• 제목/요약/키워드: seismic structural protection

검색결과 75건 처리시간 0.025초

Dynamic analysis of a historical monument: retrofit using shape memory alloy wires

  • Hamdaoui, Karim;Benadla, Zahira
    • Smart Structures and Systems
    • /
    • 제13권3호
    • /
    • pp.375-388
    • /
    • 2014
  • The effectiveness of using the advanced seismic protection technology based on shape memory alloy (SMA) dampers to preserve a historical minaret is investigated. The proposed studied case, the minaret of Mansourah, is a seven century old minaret located in Tlemcen, Algeria. Its original height was of 47m, while nowadays, the monument is half destructed and its current height reaches the 40m. The proposed seismic retrofit is based on the technique that utilizes SMA wires as dampers for the upper flexible part of the minaret. The effectiveness of the proposed technique is numerically evaluated via non-linear finite element analysis using the structural software ANSYS. The effectiveness of the proposed device in mitigating the seismic hazard is demonstrated by the effective reduction in its dynamic response.

수직 행거 내진설계용 스티프너의 단조 압축 실험 (Monotonic Loading Tests on Seismic Stiffeners for Vertical Hangers)

  • 오창수;공하성
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.187-192
    • /
    • 2023
  • In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.

주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토 (Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building)

  • 박광섭;김윤태;김현수
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

Structural monitoring and identification of civil infrastructure in the United States

  • Nagarajaiah, Satish;Erazo, Kalil
    • Structural Monitoring and Maintenance
    • /
    • 제3권1호
    • /
    • pp.51-69
    • /
    • 2016
  • Monitoring the performance and estimating the remaining useful life of aging civil infrastructure in the United States has been identified as a major objective in the civil engineering community. Structural health monitoring has emerged as a central tool to fulfill this objective. This paper presents a review of the major structural monitoring programs that have been recently implemented in the United States, focusing on the integrity and performance assessment of large-scale structural systems. Applications where response data from a monitoring program have been used to detect and correct structural deficiencies are highlighted. These applications include (but are not limited to): i) Post-earthquake damage assessment of buildings and bridges; ii) Monitoring of cables vibration in cable-stayed bridges; iii) Evaluation of the effectiveness of technologies for retrofit and seismic protection, such as base isolation systems; and iv) Structural damage assessment of bridges after impact loads resulting from ship collisions. These and many other applications show that a structural health monitoring program is a powerful tool for structural damage and condition assessment, that can be used as part of a comprehensive decision-making process about possible actions that can be undertaken in a large-scale civil infrastructure system after potentially damaging events.

등방성 이력형 강재댐퍼를 이용한 RC 라멘조 아파트건물의 지진응답 개선 (Mitigating Seismic Response of RC Framed Apartment Building Using Isotropic Hysteretic Steel Dampers)

  • 천영수;방종대
    • 토지주택연구
    • /
    • 제5권2호
    • /
    • pp.107-114
    • /
    • 2014
  • 수동형 제진장치를 이용하는 제진구조는 수년간 개발이 지속되고 있으며, 1990년대 중반이후로 여러 나라들에서 실무적인 적용이 빠르게 증가되고 있다. 국내의 경우 이러한 제진장치 중 강재이력형 댐퍼가 비교적 저렴한 비용과 설치와 관리가 용이하다는 이유로 건물의 내진설계를 위하여 보편적으로 많이 적용되고 있다. 이 논문에서는 건물의 지진응답을 개선하기 위하여 적용된 소위 카고메댐퍼로 불리우는 등방성 강재이력형 댐퍼(Isotropic Hysteretic Metallic Damper, IHMD)의 유효성에 대한 해석적인 사례연구를 제시하고 있다. 연구대상 건물은 18층 규모의 철근콘크리트 라멘조 아파트건물로 해석결과를 통하여 IHMD의 실효성을 실증적으로 보여주고 있다. 해석결과는 IHMD가 건물의 지진응답을 줄일 수 있는 매우 효과적인 방법임을 검증하고 있다.

Seismic behavior of deep-sea pipeline after global buckling under active control

  • Jianshuo Wang;Tinghao Meng;Zechao Zhang;Zhihua Chen;Hongbo Liu
    • Earthquakes and Structures
    • /
    • 제26권4호
    • /
    • pp.261-267
    • /
    • 2024
  • With the increase in the exploitation depth of offshore oil and gas, it is possible to control the global buckling of deep-sea pipelines by the snake lay method. Previous studies mainly focused on the analysis of critical buckling force and critical temperature of pipelines under the snake-like laying method, and pipelines often suffer structural failure due to seismic disasters during operation. Therefore, seismic action is a necessary factor in the design and analysis of submarine pipelines. In this paper, the seismic action of steel pipes in the operation stage after global buckling has occurred under the active control method is analyzed. Firstly, we have established a simplified finite element model for the entire process cycle and found that this modeling method is accurate and efficient, solving the problem of difficult convergence of seismic wave and soil coupling in previous solid analysis, and improving the efficiency of calculations. Secondly, through parameter analysis, it was found that under seismic action, the pipe diameter mainly affects the stress amplitude of the pipeline. When the pipe wall thickness increases from 0.05 m to 0.09 m, the critical buckling force increases by 150%, and the maximum axial stress decreases by 56%. In the pipe soil interaction, the greater the soil viscosity, the greater the pipe soil interaction force, the greater the soil constraint on the pipeline, and the safer the pipeline. Finally, the pipeline failure determination formula was obtained through dimensionless analysis and verified, and it was found that the formula was accurate.

지진하중을 받는 사장교를 위한 LRB-기반 복합 기초격리 시스템 (LRB-based Hybrid Base Isolation Systems for Seismically Excited Cable-Stayed Bridges)

  • 정형조;박규식;이헌재;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.527-534
    • /
    • 2003
  • This paper presents the LRB-based hybrid base isolation systems employing additional active/semiactive control devices for seismic protection of cable-stayed bridges by examining the ASCE first generation benchmark problem for a cable-stayed bridge. In this study, ideal hydraulic actuators (HAs) and ideal magnetorheological dampers (MRDs) are considered as additional active and semiactive control devices, respectively. Numerical simulation results show that all the hybrid base isolation systems are effective in reducing the structural responses of the benchmark cable-stayed bridge under the historical earthquakes considered. The simulation results also demonstrate that the hybrid base isolation system employing semiactive MRBs is robust to the stiffness uncertainty of the structure, while the hybrid system with active HAs is not. Therefore, the LRB-based hybrid base isolation system employing MRDs could be more appropriate in real applications for full-scale civil infrastructures.

  • PDF

철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측 (Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures)

  • 정우영;주부석
    • 한국지진공학회논문집
    • /
    • 제15권3호
    • /
    • pp.37-43
    • /
    • 2011
  • 구조물 내 설치된 파이프시스템은 주로 내부구성원들의 인간생활에 근간이 되는 기반시설로서 현대 도시생활의 생명선과 같은 역할을 한다. 이들 구조물 내 파이프시스템이 만약 지진발생에 의하여 손상될 경우 1차적으로 구조물 내 기능성이 저하되고 구조물 내 많은 정신적, 물질적 피해가 발생할 수 있다. 실제 내진공학에서 지진발생에 따른 비구조재요소의 거동은 크게 중요하게 고려되지 않으나 인적 및 물적 피해와 매우 밀접하게 연관되는 가스 혹은 수계파이프시스템에 대한 비구조적 요소의 거동예측 및 성능평가 연구는 보다 효과적인 구조물 유지관리를 위하여 그 필요성이 크다고 판단된다. 본 연구는 현재 일반적으로 널리 시공되어져 있는 노후 철근콘크리트 빌딩구조물 내 설치된 가스 혹은 수계파이프시스템에 대하여 실제 지진발생이 예측되는 거동을 살펴보고 이들 거동에 따른 성능평가 및 현 설계기준에 대한 검토도 병행하여 수행하고자 한다. 이를 위하여 본 연구에서는 해석적으로 발생 가능한 총 10회의 지진파에 대하여 현재 실제 건물 내 기설치된 수계파이프시스템 모델링 및 해석을 통하여 그 결과를 검증, 평가하였으며 부가적으로 실제 발생 가능한 파괴유형 분석을 통하여 현 설치된 수계파이프시스템의 설계에 대한 적절한 내진보강방법에 대하여도 제안하고자 한다.

1980년대 학교교사에 대한 보, 기둥 및 접합부 사이의 파괴모드 분석 (Analysis of Failure Modes among Beams, Columns, and Joints for School Buildings Constructed in the 1980s)

  • 최명호;하세연;이창환
    • 한국공간구조학회논문집
    • /
    • 제21권3호
    • /
    • pp.51-60
    • /
    • 2021
  • As earthquakes continue to occur in Korea in recent years, seismic evaluation and retrofit of existing school buildings have been carried out. Many domestic school buildings were built using or referring to standard drawings. Therefore, if the overall structural characteristics of a school building can be known first based on standard drawings, it can be provided as valuable data for detailed seismic evaluation. For this reason, this study investigated the weak structural components and failure modes by comparing the strength of beams, columns, and joints constituting standard school buildings constructed in the 1980s. The evaluation was performed for different types of standard drawings and different material strengths. The results showed that the joint was mainly the weakest due to the eccentricity, and the failure modes were partially changed depending on the material strength.

Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion

  • Quaranta, Giuseppe;Mollaioli, Fabrizio;Monti, Giorgio
    • Earthquakes and Structures
    • /
    • 제10권1호
    • /
    • pp.239-260
    • /
    • 2016
  • Tuned mass dampers (TMDs) have been frequently proposed to mitigate the detrimental effects of dynamic loadings in structural systems. The effectiveness of this protection strategy has been demonstrated for wind-induced vibrations and, to some extent, for seismic loadings. Within this framework, recent numerical studies have shown that beneficial effects can be achieved by placing a linear TMD on the roof of linear elastic structural systems subjected to pulse-like ground motions. Motivated by these positive outcomes, closed-form design formulations have been also proposed to optimize the device's parameters. For structural systems that undergo a near-fault pulse-like ground motion, however, it is unlikely that their dynamic response be linear elastic. Hence, it is very important to understand whether such strategy is effective for inelastic structural systems. In order to provide new useful insights about this issue, the paper presents statistical results obtained from a numerical study conducted for three shear-type hysteretic (softening-type) systems having 4, 8 and 16 stories equipped with a linear elastic TMD. The effectiveness of two design procedures is discussed by examining the performances of the protected systems subjected to 124 natural pulse-like earthquakes.