• 제목/요약/키워드: seismic gap

검색결과 114건 처리시간 0.021초

Establishing optimal gap size for precast beam bridges with a buffer-gap-elastomeric bearings system

  • Farag, Mousa M.N.;Mehanny, Sameh S.F.;Bakhoum, Mourad M.
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.195-219
    • /
    • 2015
  • A partial (hybrid) seismic isolation scheme for precast girder bridges in the form of a "buffer-gap-elastomeric bearings" system has been endorsed in the literature as an efficient seismic design system. However, no guides exist to detail an optimal gap size for different configurations. A numerical study is established herein for different scenarios according to Euro code seismic requirements in order to develop guidelines for the selection of optimal buffer-gap arrangements for various design cases. Various schemes are hence designed for ductile and limited ductility behavior of the bridge piers for different seismic demand levels. Seven real ground records are selected to perform incremental dynamic analysis of the bridges up to failure. Bridges with typical short and high piers are studied; and different values of initial gaps at piers are also investigated varying from a zero gap (i.e., fully locked) condition up to an initial gap at piers that is three quarters the gap left at abutments. Among the main conclusions is that the as-built initial gaps at piers (and especially large gap sizes that are ${\geq}1/2$ as-built gaps at abutments) do not practically reduce the seismic design demand and do not affect the reserve capacity of the bridge against failure for bridges featuring long piers, especially when these bridges are designed a priori for ductile behavior. To the contrary, the "buffer-gap-elastomeric bearings" system is more effective for the bridge schemes with short piers having a large difference between the stiffness of the bearings and that of their supporting (much stiffer) squat piers, particularly for designs with limited ductility. Such effectiveness is even amplified for the case of larger initial as-built gap sizes at piers.

An investigation into adequacy of separation gap to preclude earthquake-induced pounding

  • Yazan Jaradat;Pejman Sobhi and Harry Far
    • Structural Engineering and Mechanics
    • /
    • 제86권1호
    • /
    • pp.29-48
    • /
    • 2023
  • Pounding happens when contiguous structures with differing heights vibrate out of line caused by a seismic activity. The situation is aggravated due to the insufficient separation gap between the structures which can lead to the crashing of the buildings or total collapse of an edifice. Countries around the world have compiled building standards to address the pounding issue. One of the strategies recommended is the introduction of the separation gap between structures. AS1170.4-2007 is an Australian standard that requires 1% of the building height as a minimum separation gap between buildings to preclude pounding. This article presents experimental and numerical tests to determine the adequacy of this specification to prevent the occurrence of seismic pounding between steel frame structures under near-field and far-field earthquakes. The results indicated that the recommended minimum separation gap based on the Australian Standard is inaccurate if low-rise structure in a coupled case is utilised under both near and far field earthquakes. The standard is adequate if a tall building is involved but only when a far-field earthquake happens. The research likewise presents results derived by using the ABS and SRSS methods.

Seismic performance enhancement of a PCI-girder bridge pier with shear panel damper plus gap: Numerical simulation

  • Andika M. Emilidardi;Ali Awaludin;Andreas Triwiyono;Angga F. Setiawan;Iman Satyarno;Alvin K. Santoso
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.69-82
    • /
    • 2024
  • In the conventional seismic design approach for a bridge pier, the function of the stopper, and shear key are to serve as mechanisms for unseating prevention devices that retain and transmit the lateral load to the pier under strong earthquakes. This frequently inflicts immense shear forces and bending moments concentrated at the plastic hinge zone. In this study, a shear panel damper plus gap (SPDG) is proposed as a low-cost alternative with high energy dissipation capacity to improve the seismic performance of the pier. Therefore, this study aimed to investigate the seismic performance of the pre-stressed concrete I girder (PCI-girder) bridge equipped with SPDG. The bridge structure was analyzed using nonlinear time history analysis with seven-scaled ground motion records using the guidelines of ASCE 7-10 standard. Consequently, the implementation of SPDG technology on the bridge system yielded a notable decrease in maximum displacement by 41.49% and a reduction in earthquake input energy by 51.05% in comparison to the traditional system. This indicates that the presence of SPDG was able to enhance the seismic performance of the existing conventional bridge structure, enabling an improvement from a collapse prevention (CP) level to an immediate occupancy (IO).

Parametric study on earthquake induced pounding between adjacent buildings

  • Naserkhaki, Sadegh;Abdul Aziz, Farah N.A.;Pourmohammad, Hassan
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.503-526
    • /
    • 2012
  • Pounding between closely located adjacent buildings is a serious issue of dense cities in the earthquake prone areas. Seismic responses of adjacent buildings subjected to earthquake induced pounding are numerically studied in this paper. The adjacent buildings are modeled as the lumped mass shear buildings subjected to earthquake acceleration and the pounding forces are modeled as the Kelvin contact force model. The Kelvin model is activated when the separation gap is closed and the buildings pound together. Characteristics of the Kelvin model are extensively explored and a new procedure is proposed to determine its stiffness. The developed model is solved numerically and a SDOF pounding case as well as a MDOF pounding case of multistory adjacent buildings are elaborated and discussed. Effects of different separation gaps, building heights and earthquake excitations on the seismic responses of adjacent buildings are obtained. Results show that the seismic responses of adjacent buildings are affected negatively by the pounding. More stories pound together and pounding is more intense if the separation gap is smaller. When the height of buildings differs significantly, the taller building is almost unaffected while the shorter building is affected detrimentally. Finally, the buildings should be analyzed case by case considering the potential earthquake excitation in the area.

지진하중에 의한 제어봉구동장치 내진지지판의 비선형 충격해석 (Nonlinear Impact Analysis of CEDM Seismic Cap Plates for Seismic Loading)

  • 강태교;김태형;이대희;최택상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.435-440
    • /
    • 2004
  • The nonlinear impacts between the Control Element Drive Mechanisms (CEDMs) seismic cap plates installed on the CEDM top of a pressurized water reactor are studied with the dynamically reduced models of the CEDM and Integrated Head Assembly (IHA). It is important to develope nonlinear models considering the gap effects between the plates. In order to simulate impacts, reduced models for the primary structures, such as CEDM and IHA, are developed through simplifying detailed models, and the nonlinear structural analysis is performed under seismic loading conditions. The responses are examined in various gap sizes depending on the reactor operating conditions.

  • PDF

Mitigation of seismic collision between adjacent structures using roof water tanks

  • Mahmoud, Sayed
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.171-184
    • /
    • 2020
  • The potential of using the roof water tanks as a mitigation measure to minimize the required separation gap and induced pounding forces due to collisions is investigated. The investigation is carried out using nonlinear dynamic analysis for two adjacent 3-story buildings with different dynamic characteristics under two real earthquake motions. For such analysis, nonlinear viscoelastic model is used to simulate forces due to impact. The sloshing force due to water movement is modelled in terms of width of the water tank and the instantaneous wave heights at the end wall. The effect of roof water tanks on the story's responses, separation gap, and magnitude and number of induced pounding forces are investigated. The influence of structural stiffness and storey mass are investigated as well. It is found that pounding causes instantaneous acceleration pulses in the colliding buildings, but the existence of roof water tanks eliminates such acceleration pulses. At the same time the water tanks effectively reduce the number of collisions as well as the magnitude of the induced impact forces. Moreover, buildings without constructed water tanks require wider separation gap to prevent pounding as compared to those with water tanks attached to top floor under seismic excitations.

Seismic damage mitigation of bridges with self-adaptive SMA-cable-based bearings

  • Zheng, Yue;Dong, You;Chen, Bo;Anwar, Ghazanfar Ali
    • Smart Structures and Systems
    • /
    • 제24권1호
    • /
    • pp.127-139
    • /
    • 2019
  • Residual drifts after an earthquake can incur huge repair costs and might need to replace the infrastructure because of its non-reparability. Proper functioning of bridges is also essential in the aftermath of an earthquake. In order to mitigate pounding and unseating damage of bridges subjected to earthquakes, a self-adaptive Ni-Ti shape memory alloy (SMA)-cable-based frictional sliding bearing (SMAFSB) is proposed considering self-adaptive centering, high energy dissipation, better fatigue, and corrosion resistance from SMA-cable component. The developed novel bearing is associated with the properties of modularity, replaceability, and earthquake isolation capacity, which could reduce the repair time and increase the resilience of highway bridges. To evaluate the super-elasticity of the SMA-cable, pseudo-static tests and numerical simulation on the SMA-cable specimens with a diameter of 7 mm are conducted and one dimensional (1D) constitutive hysteretic model of the SMAFSB is developed considering the effects of gap, self-centering, and high energy dissipation. Two types of the SMAFSB (i.e., movable and fixed SMAFSBs) are applied to a two-span continuous reinforced concrete (RC) bridge. The seismic vulnerabilities of the RC bridge, utilizing movable SMAFSB with the constant gap size of 60 mm and the fixed SMAFSBs with different gap sizes (e.g., 0, 30, and 60 mm), are assessed at component and system levels, respectively. It can be observed that the fixed SMAFSB with a gap of 30 mm gained the most retrofitting effect among the three cases.

Test for the influence of socket connection structure on the seismic performance of RC prefabricated bridge piers

  • Yan Han;Shicong Ding;Yuxiang Qin;Shilong Zhang
    • Earthquakes and Structures
    • /
    • 제25권2호
    • /
    • pp.89-97
    • /
    • 2023
  • In order to obtain the impact of socket connection interface forms and socket gap sizes on the seismic performance of reinforced concrete (RC) socket prefabricated bridge piers, quasi-static tests for three socket prefabricated piers with different column-foundation connection interface forms and reserved socket gap sizes, as well as to the corresponding cast-in-situ reinforced concrete piers, were carried out. The influence of socket connection structure on various seismic performance indexes of socket prefabricated piers was studied by comparing and analyzing the hysteresis curve and skeleton curve obtained through the experiment. Results showed that the ultimate failure mode of the socket prefabricated pier with circumferential corrugated treatment at the connection interface was the closest to that of the monolithic pier, the maximum bearing capacity was slightly less than that of the cast-in-situ pier but larger than that of the socket pier with roughened connection interface, and the displacement ductility and accumulated energy consumption capacity were smaller than those of socket piers with roughened connection interface. The connection interface treatment form had less influence on the residual deformation of socket prefabricated bridge piers. With the increase in the reserved socket gap size between the precast pier column and the precast foundation, the bearing capacity of the prefabricated socket bridge pier component, as well as the ductility and residual displacement of the component, would be reduced and had unfavorable effect on the energy dissipation property of the bridge pier component.

수조내 사각단면 구조물의 미끄럼 지진응답 특성 (Seismic Sliding Characteristics of Rectangular Structures Submerged in a Rectangular Pool)

  • 신태명;이희남
    • 소음진동
    • /
    • 제8권2호
    • /
    • pp.260-266
    • /
    • 1998
  • 수조 내에 잠긴 구조물에 대한 미끄럼 지진응답의 해석시 비선형 모델에 포함되는 유체동적 효과를 계산할 때에 종래의 방법은 수조와 구조물 사이의 초기 간격 조건만으로 계산한 다음, 이를 지진 작용 시간동안 일정한 값으로 가정하여 사용하였다. 이는 지진시 수중구조물의 예상변위가 유체 간격에 비해 아주 작다고 가정하였기 때문이다. 그러나 유체 간격이 비교적 크지 않은 조건에서는 이 방법은 자칫 비보수적인 결과를 초래할 수 있다. 본 논문에서는 건물내 수조에 잠긴 구조물에 대한 지진해석의 한가지 예를 통하여 어떠한 경우 얼마나 미끄럼변위를 과소평가 할 수 있는지를 보인다. 그리고, 이러한 경우 최대 미끄럼변위의 예측시 예상되는 과도한 오차를 피하기 위하여는 시간적분을 위한 각 적분 단위시간마다 유체동적 효과를 지속적으로 계산하여 개정하여 주어야 한다는 사실을 확인하였다.

  • PDF

Assessing the effect of inherent nonlinearities in the analysis and design of a low-rise base isolated steel building

  • Varnavaa, Varnavas;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • 제5권5호
    • /
    • pp.499-526
    • /
    • 2013
  • Seismic isolation is an effective method for the protection of buildings and their contents during strong earthquakes. This research work aims to assess the appropriateness of the linear and nonlinear models that can be used in the analysis of typical low-rise base isolated steel buildings, taking into account the inherent nonlinearities of the isolation system as well as the potential nonlinearities of the superstructure in case of strong ground motions. The accuracy of the linearization of the isolator properties according to Eurocode 8 is evaluated comparatively with the corresponding response that can be obtained through the nonlinear hysteretic Bouc-Wen constitutive model. The suitability of the linearized model in the determination of the size of the required seismic gap is assessed, under various earthquake intensities, considering relevant methods that are provided by building codes. Furthermore, the validity of the common assumption of elastic behavior for the superstructure is explored and the alteration of the structural response due to the inelastic deformations of the superstructure as a consequence of potential collision to the restraining moat wall is studied. The usage of a nonlinear model for the isolation system is found to be necessary in order to achieve a sufficiently accurate assessment of the structural response and a reliable estimation of the required width of the provided seismic gap. Moreover, the simulations reveal that the superstructure's inelasticity should be taken into account, especially if the response of the structure under high magnitude earthquakes is investigated. The consideration of the inelasticity of the superstructure is also recommended in studies of structural collision of seismically isolated structures to the surrounding moat wall, since it affects the response.