• Title/Summary/Keyword: segmental retaining wall

Search Result 67, Processing Time 0.033 seconds

Analysis of Triggering Events of a Geosynthetic Wall Slope Failure within Slope Stability Perspective (사면안정측면에서의 보강토 옹벽 붕괴 요인 분석)

  • Yoo, Chung-Sik;Jung, Hye-Young;Jung, Hyuk-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.207-215
    • /
    • 2005
  • This paper presents a case history of a geosynthetics-reinforced segmental retaining wall, which collapsed during a sever rainfall immediately after the completion of the wall construction. In an attempt to identify possible causes for the collapse, a comprehensive investigation was carried out including physical and strength tests on the backfill, stability analyses on the as-built design based on the current design approaches, and slope stability analyses with pore pressure consideration. The investigation revealed that the inappropriate as-built design and the bad-quality backfill were mainly responsible for the collapse. This paper describes the site condition including wall design, details of the results of investigation and finally, lessons learned. Practical significance of the findings from this study is also discussed.

  • PDF

Research on the railroad reinforcement subgrade with short reinforcement and rigid facing (강성벽체와 단보강재를 갖는 철도보강노반에 대한 연구)

  • Kim, Dang-Sang;Kim, Ki-Hwan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.350-358
    • /
    • 2009
  • To enhance the application of the reinforced retaining walls in the railway industry, this paper suggested a type of reinforcement subgrade with short reinforcement and rigid facing. To become popular the reinforced retaining walls in the industry, the deformation of retaining walls should be controlled below some limited level. In this paper, small scale and full scale tests of the proposed retaining walls were performed and their deformation characteristics were evaluated. Even though it has short reinforcement, the rigid type retaining wall had small deformation to the external train loading than the segmental type retaining wall had.

  • PDF

Behavior of a Geosynthetic Reinforced Two-tier Segmental Retaining Wall on a Yielding Foundation (압축성이 큰 지반 위에 시공되는 계단형 블록식 보강토 옹벽의 거동)

  • Yoo Chung-Sik;Jeon Han-Yong
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.7
    • /
    • pp.21-29
    • /
    • 2005
  • This paper presents the results of a numerical investigation on the behavior of a geosynthetic reinforced two-tier segmental retaining wall (GR-SRW) on a yielding foundation. A hypothetical 10 m high two tier GR-SRW to be constructed on an incompetent foundation containing a layer of relative soft soil deposit was considered. A verified finite-element procedure was employed to get insights into the effect of foundation yielding on the wall behavior including the wall deformation and the reinforcement load. It is shown that the effect of foundation yielding is to increase the wall deformation as well as the reinforcement load, thus influencing both the internal as well as the external stability of the wall. Practical implications of the findings obtained from this study are highlighted in this paper.

A Study on Behavior Characteristics of Segmental Retaining Wall (조립식 블럭 옹벽의 거동특성에 관한 연구)

  • Lee, Jundae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.4
    • /
    • pp.15-21
    • /
    • 2008
  • From the practical point of view, general retaining wall systems, such as gravity wall, cantilever wall and reinforced wall, have several problems. As a countermeasure, precast block type retaining wall systems have been developed and used for the various purposes of construction. The retaining wall systems can be applied not only for mechanical purpose but environmentally friendly aspects by changing the shapes of surface plates and planting on the surface plates. On the other hand, the bulging failure was dominant near the center of wall height. Therefore, an individual block has to be estimated for the stability problem related to turnover and the for design of gravity block type wall. On the basis of this result, the optimum section of the wall has to be determined.

  • PDF

Internal Stability of Timber Framed Earth Retaining Wall (목재옹벽의 내적안정 평가에 관한 연구)

  • Lee, Kwang-Wu;Kim, Ju-Hyong;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.81-89
    • /
    • 2011
  • This paper introduces a recently developed thinning-out timber framed earth retaining wall system. Timber framed retaining walls are usually designed by using design code of gravity type retaining wall but internal stability of timber framed earth retaining walls is often neglected. In this study, it is recommended to use the design code for segmental retaining walls by National Concrete Masonry Association (NCMA, 1997) to check internal stability of timber framed earth retaining wall. Based on the several shear test results for 3 types of timber frames, a simple design chart including internal stability is suggested.

Soil-Reinforced Segmental Retaining Walls in Tiered Arrangement - Case Study (계단식 보강토 옹벽의 설계 사례 고찰)

  • 유충식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.541-548
    • /
    • 2002
  • This paper presents the results of stability analyses on soil-reinforced segmental retaining walls in a tiered arrangement. As-built design sections of four different walls were analyzed within the context of the limit equilibrium-based current design guidelines. The appropriateness of the original designs were then evaluated. Slope stability analyses against the compound failure mode, which Is frequently Ignored during design, were additionally peformed based on the method recommended by FHWA design guideline. The results indicate that the as-built designs of most of the walls examined do not meet the minimum factors of safety for the external and internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

  • PDF

Rainfall and Performance of Soil-Reinforced Regtaining Wall - Investigation on Case Histories (강우와 보강토 옹벽의 거동 - 시공 및 붕괴사례 고찰)

  • Yoo, Chung-Sik;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.3
    • /
    • pp.17-24
    • /
    • 2006
  • This paper presents the two field walls that demonstrate the effect of rainfall on the performance of soil-reinforced retaining wall. A field test wall constructed in Geotechnical Experimental Site at Sungkyunkwan University has been monitored for more than 8 months to study the long-term behavior of soil-reinforced retaining wall. The measured data showed a good correlation between rainfall and wall movement after wall completion. A case of failed soil-reinforced retaining wall also is presented to highlight the effect of rainfall on the performance of soil-reinforced retaining wall. Implications of the findings are discussed.

  • PDF

Investigation on Effect of Rainfall on Performance of Soil-Reinforced Regtaining Wall (강우가 보강토 옹벽의 거동에 미치는 영향에 관한 연구)

  • Yoo, Chung-Sik;Jung, Hyuk-Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.2 no.3
    • /
    • pp.47-55
    • /
    • 2003
  • This paper presents the two field walls that demonstrate the effect of rainfall on the performance of soil-reinforced retaining wall. A field test wall constructed in Geotechnical Experimental Site at Sungkyunkwan University has been monitored for more than 8 months to study the long-term behavior of soil-reinforced retaining wall. The measured data showed a good correlation between rainfall and wall movement after wall completion. A case of failed soil-reinforced retaining wall also is presented to highlight the effect of rainfall on the performance of soil-reinforced retaining wall. Implications of the findings are discussed.

  • PDF

Design Case Study of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration (다단식 보강토 옹벽의 설계 사례 연구)

  • 유충식;허병주
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.6
    • /
    • pp.115-125
    • /
    • 2003
  • This paper presents the results of design case study on soil-reinforced segmental retaining walls in tiered configuration. Six different field walls were examined to investigate the appropriateness of their designs within the context of the current design guidelines based on limit equilibrium. Slope stability analysis against the compound failure mode, which is frequently ignored during design, was additionally performed based on the method recommended by FHWA design guidelines. The results indicate that the as-built designs of some of the walls examined do not meet the minimum factors of safety for the external and Internal stabilities, and for the compound failure mode. The implications of the findings from this study are discussed.

Geosynthetic Reinforced Segmental Retaining Wall Failure Buying Heavy Rainfall - A Case Study (집중강우시 발생한 블록식 보강토 옹벽의 붕괴사례)

  • Yoo Chung-Sik;Jeon Han-Yong;Jung Hye-Young;Jung Hyuk-Sang
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.4
    • /
    • pp.135-143
    • /
    • 2005
  • This paper presents a case history of a geosynthetics-reinforced segmental retaining wall, which collapsed during a severe rainfall immediately after the completion of the wall construction. In an attempt to identify possible causes for the collapse, a comprehensive investigation was carried out including physical and strength tests on the backfill, stability analyses on the as-built design based on the current design approaches, and slope stability analyses with pore pressure consideration. The investigation revealed that the inappropriate as-built design and the bad-quality backfill were mainly responsible for the collapse. This paper describes the site condition including wall design, details of the results of investigation and finally, lessons learned. Practical significance of the findings from this study is also discussed.