• 제목/요약/키워드: seismic performances

검색결과 195건 처리시간 0.025초

Seismic behavior factors of buckling-restrained braced frames

  • Kim, Jinkoo;Park, Junhee;Kim, Sang-Dae
    • Structural Engineering and Mechanics
    • /
    • 제33권3호
    • /
    • pp.261-284
    • /
    • 2009
  • The seismic behavior of a framed structure with chevron-type buckling restrained braces was investigated and their behavior factors, such as overstrength, ductility, and response modification factors, were evaluated. Two types of structures, building frame systems and dual systems, with 4, 8, 12, and 16 stories were designed per the IBC 2003, the AISC LRFD and the AISC Seismic Provisions. Nonlinear static pushover analyses using two different loading patterns and incremental dynamic analysis using 20 earthquake records were carried out to compute behavior factors. Time history analyses were also conducted with another 20 earthquakes to obtain dynamic responses. According to the analysis results, the response modification factors turned out to be larger than what is proposed in the provision in low-rise structures, and a little smaller than the code-values in the medium-rise structures. The dual systems, even though designed with smaller seismic load, showed superior static and dynamic performances.

Effect of semi-rigid connections in improvement of seismic performance of steel moment-resisting frames

  • Feizi, M. Gholipour;Mojtahedi, A.;Nourani, V.
    • Steel and Composite Structures
    • /
    • 제19권2호
    • /
    • pp.467-484
    • /
    • 2015
  • Seismic performances of dual steel moment-resisting frames with mixed use of rigid and semi-rigid connections were investigated to control of the base shear, story drifts and the ductility demand of the elements. To this end, nonlinear seismic responses of three groups of frames with three, eight and fifteen story were evaluated. These frames with rigid, semi-rigid and combined configuration of rigid and semi-rigid connections were analyzed under five earthquake records and their responses were compared in ultimate limit state of rigid frame. This study showed that in all frames, it could be found a state of semi-rigidity and connections configuration which behaved better than rigid frame, with consideration of the base shear and story drifts criterion. Finally, some criteria were suggested to locate the best place of the semi-rigid connections for improvement of the seismic performance of steel moment-resisting frames.

Nonlinear seismic performance of code designed perforated steel plate shear walls

  • Barua, Kallol;Bhowmick, Anjan K.
    • Steel and Composite Structures
    • /
    • 제31권1호
    • /
    • pp.85-98
    • /
    • 2019
  • Nonlinear seismic performances of code designed Perforated Steel Plate Shear Walls (P-SPSW) were studied. Three multi-storey (4-, 8-, and 12-storey) P-SPSWs were designed according to Canadian seismic provisions and their performance was evaluated using time history analysis for ground motions compatible with Vancouver response spectrum. The selected code designed P-SPSWs exhibited excellent seismic performance with high ductility and strength. The current code equation was found to provide a good estimation of the shear strength of the perforated infill plate, especially when the infill plate is yielded. The applicability of the strip model, originally proposed for solid infill plate, was also evaluated for P-SPSW and two different strip models were studied. It was observed that the strip model with strip widths equal to center to center diagonal distance between each perforation line could reasonably predict the inelastic behavior of unstiffened P-SPSWs. The strip model slightly underestimated the initial stiffness; however, the ultimate strength was predicted well. Furthermore, applicability of simple shear-flexure beam model for determination of fundamental periods of P-SPSWs was studied.

선형구조해석을 통한 노후된 학교시설 내진성능평가 (Seismic Performance Evaluation of An Old School Building Through Linear Analysis)

  • 이도형;김태완;김승래;추유림;김현식
    • 산업기술연구
    • /
    • 제38권1호
    • /
    • pp.21-27
    • /
    • 2018
  • In January 2018, the Ministry of Education published "Seismic design criteria for school buildings" and "Manual for seismic performance evaluation and retrofit of school buildings" to evaluate seismic performances through linear analysis. This paper evaluates the seismic performance of an old school building through the linear analysis. The target building was constructed in the late 1970s, and the seismic-force-resisting system was assumed to be a reinforced concrete moment frame with an un-reinforced masonry wall. As a result of the evaluation, the target building does not satisfy the 'life safety' level of 1.2 times the design spectrum. The average strength ratio of moment frames, an indicator of the level of seismic performance tends to be controlled by beams. However, through the Pohang earthquake, it was known that the short column effect caused by the partially infilled masonry wall caused shear failure of the columns in school buildings. Therefore, it is necessary to improve the linear analysis so that the column controls the average strength ratio of moment frames.

Comparative investigation of the costs and performances of torsional irregularity structures under seismic loading according to TEC

  • Gursoy, Senol
    • Computers and Concrete
    • /
    • 제14권4호
    • /
    • pp.405-417
    • /
    • 2014
  • The poor seismic performance of reinforced concrete buildings during the latest earthquakes has become a serious issue in the building industry in Turkey. This case, designing new buildings without structural irregularities against earthquake loads reveals to be quite significant. This study mainly is focused on the effects of different torsional irregularities on construction costs and earthquakes performance of reinforced concrete buildings. In that respect, structural torsional irregularities are investigated based on the Turkish Earthquake Code. The study consists of major eight main parametric models. In this models consist of totally 49 models together with the variations in the number of storey. With this purpose, the earthquake performances and construction costs (especially steel quantities) of reinforced concrete buildings which having different structural torsional irregularities were obtained with the help of Sta4-CAD program. Each model has been analyzed by both the methods of equivalent earthquake loading and dynamic analysis. The obtained results reveal that the model-1 which has lower torsional irregularity coefficient shows the best earthquake performance owing to its regular plan geometry. Also, economical comparisons on costs of the torsional irregularity are performed, and results-recommendations are given.

$\mu$-합성법을 이용한 사장교의 지진응답 제어 (Seismic Response Control of a Cable-Stayed Bridge using a $\mu$-Synthesis Method)

  • 박규식;정형조;윤우현;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.476-483
    • /
    • 2004
  • This paper presents a hybrid system combining lead rubber bearings and hydraulic actuators controlled by a μ-synthesis method for seismic response control of a cable-stayed bridge. A hybrid system could alleviate some of restrictions and limitations that exist when each system is acting alone because multiple control devices are operating. Therefore, the overall control performance of a hybrid system may be improved compared to each system, however the overall system robustness may be negatively impacted by active device in the hybrid system or active controller may cause instability due to small margins. Therefore, a f-synthesis method that guarantees the robust performance is considered to enhance the possibility of real applications of the control system. The control performances of the proposed control system are compared with those of passive, active, semiactive control systems and hybrid system controlled by LQG algorithm and an extensive robust analysis with respect to stiffness and mass matrices perturbation and time delay of actuator is performed. Numerical simulation results show that the control performance of the proposed control system is superior to that of the passive system and slightly better than that of the active and semiactive systems and two hybrid systems show similar control performances. Furthermore, the hybrid system controlled by a μ-synthesis method shows the good robustness without loss of control performances. Therefore, the proposed control system could effectively be used to seismically excited cable-stayed bridge which contains many uncertainties.

  • PDF

관통형 연결재로 연결된 PC 보-기둥 맞댐 접합의 내진성능에 관한 실험적 연구 (Seismic Performance of Precast Beam-Column Joints with Thru-Connectors)

  • 박순규;김민희
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.441-450
    • /
    • 2010
  • 건식공법이 가능하도록 기존의 접합 방식과 차별화 되는 PC 보-기둥 접합부를 개발하여 실용화하기 위한 기초 연구이다. 연속된 PC 기둥 양편에 위치한 보의 접합 단부를 고강도 관통형 연결재로 긴장하여 연결하는 'PC 보-기둥 맞댐 접합(BCJ_TB : precast beam column joints connected with thru-connects)'을 고안하고 실험적 연구를 수행하여 강도저하, 초기강성, 강성저하, 에너지소산능력 등의 내진성능을 분석하였다. 실험 결과에 기둥에서는 손상이 발생하지 않고 보 단부에서 압축파괴가 발생하는데, 이는 비부착 연결재의 초기긴장과 비부착 효과에 의하여 보 단부 콘크리트에 압축응력이 증가하기 때문인 것으로 분석되었다. 보 접합 단부에 CFRP로 구속 효과를 준 접합부의 성능이 상대적으로 우수하였고 네오프렌 패드로 보 기둥 접합면을 연결한 것이 다른 것에 비하여 초기강성을 제외하고는 우수한 내진성능을 보이는 것으로 분석되었다. 비부착 연결재를 사용한 접합부의 파괴모드를 개선하기 위하여 보 단부 콘크리트의 압축 성능을 향상시키고, 연결재의 변위를 적절히 조절할 수 있는 방법이 요구된다.

CFRP를 이용한 비내진 철근콘크리트 외부 보-기둥 접합부의 내진 보강 (Seismic Retrofit of RC Exterior Beam-Column Joints Strengthened with CFRP)

  • 김민;이기학;이재홍;우성우;이정원
    • 콘크리트학회논문집
    • /
    • 제18권6호
    • /
    • pp.729-736
    • /
    • 2006
  • 적절한 내진상세로 설계되지 않은 철근콘크리트 구조물은 보-기둥 접합부내에서 취약한 전단파괴에 노출되고 큰 변형이 일어나, 구조적인 붕괴가 일어날 수 있다. 본 연구는 CFRP로 보강한 철근콘크리트 외부 보-기둥 접합부를 반복 횡력을 적용하여 보강된 보-기둥 접합부의 내진성능을 알아보았다. 보-기둥 접합부의 구조적 성능을 향상시키기 위해 CFRP의 부착 위치나 두께를 달리하여 효과적인 보강방법을 관찰하고자 하였다. 비내진상세로 배근된 실험체 1개와 내진상세로 배근된 실험체 1개 그리고 비내진상세를 가진 실험체를 CFRP로 보강한 실험체 6개, 총 8개의 보-기둥 접합부 실험체에 반복횡력을 가하여 내진보강의 효과를 조사하였다. 반복 횡력을 적용하였다. 본 연구에서는 비내진상세를 가진 콘크리트 보-기둥 접합부에 대한 CFRP의 보강방법은 구조물의 강도와 연성을 증가시켜 구조물의 내진성능을 향상시키는데 효과적임을 보여 주었다.

내진성능 향상을 위한 고성능 철근콘크리트 말뚝 설계에 관한 연구 (Design of High Performance Reinforced Concrete Pile for Improvement of Seismic Performance)

  • 박찬식;조정래;김영진;진원종;윤혜진;최명규
    • 한국지진공학회논문집
    • /
    • 제23권3호
    • /
    • pp.183-190
    • /
    • 2019
  • Recent changes in the construction method of piles to minimize noise, along with the development of high-strength reinforcement, have provided an economical high performance RC pile development to compensate for the disadvantages of existing PHC piles. In this study, a methodology for the development of cross - section details of high performance RC piles of various performances is presented by freely applying high strength steel and concrete. This study suggested a technique for calculating bending moments for a given axial force corresponding to the allowable crack widths and this can be used for serviceablity check. In calculating the design shear force, the existing design equation applicable to the rectangular or the I section was modified to be applicable to the hollow circular section. In particular, in the limit state design method, the shear force is calculated in proportion to the axial force, and the procedure for calculating PV diagram is established. Last, the section details are determined through PM diagrams that they have the similar flexural and axial-flexural performances of the PHC pile A, B and C types with a diameter of 500 mm. To facilitate the application of the selected standard sections to the practical tasks, the design PM diagram and design shear forces are proposed in accordance with the strength design method and limit state design method.

중간모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections With Intermediate Moment Frame Details)

  • 김선훈;조종;오효근;최석동;여운용;이득행
    • 한국지진공학회논문집
    • /
    • 제27권3호
    • /
    • pp.129-137
    • /
    • 2023
  • This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.