a Dam Site using a Reference Site Method (기준관측소 방법을 이용한 댐체 기반암의 동적 지반증폭특성)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa
    • Journal of the Korean earth science society
    • /
    • v.38 no.2
    • /
    • pp.161-171
    • /
    • 2017
  • Observed ground motions are composed of three factors such as, seismic source, attenuation, and site amplification effect. Among them, the site amplification characteristics should be considered significantly when estimating seismic source and attenuation characteristics with more confidence. The site effect is also necessary when estimating not only seismic hazard in seismic design engineering but also rock mechanical properties. This study uses the method of H/V spectral ratio of observed ground motion between target site and reference site called a reference site method. In addition to using the vertical Fourier spectrum of the reference site, we try out the horizontal Fourier spectrum as a new method in this study. We analyze H/V spectral ratio of six ground motions respectively, observed at four sites close to Yedang Reservoir. We then compare site amplification effects at each site using 3 kinds of seismic energies including S waves, Coda waves energy, and background noise. The results suggest that each site showed similar site amplification patterns in S waves and Coda waves energy. However, the site amplification of background noise shows much different characteristics from those of S waves and Coda wave energy, which suggests that the background noises at each site have their own developing mechanism. Each station shows its own characteristics of specific resonance frequency and site amplification properties in low, high and specific resonance frequency ranges. Comparison of the method used in this study to the others that used different methods can provide us with more information about the dynamic amplification of a site characteristics and site classification.

A Study of the Improvement Plan and Real Condition Estimation of Fire Protection Safety Management for Power Plants in Korea (국내발전소 소방안전관리 운영실태조사 및 개선방안에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-wook
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.61-73
    • /
    • 2017
  • The Fukushima Nuclear Disaster in 2011 and California Power Failure in 2001 are examples of the importance of the power plant safety management that caused huge national loss with a power-related mass casualty incident. In a situation where humans cannot live without electricity, efforts to strengthen the systematic firefighting safety management in power plants that produce electricity with large amounts of hazardous materials as fuel, such as nuclear energy, coal and gas, are essential to protect life and prevent property loss and stable economic growth from fire explosion accident or radiation leak due to the negligence of safety management and natural disasters such as earthquakes, which has recently become an issue. This study examined the operating situation of firefighting safety management in power plants with firefighting officials employed by five power generation companies including Korea Southern Power Co., Ltd. and Korea Hydro & Nuclear Power Co. Ltd., which are in charge of the domestic power supply. As a result, for the systematic firefighting safety management of power plants, improvement plans were drawn, including the development of an effective business manual and a comprehensive management system, the substantiality of firefighting safety education, and the strengthening of seismic designs to prepare for earthquakes.

Seismic Response Control of a Cable-Stayed Bridge Using Passive, Active, Semiactive and Hybrid Systems (수동, 능동, 반능동 및 복합 시스템을 이용한 사장교의 지진응답 제어)

  • ;;Spencer, B. F.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.17-29
    • /
    • 2003
  • This paper preliminarily investigates the effectiveness of various control systems, such as passive, active, semiactive and hybrid control, for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. This benchm.0.00000ark problem considers the cable-stayed bridge that is scheduled for completion in Missouri, USA In 2003. Seismic considerations were strongly considered in the design of this bridge due to location of the bridge and its critical role as a principal crossing of the Mississippi River. Based on detailed drawings of this cable-stayed bridge, a three-dimensional linearized evaluation model has been developed to represent the complex behavior of the bridge. A set of eighteen evaluation criteria has been developed to evaluate the capability of each control system. In this study, four passive control systems, one active control system, two semiactive control systems and three hybrid control systems are considered. Numerical simulation results show that all the control systems are effective in reducing the responses of the benchmark cable-stayed bridge under the historical earthquakes. To get good performance, however, the passive control systems need quite large control forces compared to other control systems. The simulation results also demonstrate that the passive, semiactive and hybrid control systems are robust to the stiffness uncertainty of the structure. Therefore, the semiactive and hybrid control systems are more appropriate in real applications for full-scale civil infrastructures.

A Comparison Study of the Amplification Characteristics of the Seismic Station near Yedang Reservoir using Background Noise, S-wave and Coda wave Energy (배경잡음, S파 및 Coda파 에너지를 이용한 예당저수지 인근부지의 지반증폭 특성에 관한 비교 연구)

  • Wee, Soung-Hoon;Kim, Jun-Kyoung;Yoo, Seong-Hwa;Kyung, Jai-Bok
    • Journal of the Korean earth science society
    • /
    • v.36 no.7
    • /
    • pp.632-642
    • /
    • 2015
  • Seismograms are composed of 3 characteristics, that is, seismic source, attenuation, and site amplification. Among them, site amplification characteristics should be considered significantly to estimate seismic source and attenuation characteristics with more confidence. This purpose of this study is to estimate the site amplification characteristics at each site using horizontal to vertical (H/V) spectral ratio method. This method, originally proposed by Nakamura (1989), has been applied to study the surface waves in microtremor records. It has been recently extended to the shear wave energy of strong motion and applied to the study of site amplification. This study analyzed the H/V spectral ratio of 6 ground motions respectively using observed data from 4 sites nearby in Yedang Reservoir. And then, site amplification effects at each site, from 3 kinds of seismic energies, that is, S waves, Coda waves energy, and background noise were compared each other. The results suggested that 4 sites showed its own characteristics of site amplification property in specific resonance frequency ranges (YDS: ~11 Hz, YDU: ~4 Hz, YDD: ~7 Hz). Comparison of this study to other studies using different analysis method can give us much more information about dynamic amplification of domestic sites characteristics and site classification.

Hybrid Control of a Benchmark Cable-Stayed Bridge Considering Nonlinearity of a Lead Rubber Bearing (납고무받침의 비선형성을 고려한 벤치마크 사장교의 복합제어)

  • Park, Kyu-Sik;Jung, Hyun-Jo;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.4
    • /
    • pp.51-63
    • /
    • 2002
  • This paper presents a hybrid control strategy for seismic protection of a benchmark cable-stayed bridge, which is provided as a testbed structure for the development of strategies for the control of cable-stayed bridges. This benchmark problem considers the cable-stayed bridge that is scheduled for completion in Cape Girardeau, Missouri, USA in 2003. Seismic considerations were strongly considered in the design of this bridge due to the location of the bridge in the New Madrid seismic zone and its critical role as a principal crossing of the Mississippi river. Based on detailed drawings of this cable-stayed bridge, a three-dimensional linearlized evaluation model has been developed to represent the complex behavior of the bridge. A set of eighteen evaluation criteria has been developed to evaluate the capabilities of each control strategy. In this study, a hybrid control system is composed of a passive control system to reduce the earthquake-induced forces in the structure and an active control system to further reduce the bridge responses, especially deck displacements. Conventional base isolation devices such as lead rubber bearings are used for the passive control design and Bouc-Wen model is used to simulate the nonlinear behavior of these devices For the active control design, ideal hydraulic actuators are used and on $H_2$/LQG control algorithm is adopted. Numerical simulation results show that the performance of the proposed hybrid control strategy is quite effective compared to that of the passive control strategy and slightly better than that of the active control strategy. The hybrid control method is also more reliable than the fully active control method due to the passive control part. Therefore, the proposed hybrid control strategy can effectively be used to seismically excited cable-stayed bridges.

Behavior of Seepage and Seismic for the Deterioration Reservoir Using Numerical Analysis (수치해석에 의한 노후저수지의 침투 및 동적거동)

  • Park, Sung-Yong;Chang, Suk-Hyun;Lim, Hyun-Taek;Kim, Jung-Meyon;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.3
    • /
    • pp.81-90
    • /
    • 2016
  • It is significant to redevelop the deterioration reservoir through raising for countermeasure to climate change and Earthquake improvement of reservoir. This study aims to investigate the behavior of deterioration reservoir with poor-fabricated core subjected to raising water level and earthquake using numerical analysis. From the analysis results, water level raising and earthquakes induce crack and subsidences at the crown and the front side of deterioration reservoir. For the reinforcement of the deterioration reservoir is required appropriate measures method and raised method suitable, drainage and slope protection method judged to be necessary.

Implementation of Uniform Deformation Theory in semi-active control of structures using fuzzy controller

  • Mohammadi, Reza Karami;Haghighipour, Fariba
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.351-360
    • /
    • 2017
  • Protection of structures against natural hazards such as earthquakes has always been a major concern. Semi-active control combines the reliability of passive control and versatility and adaptability of active control. So it has recently become a preferred control method. This paper proposes an algorithm based on Uniform Deformation Theory to mitigate vulnerable buildings using magneto-rheological (MR) damper. Due to the successful performance of fuzzy logic in control of systems and its simplicity and intrinsically robustness, it is used here to regulate MR dampers. The particle swarm optimization (PSO) algorithm is also used as an adaptive method to develop a fuzzy control algorithm that is able to create uniform inter-story drifts. Results show that the proposed algorithm exhibited a desirable performance in reducing both linear and nonlinear seismic responses of structures. Performance of the presented method is indicated in compare with passive-on and passive-off control algorithms.