• 제목/요약/키워드: section model tests

검색결과 293건 처리시간 0.023초

A STUDY ON NUMERICAL COUPLING BETWEEN MECHANICAL AND HYDRAULIC BEHAVIORS IN A GRANITE ROCK MASS SUBJECT TO HIGH-PRESSURE INJECTION

  • Jeong, Woo-Chang;Jai-Woo;Song, Jai-Woo
    • Water Engineering Research
    • /
    • 제2권2호
    • /
    • pp.123-138
    • /
    • 2001
  • An injection experiment was carried ut to investigate the pressure domain within which hydromechanical coupling influences considerably the hydrologic behavior of a granite rock mass. The resulting database is used for testing a numerical model dedicated to the analysis of such hydromechanical interactions. These measurements were performed in an open hole section, isolated from shallower zones by a packer set at a depth of 275 m and extending down to 840 m. They consisted in a series of flow meter injection tests, at increasing injection rates. Field results showed that conductive fractures from a dynamic and interdependent network, that individual fracture zones could not be adequately modeled as independent systems, that new fluid intakes zones appeared when pore pressure exceeded the minimum principal stress magnitude in that well, and that pore pressures much larger than this minimum stress could be further supported by the circulated fractures. These characteristics give rise to the question of the influence of the morphology of the natural fracture network in a rock mass under anisotropic stress conditions on the effects of hydromechanical couplings.

  • PDF

A simplified approach for fire-resistance design of steel-concrete composite beams

  • Li, Guo-Qiang;Wang, Wei-Yong
    • Steel and Composite Structures
    • /
    • 제14권3호
    • /
    • pp.295-312
    • /
    • 2013
  • In this paper, a simplified approach based on critical temperature for fire resistance design of steel-concrete composite beams is proposed. The method for determining the critical temperature and fire protection of the composite beams is developed on the basis of load-bearing limit state method employed in current Chinese Technical Code for Fire safety of Steel Structure in Buildings. Parameters affecting the critical temperature of the composite beams are analysed. The results show that at a definite load level, section shape of steel beams, material properties, effective width of concrete slab and concrete property model have little influence on the critical temperature of composite beams. However, the fire duration and depth of concrete slab have significant influence on the critical temperature. The critical temperatures for commonly used composite beams, at various depth of concrete and fire duration, are given to provide a reference for engineers. The validity of the practical approach for predicting the critical temperature of the composite beams is conducted by comparing the prediction of a composite beam with the results from some fire design codes and full scale fire resistance tests on the composite beam.

Numerical studies of the suppression of vortex-induced vibrations of twin box girders by central grids

  • Li, Zhiguo;Zhou, Qiang;Liao, Haili;Ma, Cunming
    • Wind and Structures
    • /
    • 제26권5호
    • /
    • pp.305-315
    • /
    • 2018
  • A numerical study based on a delayed detached eddy simulation (DDES) is conducted to investigate the aerodynamic mechanism behind the suppression of vortex-induced vibrations (VIVs) of twin box girders by central grids, which have an inhibition effect on VIVs, as evidenced by the results of section model wind tunnel tests. The mean aerodynamic force coefficients with different attack angles are compared with experimental results to validate the numerical method. Next, the flow structures around the deck and the aerodynamic forces on the deck are analyzed to enhance the understanding of the occurrence of VIVs and the suppression of VIVs by the application of central grids. The results show that shear layers are separated from the upper railings and lower overhaul track of the upstream girder and induce large-scale vortices in the gap that cause periodical lift forces of large amplitude acting on the downstream girder, resulting in VIVs of the bridge deck. However, the VIVs are apparently suppressed by the central grids because the vortices in the central gap are reduced into smaller vortices and become weaker, causing slightly fluctuating lift forces on the deck. In addition, the mean lift force on the deck is mainly caused by the upstream girder, whereas the fluctuating lift force is mainly caused by the downstream girder.

Seismic performance of high strength reinforced concrete columns

  • Bechtoula, Hakim;Kono, Susumu;Watanabe, Fumio
    • Structural Engineering and Mechanics
    • /
    • 제31권6호
    • /
    • pp.697-716
    • /
    • 2009
  • This paper summarizes an experimental and analytical study on the seismic behavior of high strength reinforced concrete columns under cyclic loading. In total six cantilever columns with different sizes and concrete compressive strengths were tested. Three columns, small size, had a $325{\times}325$ mm cross section and the three other columns, medium size, were $520{\times}520$ mm. Concrete compressive strength was 80, 130 and 180 MPa. All specimens were designed in accordance with the Japanese design guidelines. The tests demonstrated that, for specimens made of 180 MPa concrete compressive strength, spalling of cover concrete was very brittle followed by a significant decrease in strength. Curvature was much important for the small size than for the medium size columns. Concrete compressive strength had no effect on the curvature distribution for a drift varying between -2% and +2%. However, it had an effect on the drift corresponding to the peak moment and on the equivalent viscous damping variation. Simple equations are proposed for 1) evaluating the concrete Young's modulus for high strength concrete and for 2) evaluating the moment-drift envelope curves for the medium size columns knowing that of the small size columns. Experimental moment-drift and axial strain-drift histories were well predicted using a fiber model developed by the authors.

변위 시계열 데이터를 이용한 교량거더의 Flutter 계수 추정기법에 관한 연구 (A Study on the Identification Method for Flutter Derivatives of Bridge Girders using Displacement Time History Data)

  • 이재형;민원;이용재
    • 한국강구조학회 논문집
    • /
    • 제13권5호
    • /
    • pp.525-533
    • /
    • 2001
  • 교량의 내풍 안전성을 평가하기 위해서는 플러터 계수(Flutter Derivatives)의 안정적 추정이 필요하다. 본 논문에서는 풍동실험에서 얻어지는 시간영역에서의 데이터중 변위 시계열데이터를 이용해서 플러터 계수를 구하는 동특성 계수 측정기법 2가지를 검토하였다. 검토된 MITD(Modified Ibrahim Time Domain) 방법과 AKF(Adaptive Kalman Filtering) 방법은 2차원단면모형 실험으로부터 동시에 8개의 플러터 계수를 산출할 수 있는 유용한 방법이다. 제안된 방법의 실제상황에서의 적용성을 검토하기 위해서 Bandlimited Gausian white noise을 가상의 데이터에 첨가하여 수학적 시뮬레이션으로 잡음에 대한 안정성을 검증해 보았다. 그 결과 교량의 플러터 해석에서는 본 연구에서 검증된 MITD 방법을 통한 플러터 계수의 산출이 추전된다.

  • PDF

Flexural Behavior of Continuous Composite Bridges with Precast Concrete Decks

  • Chung, Chul-Hun
    • 콘크리트학회논문집
    • /
    • 제15권4호
    • /
    • pp.625-633
    • /
    • 2003
  • For the construction of open-topped steel box girder bridges, prefabricated concrete slab could offer several advantages over cast-in-situ deck including good quality control, fast construction, and elimination of the formwork for concrete slab casting. However, precast decks without reinforcements at transverse joints between precast slabs should be designed to prevent the initiation of cracking at the joints, because the performance of the joint is especially crucial for the integrity of a structural system. Several prestressing methods are available to introduce proper compression at the joints, such as internal tendons, external tendons and support lowering after shear connection. In this paper, experimental results from a continuous composite bridge model with precast decks are presented. Internal tendons and external tendons were used to prevent cracking at the joints. Judging from the tests, precast decks in negative moment regions have the whole contribution to the flexural stiffness of composite section under service loads if appropriate prestressing is introduced. The validity of the calculation of a cracking load fur serviceability was presented by comparing an observed cracking load and the calculated value. Flexural behavior of the continuous composite beam with external prestressing before and after cracking was discussed by using the deflection and strain data.

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권1호
    • /
    • pp.1-13
    • /
    • 2017
  • PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.

Performance of steel beams strengthened with pultruded CFRP plate under various exposures

  • Gholami, M.;Sam, A.R. Mohd;Marsono, A.K.;Tahir, M.M.;Faridmehr, I.
    • Steel and Composite Structures
    • /
    • 제20권5호
    • /
    • pp.999-1022
    • /
    • 2016
  • The use of Carbon Fiber Reinforced Polymer (CFRP) to strengthen steel structures has attracted the attention of researchers greatly. Previous studies demonstrated bonding of CFRP plates to the steel sections has been a successful method to increase the mechanical properties. However, the main limitation to popular use of steel/CFRP strengthening system is the concern on durability of bonding between steel and CFRP in various environmental conditions. The paper evaluates the performance of I-section steel beams strengthened with pultruded CFRP plate on the bottom flange after exposure to diverse conditions including natural tropical climate, wet/dry cycles, plain water, salt water and acidic solution. Four-point bending tests were performed at specific intervals and the mechanical properties were compared to the control beam. Besides, the ductility of the strengthened beams and distribution of shear stress in adhesive layer were investigated thoroughly. The study found the adhesive layer was the critical part and the performance of the system related directly to its behavior. The highest strength degradation was observed for the beams immersed in salt water around 18% after 8 months exposure. Besides, the ductility of all strengthened beams increased after exposure. A theoretical procedure was employed to model the degradation of epoxy adhesive.

Numerical study of concrete-encased CFST under preload followed by sustained service load

  • Li, Gen;Hou, Chao;Han, Lin-Hai;Shen, Luming
    • Steel and Composite Structures
    • /
    • 제35권1호
    • /
    • pp.93-109
    • /
    • 2020
  • Developed from conventional concrete filled steel tubular (CFST) members, concrete-encased CFST has attracted growing attention in building and bridge practices. In actual construction, the inner CFST is erected prior to the casting of the outer reinforced concrete part to support the construction preload, after which the whole composite member is under sustained service load. The complex loading sequence leads to highly nonlinear material interaction and consequently complicated structural performance. This paper studies the full-range behaviour of concrete-encased CFST columns with initial preload on inner CFST followed by sustained service load over the whole composite section. Validated against the reported data obtained from specifically designed tests, a finite element analysis model is developed to investigate the detailed structural behaviour in terms of ultimate strength, load distribution, material interaction and strain development. Parametric analysis is then carried out to evaluate the impact of significant factors on the structural behaviour of the composite columns. Finally, a simplified design method for estimating the sectional capacity of concrete-encased CFST is proposed, with the combined influences of construction preload and sustained service load being taken into account. The feasibility of the developed method is validated against both the test data and the simulation results.

대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전 (Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT))

  • 안종우;김건도;김기섭;박영하
    • 대한조선학회논문집
    • /
    • 제52권6호
    • /
    • pp.428-434
    • /
    • 2015
  • The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.