• Title/Summary/Keyword: seismic capacity

Search Result 1,463, Processing Time 0.029 seconds

Seismic Capacity of Reinforced Concrete Frames Retrofitted with H-beam Frame (H형강 프레임으로 보강한 철근 콘크리트 골조의 내진성능 평가)

  • Kim, Min Sook;Choi, Hosoon;Song, Seung Eon;Lee, Young Hak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • This study proposed proposes a retrofitting method using an H-beam frame to improve the seismic performance of non-seismic designed reinforced concrete frames. To evaluate the seismic performance with the H-beam frames, a cyclic lateral load test was performed and the experimental result was compared with the bared frame, and a masonry infilled RC frame. The results was were analyzed regarding aspects of the load-displacement hysteresis behavior, effective stiffness, displacement ductility, and cumulative energy dissipation. AlsoIn addition, it was possible to prove both an increase of in the maximum load capacity, effective stiffness, and energy dissipation capacity using the H-beam frame.

Seismic assessment of thin steel plate shear walls with outrigger system

  • Fathy, Ebtsam
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.267-282
    • /
    • 2020
  • The seismic performance and failure modes of the dual system of moment resisting frames and thin steel plate shear walls (TSPSWs) without and with one or two outrigger trusses are studied in this paper. These structural systems were utilized to resist vertical and lateral loads of 40-storey buildings. Detailed Finite element models associated with nonlinear time history analyses were used to examine seismic capacity and plastic mechanism of the buildings. The analyses were performed under increased levels of earthquake intensities. The models with one and two outriggers showed good performance during the maximum considered earthquake (MCE), while the stress of TSPSWs in the model without outrigger reached its ultimate value under this earthquake. The best seismic capacity was in favour of the model with two outriggers, where it is found that increasing the number of outriggers not only gives more reduction in lateral displacement but also reduces stress concentration on thin steel plate shear walls at outrigger floors, which caused the early failure of TSPSWs in model with one outrigger.

Assessment of seismic strengthening solutions for existing low-rise RC buildings in Nepal

  • Chaulagain, Hemchandra;Rodrigues, Hugo;Spacone, Enrico;Varum, Humberto
    • Earthquakes and Structures
    • /
    • v.8 no.3
    • /
    • pp.511-539
    • /
    • 2015
  • The main objective of this study is to analytically investigate the effectiveness of different strengthening solutions in upgrading the seismic performance of existing reinforced concrete (RC) buildings in Nepal. For this, four building models with different structural configurations and detailing were considered. Three possible rehabilitation solutions were studied, namely: (a) RC shear wall, (b) steel bracing, and (c) RC jacketing for all of the studied buildings. A numerical analysis was conducted with adaptive pushover and dynamic time history analysis. Seismic performance enhancement of the studied buildings was evaluated in terms of demand capacity ratio of the RC elements, capacity curve, inter-storey drift, energy dissipation capacity and moment curvature demand of the structures. Finally, the seismic safety assessment was performed based on standard drift limits, showing that retrofitting solutions significantly improved the seismic performance of existing buildings in Nepal.

Seismic Capacity of a Reinforced Concrete Structure without Seismic Detailing and Implication to the Seismic Design in the Region of Moderate Seismicity (비내진상세 철근콘크리트 구조물의 내진성능 및 중약진지역 내진설계에의 적용)

  • 김익현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.305-312
    • /
    • 1999
  • A four-story reinforced concrete frame building model is designed for the gravity loads. only Static nonlinear pushover analyses are performed in two orthogonal horizontal directions. The overall capacity curves are converted into ADRS spectra and compared with demand spectra. At several points the deformed shape moment and shear distribution are calculated. It is observed that the seismic capacity may not meet the design requirements in soft soil condition and may collapse in MCE. It is concluded that limited but adequate amount of ductility need be provided in the seismic design in low to moderate seismicity regions.

  • PDF

Characteristics of Seismic Design of Concrete Structures in New Zealand Standards(NZS) (콘크리트 구조물에 대한 뉴질랜드 내진설계 규준의 특성)

  • 이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.375-382
    • /
    • 2000
  • This paper briefly summarizes the basic concepts and main characteristics of seismic design of New Zealand Standards(NZS) with regard to reinforced concrete(RC) structures. NZS used the concept of the capacity design and the limit state design to satisfy the requirements of serviceability and safety. Plastic mechanisms and details with respect to the limit state of safety are briefly presented in this paper. The understanding of this advanced seismic design concept will enable us to implement the basic theory of capacity design and contribute to the development of Korean seismic code in new generation,

  • PDF

Seismic Evaluation of Ordinary Moment Concrete Frames Using Capacity Spectrum Method (지반특성과 지진지역에 따른 보통모멘트 골조의 내진성능 평가)

  • 권건업;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.947-952
    • /
    • 2001
  • This study is to evaluate seismic performance of ordinary moment concrete frames. Base shear and roof displacement relations are obtained from the experiment of 3 story ordinary moment resisting concrete frame. The frame was designed only for gravity loads. The performance of the building is evaluated using capacity spectrum method. Five different seismic zones and three different soil types are considered. For each condition of seismic zone and soil type, ten earthquake ground motions are used to establish the demand spectrum.

  • PDF

A Study on the Seismic Response Analysis of Reinforced Concrete Building (철근콘크리트 건물의 지진응답해석에 관한 연구)

  • 한상훈;이상호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.507-512
    • /
    • 1997
  • The objective of present paper is to provide the fundamental data of earthquake-resistance design such as estimating the resistance capacity and evaluating the design seismic load. With one bending failed building, it is checked and compared between real damaged result and analysis value by means of static and dynamic analysis using multi-degree of freedom system. In this analysis, four kinds of the earthquake waves are used. Through elasto-plastic seismic response analysis of reinforced concrete building, we could estimate dynamic behaviour of building.

  • PDF

Seismic Fragility Analysis of the Structure Considering Composite Modal Damping (복합모드감쇠를 고려한 구조물의 지진취약도분석)

  • 조성국;조양희;박형기;황규호
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.200-207
    • /
    • 2001
  • This paper introduces a methodology of seismic fragility analysis and discusses the basic input variables, focusing on the conservatism and variability of reference response spectrum. The procedures to consider the composite modal damping in the seismic fragility analysis is presented and its effects on the seismic capacity of structure is evaluated through an example analysis of the nuclear power plant structure which has typical composite modal damping characteristics. Two seismic fragility analyses were performed to obtain the seismic capacities which evaluated by considering the composite modal damping and the single damping characteristics. The results showed that the seismic fragility analysis without considering the different values of composite modal damping may considerably overestimate the seismic capacity of coupled structures.

  • PDF

Experimental and numerical analysis of seismic behaviour for recycled aggregate concrete filled circular steel tube frames

  • Xianggang Zhang;Gaoqiang Zhou;Xuyan Liu;Yuhui Fan;Ercong Meng;Junna Yang;Yajun Huang
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.537-543
    • /
    • 2023
  • To study the seismic behavior of recycled aggregate concrete filled circular steel tube (RACFCST) frames, the seismic behavior experiment of RACFCST frame was carried out to measure the hysteresis curve, skeleton curve and other seismic behavior indexes. Moreover, based on the experimental study, a feasible numerical analysis model was established to analyze the finite element parameters of 8 RACFCST frame specimens, and the influence of different variation parameters on the seismic behavior index for RACFCST frame was revealed. The results showed that the skeleton curve of specimens under different axial compression ratios were divided into three stages: elastic stage, elastic-plastic stage and descending stage, and the descending stage was relatively stable, indicating that the specimen had stronger deformation capacity in the descending stage. With the increase of axial compression ratio, the peak bearing capacity of all specimens reduced gradually, and the reduction was less than 5%. With the decrease of beam-column linear stiffness ratio, the peak bearing capacity decreased gradually. With the decrease of yield bending moment ratio of beam-column, the peak bearing capacity decreased gradually, and the decreasing rate of peak bearing capacity gradually accelerated. In addition, compared with the axial compression ratio, the beam-column linear stiffness ratio and the yield bending moment ratio of beam-column had a more significant influence on the peak bearing capacity of RACFCST frame.

Seismic Resistance Response of Railway Station Building Retrofitted by Metallic Dampers (강재댐퍼를 적용한 역사 건물의 내진 응답)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.82-88
    • /
    • 2010
  • The purpose of this research is a seismic capacity evaluation and strengthening of existing railway station buildings, which were constructed before the seismic design code activated. The seismic capacity of 2nd story RC station building is evaluated by using nonlinear time-history analysis. Analysis results are checked by story drift ratio and story shear, which are described in design code. As a result, the story shears are exceeding the base shear of the design code, the appropriate seismic strengthening methods are needed. To improve the seismic capacity, metallic dampers are used. Evaluation parameters are metallic damper shape and damper installation methods. Dampers are installed in four places in X and Y directions of station buildings. By reviewing of time-history analysis results, the metallic damper, which is installed inverted K-brace type, shows a better seismic performance than other damper shape and installation methods.