Browse > Article
http://dx.doi.org/10.12989/sem.2009.31.6.697

Seismic performance of high strength reinforced concrete columns  

Bechtoula, Hakim (National Earthquake Engineering Center, C.G.S)
Kono, Susumu (Department of Architecture and Architectural Engineering, Kyoto University)
Watanabe, Fumio (Department of Architecture and Architectural Engineering, Kyoto University)
Publication Information
Structural Engineering and Mechanics / v.31, no.6, 2009 , pp. 697-716 More about this Journal
Abstract
This paper summarizes an experimental and analytical study on the seismic behavior of high strength reinforced concrete columns under cyclic loading. In total six cantilever columns with different sizes and concrete compressive strengths were tested. Three columns, small size, had a $325{\times}325$ mm cross section and the three other columns, medium size, were $520{\times}520$ mm. Concrete compressive strength was 80, 130 and 180 MPa. All specimens were designed in accordance with the Japanese design guidelines. The tests demonstrated that, for specimens made of 180 MPa concrete compressive strength, spalling of cover concrete was very brittle followed by a significant decrease in strength. Curvature was much important for the small size than for the medium size columns. Concrete compressive strength had no effect on the curvature distribution for a drift varying between -2% and +2%. However, it had an effect on the drift corresponding to the peak moment and on the equivalent viscous damping variation. Simple equations are proposed for 1) evaluating the concrete Young's modulus for high strength concrete and for 2) evaluating the moment-drift envelope curves for the medium size columns knowing that of the small size columns. Experimental moment-drift and axial strain-drift histories were well predicted using a fiber model developed by the authors.
Keywords
column; high strength concrete; performance; scale effect; damping factor; curvature; capacity; damage;
Citations & Related Records

Times Cited By Web Of Science : 6  (Related Records In Web of Science)
Times Cited By SCOPUS : 7
연도 인용수 순위
1 ACI Committee 363 (2005), "High-strength concrete (ACI 363R)" by ACI Committee 363 – High-Strength Concrete, Seventh International Symposium on the Utilization of High-Strength/High-Performance Concrete, Special publication SP-228-5, Washington, D.C., USA
2 ACI (2002), "American concrete institute building code requirements for structural concrete (ACI 318-02) and commentary (ACI 318R-02)", Reported by ACI Committee 318
3 AIJ (1999), "Design guidelines for earthquake resistant reinforced concrete buildings based on inelastic concept", Architecture Institute of Japan
4 Bechtoula, H. (2005), "Seismic performance of moderate or low rise reinforced concrete frame buildings", PhD thesis, Department of Architecture and Architectural Engineering, Kyoto University, Japan
5 Bechtoula, H., Kono, S., Sakashita, M. and Watanabe, F. (2003), "Effect of number of cycles on damage progress for large scale columns under multiaxial loadings", Proc. Japan Concrete Institute, JCI, Kyoto, 25(2), 355-360
6 JICE (1988-1993), "New RC research development report (1988-1993)", Japan Institute of Construction Engineering
7 Kumagai, H., Tozawa, M. and Kurose, Y. (2005), "Compression failure in reinforced concrete shear wall with ultra-high-strength materials", Concrete Res. Technol., JCI, 16(3), 39   DOI
8 Kuramoto, H., Kabeyasawa, T. and Shen, F.H. (1995), "Influence of axial deformation on ductility of highstrength reinforced concrete columns under varying triaxial forces", ACI Struct. J., 92(5), 610-618   ScienceOn
9 Martinez, S., Nilson, A.H. and Slate, F.O. (1982), "Spirally reinforced high strength concrete column", Research Report ${N^{\circ}}$.82-10, Department of Structural Engineering, Cornell University, Ithaca, August
10 Muguruma, H. and Watanabe, F. (1990), "Ductility improvement of high-strength concrete columns with lateral confinement", Proceeding of the Second International Symposium on Utilization of High-Strength Concrete, University of California, Berkeley, May 20-23
11 Namiki, S., Sawai, N., Kuroha, K. and Hara, T. (1999), "Application of high-strength concrete with 1000 kgf/cm2 to high-rise building", Concrete Journal, 37(3), 35-38   DOI
12 Nakamura, T. and Yokoo, Y. (1977), "Non-stationary hysteresis uniaxial stress-strain relations of wide flange steel: Part II-Empirical formulas", Transaction of the Architectural Institute of Japan, AIJ, 260, 71-82   DOI
13 Nishiyama, M. (1993), "Axial loading test on high strength concrete prisms confined by ordinary and high strength steel", Utilization of High Strength Concrete, Proceeding of High Strength Concrete Symposium, Norway, 322-329
14 Tomosawa, F. and Noguchi, T. (1995), "Relationship between compressive strength and modulus of elasticity of high strength concrete”, J. Struct. Constr. Eng., AIJ, 474, 1-10
15 Popovics, S. (1997), "A numerical approach to the complete stress-strain curve of concrete", Cement Concrete Res., 3(5), 583-599   DOI   ScienceOn
16 Sakino, K. and Sun, Y. (1194), "Stress-strain curve of concrete confined by rectilinear hops", J. Struct. Construct. Eng., AIJ, 461, 95-104
17 Shibata, A. and Sozen, M.A. (1976), "Substitute-structure method for seismic design in R/C", J. Struct. Div., ASCE, 102(ST1), 1-18