• Title/Summary/Keyword: secondary fluid

Search Result 448, Processing Time 0.024 seconds

Altered Expression of Aquaporins in Rat Submandibular Glands after Parasympathetic Denervation

  • Jung, Ji-Yeon;Byun, Kang-Ok;Kim, Won-Jae
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.2
    • /
    • pp.97-101
    • /
    • 2003
  • The salivary glands produce 1.5L of fluid per day. As in other exocrine organs, the general mechanism in the salivary glands is that water movement occurs secondary to osmotic driving forces created by active salt transport. Therefore, high water permeability in the salivary glands is expected to have a variety of aquaporin (AQP), a water channel. Although some AQPs have been known to be present in the salivary glands, roles of parasympathetic nerve in AQP expression have not yet been examined. This study was designed to examine the changes of AQPs and extracellular signal-regulated kinase (ERK) in the submandibular glands after parasympathetic denervation. Right chorda-lingual nerve was cut, and each right (experiment) and left (control) submandibular gland was excised at 1, 3, 7, 14, 30 days after denervation. The denervated right submandibular glands were resulted in weight loss and morphologic changes, including cell loss and atrophy, as the time elapsed after parasympathetic denervation increased, whereas there were no histologic alteration in control side. AQP5 which is known to reside in apical membrane and secretory caraliculi of the submandibular acini were gradually underexpressed according, as the time after denervation increased. Expression of AQP4 in submandibular ductal epithelium was down-regulated after denervation. Besides, AQP3 and 8, which is known to be present in basolateral membrane of the glandular acini, were gradually underexpressed after denervation, similar to the pattern of other types. Expression of ERK, a mitogen-activated protein kinase, was downregulated after parasympathetic denervation in the submandibular gland. These results suggest that parasympathetic nervous system regulates the expression of AQPs in salivary glands, and is in part mediated by ERK pathway.

A Numerical Analysis of Hydrogen Diffusion for Hydrogen Leakage from a Fuel Cell Vehicle in a Long Road Tunnel (장대터널에서 수소연료전지 차량의 수소 누출에 대한 수소 거동의 수치해석 연구)

  • Choi, Jongrak;Hur, Nahmkeon;Lee, Moonkyu;Chang, Hyungjin;Lee, Kwangbum;Yong, Geejoong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.588-597
    • /
    • 2012
  • In the present study, the dispersion characteristics of hydrogen leakage from a Fuel Cell Vehicle (FCV) were analyzed by numerical simulation in order to assess the risk of a hydrogen leakage incident in a long road tunnel. In order to implement the worst case of hydrogen leakage, the FCV was located at the center of a tunnel, and hydrogen was completely discharged within 63 seconds. The Leakage velocity of hydrogen was adopted sub-sonic speed because that the assumption of the blockage effect of secondary device inside a vehicle. The temporal and spatial evaluation of the hydrogen concentration as well as the flammable region in a road tunnel was reported according to change of ventilation operating conditions. The hydrogen was blended by supply air form a ventilation fan, however, the hydrogen was discharged to outside in the exhaust air. It is observed that the efficiency way to eliminate of hydrogen is supply air operating condition under the hazardous hydrogen leaking incident. The present numerical analysis can be provided useful information of ventilation under the hydrogen leaking situation.

Performance Comparison of R134a Organic Rankine Cycle (ORC) Using Hot Wastewater and Surface Seawater (온배수와 표층수를 이용하는 R134a용 유기 랭킨사이클의 성능 비교)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.6
    • /
    • pp.768-773
    • /
    • 2012
  • This study was performed to find out the possibility that hot waste water from a thermoelectric power plant can be applied to Organic Rankine Cycle (ORC) by comparing the performance characteristics for use of the ocean surface water ($25^{\circ}C$) and hot waste water ($35^{\circ}C$) as a secondary fluid. The parameters considered in this study are four; superheating temperature, subcooling temperature, turbine efficiency, and pump efficiency. Main results of this study are summarized as follows : Overall efficiency of applying hot waste water to ORC is 87% higher than that of surface water. Thus it could be confirmed that hot waste water of the thermoelectric power plant can be applied to ORC.

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Simulations of fluidelastic forces and fretting wear in U-bend tube bundles of steam generators: Effect of tube-support conditions

  • Hassan, Marwan;Mohany, Atef
    • Wind and Structures
    • /
    • v.23 no.2
    • /
    • pp.157-169
    • /
    • 2016
  • The structural integrity of tube bundles represents a major concern when dealing with high risk industries, such as nuclear steam generators, where the rupture of a tube or tubes will lead to the undesired mixing of the primary and secondary fluids. Flow-induced vibration is one of the major concerns that could compromise the structural integrity. The vibration is caused by fluid flow excitation. While there are several excitation mechanisms that could contribute to these vibrations, fluidelastic instability is generally regarded as the most severe. When this mechanism prevails, it could cause serious damage to tube arrays in a very short period of time. The tubes are therefore stiffened by means of supports to avoid these vibrations. To accommodate the thermal expansion of the tube, as well as to facilitate the installation of these tube bundles, clearances are allowed between the tubes and their supports. Progressive tube wear and chemical cleaning gradually increases the clearances between the tubes and their supports, which can lead to more frequent and severe tube/support impact and rubbing. These increased impacts can lead to tube damage due to fatigue and/or wear at the support locations. This paper presents simulations of a loosely supported multi-span U-bend tube subjected to turbulence and fluidelastic instability forces. The mathematical model for the loosely-supported tubes and the fluidelastic instability model is presented. The model is then utilized to simulate the nonlinear response of a U-bend tube with flat bar supports subjected to cross-flow. The effect of the support clearance as well as the support offset are investigated. Special attention is given to the tube/support interaction parameters that affect wear, such as impact and normal work rate.

Effects of flow variation in the first stage nozzle on the performance of a partial arc admission in a steam turbine (증기터빈 1단 노즐의 조속현상이 터빈성능에 미치는 영향)

  • Yoon, In-Soo;Lee, Tae-Gu;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.3
    • /
    • pp.60-65
    • /
    • 2008
  • Power plant industry has been developed at high-capacity, high-technology, and innovation. Steam turbine became the most useful equipment that dominate more than 50% of all the world electricity production. And developed new materials of the turbine blade and extended length of the turbine last blade brought reform in steam turbine performance upgrade. In this paper, when do partial load driving in high-capacity steam turbine, optimum driving method found whether there is something. In operating steam turbine, there is a lot of loss from secondary wake and throttle of the 1st stage nozzle by the biggest leading factor that load fluctuation affects in high-pressure steam turbine performance. Effect of internal efficiency by 1 stage nozzle is the biggest here, but here fluid flow and flow analysis were not yet examined closely definitely. So, Analyzed design data and acceptance performance test result to applying subcritical pressure drum type 560 MW, supercritical-pressure once through type 500 MW, and 800 MW steam turbines actually. In conclusion, at partial load driving, partial arc admission(PAA) is more efficient than full arc admission(FAA) efficiency. This is judged by because increase being proportional with gross energy of stream that is pressure - available energy if pressure of stream that is flowed in to the turbine increases, available energy becomes maximum and turbine efficiency improves. Therefore, turbine performance is that preview that first stage performance fell if decline is serious in partial load because first stage performance changes according to load.

  • PDF

Endoscopic Surgery for Pituitary Tumor

  • Kim, Dong-Hyun;Kim, Kyu-Hong;Cho, Young-Woon;Kim, Joon-Soo;Lee, In-Chang;Bae, Sang-Do
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.1
    • /
    • pp.20-24
    • /
    • 2005
  • Objective: The purpose of this study is to assess the efficacy and advantages of an endoscopic endonasal approach for the treatment of pituitary tumors. Methods: We retrospectively analyzed the records of 31 patients with pituitary tumors having endoscopic endonasal surgery between March 1999 and August 2003. Results: Among 31 patients with pituitary adenomas, 25 (81%) patients exhibited gross total removal of tumor on postoperative MRI within 3 days after surgery. Among 6 patients removed subtotally, 2 had only radiosurgery, 3 have had periodic follow-up MRIs and one patient with large extended tumor (grade IV, Stage E) had secondary transcranial removal of tumor before radiosurgery. Postoperative complications included cerebrospinal fluid leak in 2 patients, sinusitis in 1 patient, and one patient died due to unexpected intracerebral hemorrhage on 5 days after surgery. Besides considerable experiences with this approach are needed because of narrow working channel to the sella turcica, the results of our study showed following advantages of this procedure: visualization of areas not seen with the operating microscope, elimination of oronasal complications, more functional and cosmetic outcome, and shortened operative time and hospital stay. Conclusion: The authors consider that endoscopic endonasal transsphenoidal approach provides good results with minimal invasion for patients with pituitary tumors.

Liposuction in the Treatment of Lipedema: A Longitudinal Study

  • Dadras, Mehran;Mallinger, Peter Joachim;Corterier, Cord Christian;Theodosiadi, Sotiria;Ghods, Mojtaba
    • Archives of Plastic Surgery
    • /
    • v.44 no.4
    • /
    • pp.324-331
    • /
    • 2017
  • Background Lipedema is a condition consisting of painful bilateral increases in subcutaneous fat and interstitial fluid in the limbs with secondary lymphedema and fibrosis during later stages. Combined decongestive therapy (CDT) is the standard of care in most countries. Since the introduction of tumescent technique, liposuction has been used as a surgical treatment option. The aim of this study was to determine the outcome of liposuction used as treatment for lipedema. Methods Twenty-five patients who received 72 liposuction procedures for the treatment of lipedema completed a standardized questionnaire. Lipedema-associated complaints and the need for CDT were assessed for the preoperative period and during 2 separate postoperative follow-ups using a visual analog scale and a composite CDT score. The mean follow-up times for the first postoperative follow-up and the second postoperative follow-up were 16 months and 37 months, respectively. Results Patients showed significant reductions in spontaneous pain, sensitivity to pressure, feeling of tension, bruising, cosmetic impairment, and general impairment to quality of life from the preoperative period to the first postoperative follow-up, and these results remained consistent until the second postoperative follow-up. A comparison of the preoperative period to the last postoperative follow-up, after 4 patients without full preoperative CDT were excluded from the analysis, indicated that the need for CDT was reduced significantly. An analysis of the different stages of the disease also indicated that better and more sustainable results could be achieved if patients were treated in earlier stages. Conclusions Liposuction is effective in the treatment of lipedema and leads to an improvement in quality of life and a decrease in the need for conservative therapy.

The study on the characteristics of fowl typhoid and the eradication program (가금티푸스의 특성 및 근절방안에 관한 연구)

  • Kang, Shin-Seok;Park, Jae-Myung;Lee, Jong-Jin;Yuk, Min-Jung;Byeon, Chul-Sup;Seo, Hwang-Won;Choi, Hae-Yeon
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.2
    • /
    • pp.135-144
    • /
    • 2003
  • Fowl typhoid is a septicemic disease of turkeys and chickens. The antigen is Salmonella(S) gallinarum, which cross-reacts with S pullorum because of common antigen. The organism is maintained in the ovary of carrier birds and transmitted vertically in the york. It is also transmitted horizontally through feces and broken eggs. The symptoms are weakness, drowsiness, wing drooping, hyperexcitability, paresis and diarrhea. In the many cases, the birds are found dead in the morning before any symptoms have been noticed. this experiment was carried out to investigate the characteristics of S gallanarum and scrutinized about the control systems. 1. Fowl typhoid was came about in the winter than the other seasons. The average of mortality was 46.3%. And it was came about not only adult poultry but also chicks. 2. S gallinarum was isolated from liver and spleen in infected chickens. Total isolated strains were 60. 3. The organisms were all extinct at 60$^{\circ}C$, 30mins. 4. A survival rate was higher in underground water than a secondary distilled water. It was detected in underground water until 30 days. 5. When being exposed to the solar light, it became extinct almost within 24 hours. 6. It was survived in a refrigerator until 12 months. 7. It was extinct among 5 mins in 0.1% phenol and 2% formalin. 8. When the cultured organism fluid was inoculated in SD-rat abdominal cavity, rat died within 24 hours. 9. Pullorum-typhoid related program must disciplines in order to destroy the fowl typhoid, and breeding system must be converted to cage system.

Reexpansion Pulmonary Edema (재팽창성 폐부종 3례 보고-)

  • Oh, Duck-Jin;Lee, Young;Lim, Seung-Pyeung;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.581-584
    • /
    • 1996
  • Reexpansion pulmonary edema is a rare complication of the treatment of lung collapse secondary to pneumothordx, pleural effusion, or atelectasis but occasionally life threatening. Generally, reexpansion pulmonary edema is believed to o cur only when a chronically collapsed lung is rapidly reexpanded by evacuation or large amounts of air or fluid. This complication is heralded by tachypnea, unilateral rales, and profuse expectoration of frothy secretion within several hours of reexpansion. Increased dur- ation of pneumothorax and the use o( suction are important factors in the generation of reexpansion pulmonary edema. We had experienced 3 cases of reexpansion pulmonary edema. In the two cases the pneumothorax had been present for several days, and, after insertion of a chest tube, pulmonary edema developed unilaterally but improved with supplemental oxygen. In the third case, massive pleural effusion was present. and, after insertion of a chest tube, pulmonary edema developed unilaterally, followed by cardiac arrest. He died of pulmonary edema inspire of resuscitation.

  • PDF