DOI QR코드

DOI QR Code

선형구조해석을 통한 노후된 학교시설 내진성능평가

Seismic Performance Evaluation of An Old School Building Through Linear Analysis

  • LEE, Do Hyung (NARA Structural Engineers. Co., Ltd) ;
  • Kim, Taewan (Department of Architectural Engineering, Kangwon University) ;
  • Kim, Seung Re (Department of Architectural Engineering, Kangwon University) ;
  • Chu, Yurim (Department of Architectural Engineering, Kangwon University) ;
  • Kim, Hyun Sik (Department of Architectural Engineering, Kangwon University)
  • 투고 : 2018.09.27
  • 심사 : 2018.10.19
  • 발행 : 2018.10.31

초록

In January 2018, the Ministry of Education published "Seismic design criteria for school buildings" and "Manual for seismic performance evaluation and retrofit of school buildings" to evaluate seismic performances through linear analysis. This paper evaluates the seismic performance of an old school building through the linear analysis. The target building was constructed in the late 1970s, and the seismic-force-resisting system was assumed to be a reinforced concrete moment frame with an un-reinforced masonry wall. As a result of the evaluation, the target building does not satisfy the 'life safety' level of 1.2 times the design spectrum. The average strength ratio of moment frames, an indicator of the level of seismic performance tends to be controlled by beams. However, through the Pohang earthquake, it was known that the short column effect caused by the partially infilled masonry wall caused shear failure of the columns in school buildings. Therefore, it is necessary to improve the linear analysis so that the column controls the average strength ratio of moment frames.

키워드

참고문헌

  1. Pohang city hall, 2017, 11. 15 Eathquake damage investigation and damage control, Pohang City Disaster Safety Countermeasures Headquarters, Korea.
  2. Korean educational development institute, 2011, Guideline on Seismic Evaluation and Upgrading of School Buildings, Korea.
  3. Korea infrastructure safety corporation, 2013, Seismic Performance Evaluation for Existing Facilities(Buildings), Korea.
  4. Ministry of Education, 2018, Seismic design criteria for school buildings, Korea.
  5. Ministry of Education, 2018, Manual for seismic performance evaluation and retrofit of school buildings, Korea.
  6. AIK, 2016, Korean building code-structural, Korea.
  7. MIDAS IT, 2017, MIDAS GEN - User Manual. ver 860, MIDAS IT inc.