• 제목/요약/키워드: seismic shaking

검색결과 427건 처리시간 0.032초

기와집 실물크기 모델의 지진 실험 (Seismic Test of a Full Scale Model of Wood House with Tiled Roof)

  • 류혁;김재관;전봉희;김병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.368-373
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a full scale model of wood house with tiled roof was performed. Full scale model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

초가집 1/2 축소 모델의 지진 실험 (Seismic Test of a 1/2 Scale Model of Wood House with Thatched Roof)

  • 류혁;김재관;허영철;전봉희
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.247-252
    • /
    • 2003
  • To improve the reliability of seismic hazard assessment of historic earthquake, shaking table test of a 1/2 scale model of wood house with thatched roof was peformed. Scaled model was constructed through rigorous verification process to have quantitative relationship between the intensity of earthquake and damage state. The completed model was mounted on a shaking table and subjected to the dynamic tests. Two kinds of tests were performed: exploratory test and fragility test. The exploratory test was done with low intensity shaking. In the fragility test, the behavior of the model was carefully monitored while increasing the shaking intensity. The construction details of the model are provided and test procedures are reported. Finally important test results are presented and their implications are discussed.

  • PDF

1/3축소 3층 삼환까뮤 P.C 모델의 진동대 실험 (Shaking Table Test of 1/3-Scale 3-Story Sam-Hwan Camus Precast Concrete Model)

  • 이한선
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.140-154
    • /
    • 1992
  • The objective of the research stated here was aimed at providing the information needed to establish the Korean Seismic Design Code Recommendations and Guides for precast concrete (P.C) large panel apartment buildings. This was accomplished by investigation and analysis of the response of P.C large panel structures subjected to shaking table excitation simulating earthquake ground motion. one of the test specimens used was 1/3-scaled 3-story box P.C model provided by Sam-Hwan Camus Corporation. The 4m $\times$4m shaking table was used to simulate the earthquake ground motion. the employed input accelerogram was the one recorded as Taft N21E component and the peak ground acceleration(PGA) was scaled depending on the desired level of seismic severity and the time according to dynamic similitude rule. Based on results obtained from shaking table test of this P.C model, the following conclusions were drawn . (1) As far as test specimen is concerned, the seismic safety factors turns out to be 7~8. (2)P.C model has damping ratio of about8% which is twice larger than in-situ R.C. structure. And (3)this model has global displacement ductility ratio of 2~3 through the energy dissipation by opening and sliding of joints.

  • PDF

Shaking table test and numerical analysis of a combined energy dissipation system with metallic yield dampers and oil dampers

  • Zhou, Qiang;Lu, Xilin
    • Structural Engineering and Mechanics
    • /
    • 제17권2호
    • /
    • pp.187-201
    • /
    • 2004
  • A shaking table test on a three-story one-bay steel frame model with metallic yield dampers and their parallel connection with oil dampers is carried out to study the dynamic characteristics and seismic performance of the energy dissipation system. It is found from the test that the combined energy dissipation system has favorable reducing vibration effects on structural displacement, and the structural peak acceleration can not evidently be reduced under small intensity seismic excitations, but in most cases the vibration reduction effect is very good under large intensity seismic excitations. Test results also show that stiffness of the energy dissipation devices should match their damping. Dynamic analysis method and mechanics models of these two dampers are proposed. In the analysis method, the force-displacement relationship of the metallic yield damper is represented by an elastic perfectly plastic model, and the behavior of the oil damper is simulated by a velocity and displacement relative model in which the contributions of the oil damper to the damping force and stiffness of the system are considered. Validity of the analytical model and the method is verified through comparison between the results of the shaking table test and numerical analysis.

진동대 실험을 통한 적층고무받침의 내진성능 평가 (Estimation of Aseismatic Performance of Laminated Rubber Bearing Through Shaking Table Tests)

  • 박성규
    • 한국철도학회논문집
    • /
    • 제13권4호
    • /
    • pp.440-446
    • /
    • 2010
  • 본 논문은 적층고무받침을 이용하여 지진으로부터 교량의 손상피해를 줄이기 위한 연구이다. 적층고무 받침은 지진 발생시 변위를 증가시키고, 주기를 길게하여 하중을 전환시킨다. 적층고무받침과 같은 면진장치에 몇 가지 지진파를 가진하여 진동대 실험을 하였다. 이 실험에서는 가속도계와 하중계, 변위계를 설치하여 상판의 가속도 및 전단력 등을 측정하였다. 더구나 적층고무받침을 설치한 경우와 지진격리장치를 설치하지 않은 경우로 구분하여 진동대 실험하여 그 성능을 비교 평가하였다. 실험결과 상판의 가속도 및 전단력은 적층고무받침을 사용할 경우 응답이 감소하였다.

L형 케이슨 안벽 구조물의 내진성 평가를 위한 진동대 시험 (Shaking Table Tests for Evaluation of Seismic Performance of L-type Caisson Quay Walls)

  • 한진태;황재익;이용재;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 춘계 학술발표회논문집
    • /
    • pp.148-156
    • /
    • 2003
  • Shaking table tests and pseudo-static analysis were performed, in this study, on newly-designed aseismatic L-type caisson quay walls, which were constructed by extending the bottom plate of gravity quay walls into the backfill soil. The L-type quay walls are expected to give economical benefits by reducing the cross-sectional area of the wall while maintaining its aseismatic efficiency as much as the classical caisson gravity quay wall. To confirm the effectiveness of the L-type structure, the geometry of L-type quay walls were varied for shaking table tests. And, to verify the influence of backfill soils on the seismic behavior of quay walls, additional shaking table tests were performed on the L-type quay wall after the backfill soils were replaced by gravels and light materials. As a result, it was found that L-type caisson quay walls are good earthquake resistant structures but increasing the length of bottom plate did not proportionally increase the effectiveness of the structure in its aseismatic performance. Replacing the backfill soils by the gravels and light materials, contrary to our expectation, was not an effective measure in improving the seismic performance of L-type caisson quay wall.

  • PDF

Centrifuge shaking table tests on a friction pendulum bearing isolated structure with a pile foundation in soft soil

  • Shu-Sheng, Qu;Yu, Chen;Yang, Lv
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.517-526
    • /
    • 2022
  • Previous studies have shown that pile-soil interactions have significant influences on the isolation efficiency of an isolated structure. However, most of the existing tests were carried out using a 1-g shaking table, which cannot reproduce the soil stresses resulting in distortion of the simulated pile-soil interactions. In this study, a centrifuge shaking table modelling of the seismic responses of a friction pendulum bearing isolated structure with a pile foundation under earthquakes were conducted. The pile foundation structure was designed and constructed with a scale factor of 1:100. Two layers of the foundation soil, i.e., the bottom layer was made of plaster and the upper layer was normal soil, were carefully prepared to meet the similitude requirement. Seismic responses, including strains, displacement, acceleration, and soil pressure were collected. The settlement of the soil, sliding of the isolator, dynamic amplification factor and bending moment of the piles were analysed to reveal the influence of the soil structure interaction on the seismic performance of the structure. It is found that the soil rotates significantly under earthquake motions and the peak rotation is about 0.021 degree under 24.0 g motions. The isolator cannot return to the initial position after the tests because of the unrecoverable deformation of the soil and the friction between the curved surface of the slider and the concave plate.

원전 전기캐비넷의 지진취약도 재평가를 위한 진동대 실험 (A Shaking Table Test for an Re-evaluation of Seismic Fragility of Electrical Cabinet in NPP)

  • 김민규;최인길
    • 한국전산구조공학회논문집
    • /
    • 제24권3호
    • /
    • pp.295-305
    • /
    • 2011
  • 본 연구에서는 원자력발전소의 주요 설비중의 하나인 전기설비를 대상으로 지진취약도 재평가를 위한 진동대 실험을 수행하였다. 원자력발전소 내에는 많은 전기설비들이 설치되어 있으며, 이러한 전기설비의 손상은 전기설비 자체의 손상에서 그치는 것이 아니고 발전소 전체의 안전성에 큰 영향을 미칠 수 있다. 따라서 원자력발전소의 확률론적 지진안전성 평가에서는 주요 전기설비에 대한 지진취약도 결과를 활용한 평가를 수행하고 있다. 본 연구에서는 기존의 확률론적 지진안전성 평가에서 사용하고 있는 전기설비의 지진취약도 값에 대한 재평가를 위하여 원자력발전소에서 사용하고 있는 주요 기기에 대한 진동대 실험을 수행하였다. 평가대상 전기설비로는 480V MCC를 선정하였으며, 진동대 실험을 위하여 NRC 설계지진, 등재해도 스펙트럼에 의한 인공지진 그리고 PAB165'에서의 층응답스펙트럼을 이용한 인공지진의 3가지 지진파를 이용하였다. 설계지진동 수준인 최대지반가속도 0.2g부터 단계적으로 입력수준을 증가시키면서 실험을 수행하였다. NUREG/CR-5203에서 제시하고 있는 방법에 의거하여 캐비넷에서의 증폭비를 비교하였으며, EPRI TR-103959의 방법으로 취약도 평가를 수행하여 기존의 확률론적 지진안전성 평가에서 사용하고 있는 지진취약도 결과와 비교하였다. 결론적으로 기존의 보고서에서 제시하고 있는 취약도 결과가 다소 보수적으로 평가하고 있음을 알 수 있었다.

진동대 실험을 통한 밸브실 시스템의 내진성능 평가 (Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests)

  • 정영수;이경석;유진석;정형채
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권1호
    • /
    • pp.46-52
    • /
    • 2024
  • 연약지반에서의 도로 침하 및 지진에 의한 누수 및 수도관의 파열에 따라 배관시스템용 신축이음장치의 구조적 안전성이 강조되고 있다. 일반적으로 배관 시스템의 다양한 손상을 방지하기 위해 신축이음에 금속 벨로우즈 사용하고 있다. 본 연구에서는 밸브실 시스템의 내진 성능을 평가하기 위해 진동대를 이용하여 내진시험을 수행하였다. 밸브실과 강관연결부의 구조적 안전성 평가를 위하여 신축이음(벨로우즈) 및 일반배관을 적용하였으며, 변형률 게이지를 부착하여 지진동에 의한 영향을 분석하였다. 진동대 실험결과, 일반배관이 적용된 경우보다 신축이음(벨로우즈)을 설치한 경우에 밸브실 구조체 및 유입·유출관의 변형율 1/100 및 1/20 수준으로 감소를 확인하였다.

진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구 (Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests)

  • 남민준;박승희;김동준;최준성
    • 한국지진공학회논문집
    • /
    • 제16권4호
    • /
    • pp.9-18
    • /
    • 2012
  • 본 연구에서는 진동대 실험을 통한 수계형 소화설비의 내진성능평가를 실시하였다. 실험에 사용된 수계형 소화설비 시설에는 일반 배관, 내진형 배관, 펌프 등 이다. 그리고 수계형 소화설비 시설의 동적거통특성을 파악하기 위하여 El-Centro 지진파 50%, 70%, 100%, 120% 수준의 가진을 가하였다. 그 결과, 내진형 설비보다 일반형 설비에서 변위 응답과 가속도 응답이 큰 것으로 보아 내진형 설비가 일반설비에 비해 내진성능이 우수하다는 것을 알 수 있었다. 또한, 가진 수준별 가속도 응답스펙트럼을 통하여 일반형 시설과 내진형 시설의 성능 평가뿐만 아니라 작은 규모의 지진에서도 일반형 설비의 파괴가 일어날 수 있다는 것을 알 수 있었다. 본 연구를 통해 수계 소화설비의 내진성능을 평가 할 수 있었고 수계 소화설비의 내진성능 기준을 검증할 수 있었다.