• 제목/요약/키워드: second harmonic

검색결과 599건 처리시간 0.025초

주파수 체배기를 이용한 K-Band용 Hair-pin 발진기 (A K-band Hair-pin Oscillator Using a Frequency Doubler)

  • 현안선;김훈석;김종헌;이종철;김남영;정원채;홍의석
    • 한국전자파학회논문지
    • /
    • 제9권6호
    • /
    • pp.833-842
    • /
    • 1998
  • 본 논문에서는 hair-pin 공진기, GaAs MESFET, 그리고 주파수 체배기로 구성된 K-Band용 발진기가 제안 되며, 하이브리드 초고주파 집적회로(HMIC) 형태로 제작되고 그 마이크로파 동작 특성이 발표된다. $\lambda_g$/4 개방 스터브가 벼ir-pin 공진 발진기의 출력인 9GHz의 기본 주파수를 억제하기 위해 주파수 체배기에서 사 용되며I 출력 정합 회로가 2차 고조파 주파수인 18 GHz에서 최적화된다. 제안된 발진기는 -083dBm의 출력, -23 dBc의 기본 주파수 억압, 그리고 18.2 GHz에서 -86 dBc/Hz의 위상 잡음을 갖는다

  • PDF

일제강점기 가정박람회에 나타난 이상주거 (Ideal Housing in the Home Exposition Under the Japanese Colonial Rule)

  • 양세화;류현주;은난순
    • 대한가정학회지
    • /
    • 제47권1호
    • /
    • pp.45-54
    • /
    • 2009
  • The purpose of the study is to examine the characteristics of the ideal housing for the modern family suggested by the Home Exposition (September, 1915) under the Japanese colonial rule in the macroscopic context of social change and the microscopic context of family. Through this research, we expect to have a partial understanding not only of changes in the outward appearance of traditional housing spaces during the civilization period and the early Japanese colonial rule when foreign cultures began to be introduced but also of families'residential lives and the patterns of change in people's consciousness of housing. Major conclusions from the current analysis are as follows. First, there were some changes in family paradigm induced through a home exhibition. Second, the most important factor for an ideal housing was that it must be the source of harmonic and healthy family life. Third, the importance of an appropriate space norm should be emphasized by providing the minimum size of each room. Fourth, the significance of the housing values of the economy, convenience, and hygiene should be emphasized for the ideal housing. Lastly, it was implied that for an ideal housing, the social and psychological aspects of housing must be satisfied along with the physical aspects. The limitation was that the model of ideal family housing presented in the Home Exposition cannot exclude the characteristics of the colonial perspectives in that it was followed by the model for the Japanese families.

컴팩트 플래쉬 방식의 휴대형 산소포화도 측정 및 ECG 감시 시스템의 구현 (Implementation of a ECG monitoring system and portable pulse oximeter for $SpO_2$ using Compact Flash Interface)

  • 김동학;김영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.19-22
    • /
    • 2002
  • In this paper, we aims to develop a microcontroll er-based ECG monitoring system and portable pulse oximeter using Compact Flash Interface. First, portable pulse oximeter system is designed to record 2 channel of biosignals simultaneously, including 1 channel of $SpO_2$ and 1 channel of pulse rate. It is very small and portable. Besides, the system makes it possible to measure a patient's condition without an additional medical equipment. We tried to solve the problems generated by a patient's motion. That is, we added an analog circuit to a traditional pulse oximeter in order to eliminate the change of the base line. And we used 2D sector algorithm. As present, SpO2 modules are completed. But there are still many further development needed in order to enhance the function. Especially, compact falsh interface remains the most to complete. Second, ECG monitoring system uses almost same as present 3-lead ECG system. But we focus on the analog part, especially in filter. The proposed filter is composed of two parts. One is a filter to remove the power-line interface. The other is a filter to remove the baseline drift. A filter to remove the power-line and the baseline drift is necessarily used in the ECG system. The implemented filter have three features; minimizing the distortion in DC component, removing the harmonic component of power-line frequency. Using compact flash interface, we can easily transfer a patient's personal information and the measured signal data to a network based server environment. That means, it is possible to implement a patient's monitoring system with low cost.

  • PDF

Fused Silica와 Al2024-T4의 비선형 파라미터 측정 (Measurement of Ultrasonic Nonlinearity Parameter of Fused Silica and Al2024-T4)

  • 강토;이택규;송성진;김학준
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.14-19
    • /
    • 2013
  • 금속 재료의 비선형 파라미터는 고유한 물성치로서 기본주파수의 음압의 크기($A_1$)과 2차고조파의 음압의 크기($A_2$)을 측정하면 산정할 수 있다. 하지만, 실험적으로 $A_1$$A_2$를 측정하는 것은 매우 복잡한 변환 과정이 필요하기 때문에 현재 많은 연구자들이 비선형 파라미터의 절대값을 측정하지 않고, 전압 변화를 관찰하는 비선형 파라미터의 상대값을 측정하고 있다. 하지만, 비선형 파라미터 상대값으로는 재료의 물성치를 대변할 수가 없기 때문에, 열화도에 따른 시편 측정에만 사용할 수 있는 제약이 있다. 따라서 본 연구에서는 정전용량 측정기법(capacitive detector)보다는 비용이 적게 소모되고 현장 적용이 가능한 압전형 수신기법(piezoelectric detection)을 이용하여 비선형 파라미터의 절대값을 측정하기 위한 시스템을 구축하였다. $A_1^2vsA_2$ 그래프로 시스템의 선형성을 검증하고 시험편인 fused silica와 Al2024-T4에 대한 비선형 파라미터를 측정하였다.

압전형 수신 기법을 이용한 초음파 절대변위진폭 측정 (Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method)

  • 박성현;김종범;장경영
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.7-12
    • /
    • 2017
  • 음향 비선형 파라미터는 입사시킨 기본주파수 성분의 변위 진폭 크기와 재료의 비선형성에 의하여 발생된 2차 고조파 성분의 변위 진폭 크기의 비로 정의된다. 본 연구에서는, 압전소자 방식을 이용한 초음파 절대변위진폭 측정의 타당성을 확인하고자, 이 기법을 통해 초음파가 입사된 SUS316 시편의 절대변위진폭을 측정하였다. 또한 비교를 위해, 레이저를 통한 패브리패럿 방식의 간섭계를 이용하여 동일 시편에 대한 절대변위진폭을 측정하였다. 두 가지 기법을 통한 실험 결과는 서로 잘 일치하는 경향을 보였으며, 특히 압전형 수신 기법의 경우 기존의 레이저 변위측정기법에 비하여 반복 측정의 안정성이 우수한 것으로 나타났다. 이 결과로부터 압전형 수신 기법은 기존 레이저 측정 기법에 비하여 과정이 복잡하지만, 미세변위를 더 안정적으로 측정할 수 있어 음향 비선형 파라미터의 측정에 유리할 것으로 기대된다.

Multimodal Nonlinear Optical Microscopy for Simultaneous 3-D Label-Free and Immunofluorescence Imaging of Biological Samples

  • Park, Joo Hyun;Lee, Eun-Soo;Lee, Jae Yong;Lee, Eun Seong;Lee, Tae Geol;Kim, Se-Hwa;Lee, Sang-Won
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.551-557
    • /
    • 2014
  • In this study, we demonstrated multimodal nonlinear optical (NLO) microscopy integrated simultaneously with two-photon excitation fluorescence (TPEF), second-harmonic generation (SHG), and coherent anti-Stokes Raman scattering (CARS) in order to obtain targeted cellular and label-free images in an immunofluorescence assay of the atherosclerotic aorta from apolipoprotein E-deficient mice. The multimodal NLO microscope used two laser systems: picosecond (ps) and femtosecond (fs) pulsed lasers. A pair of ps-pulsed lights served for CARS (817 nm and 1064 nm) and SHG (817 nm) images; light from the fs-pulsed laser with the center wavelength of 720 nm was incident into the sample to obtain autofluorescence and targeted molecular TPEF images for high efficiency of fluorescence intensity without cross-talk. For multicolor-targeted TPEF imaging, we stained smooth-muscle cells and macrophages with fluorescent dyes (Alexa Fluor 350 and Alexa Fluor 594) for an immunofluorescence assay. Each depth-sectioned image consisted of $512{\times}512$ pixels with a field of view of $250{\times}250{\mu}m^2$, a lateral resolution of $0.4{\mu}m$, and an axial resolution of $1.3{\mu}m$. We obtained composite multicolor images with conventional label-free NLO images and targeted TPEF images in atherosclerotic-plaque samples. Multicolor 3-D imaging of atherosclerotic-plaque structural and functional composition will be helpful for understanding the pathogenesis of cardiovascular disease.

경기지역 일부 고등학교 기숙사생의 급식 메뉴 만족도와 기호도 (Survey on Menu Satisfaction and Preferences of High School Boarding Students in Gyeonggi Province)

  • 신성민;배현주
    • 한국식품조리과학회지
    • /
    • 제26권4호
    • /
    • pp.347-357
    • /
    • 2010
  • This study was assessed the menu satisfaction and preferences of high school boarding students in Gyeongggido. Data collection was carried out through surveys given to 300 high school boarding students; a total of 274 were usable. Statistical analyses were done using the SAS package program (version 8.2 for Windows). The results of this study are summarized as follows: 54.0% of respondents were freshman and 46.0% were sophomores: and 52.9% of respondents were male and 47.1% were female. According to the results of the menu satisfaction survey, males and females significantly differed on appropriate food temperature, freshness of food, harmonic combination of menu, menu variety, quality of ingredients, appearance of food, and frequency of supplied nutrition information. A significant difference regarding menu satisfaction was also found between grade level. First grade students were more satisfied than second grade students. Moreover, menu preferences were significantly high for omelet-rice, fried rice, pork-on-the-bone soup, deep-fried chicken, fruit salad, spicy chinese cabbage salad kimchi, chinese cabbage kimchi, and all desserts. On the other hand, pumpkin and rice porridge, beef and rice porridge, barley rice, soft tofu stew, soybean paste soup, braised japanese spanish mackerel, and sauteed squash were not significantly preferred. The results showed that high school boarding students' menu preferences differed depending on gender, grade, and boarding period. In conclusion, the results of this study should provide dieticians information for improving menu planning. In addition, foodservice satisfaction of the boarding school students can be improved by continuous menu improvement.

메타구조의 CRLH를 이용한 이중대역 전력증폭기 설계 (Design of Dual-band Power Amplifier using CRLH of Metamaterials)

  • 고승기;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제47권12호
    • /
    • pp.78-83
    • /
    • 2010
  • 본 논문에서는 메타구조를 이용하여 하나의 RF GaN HEMT로 새로운 이중대역에 전력증폭기를 구현하였다. CRLH 전송선로는 이중- 대역 조절 특성을 갖는 메타물질 전송 선로를 만들 수 있다. CRLH 전송 선로의 이중 대역 동작은 전력증폭기의 정합 회로를 구현을 위하여 주파수 오프셋과 CRLH 전송 선로의 비선형 위상 기울기에 의해 얻을 수 있다. 이중대역에서 CRLH 전송 선로를 이용하여 이중대역에서 오직 2차, 3차 고조파 성분만을 조절하였다. 또한, 제안된 전력증폭기의 효율을 향상 시키기 위하여 출력 정합 회로뿐만 아니라 입력 정합회로도 고조파 조절 회로를 이용하여 구현하였다. 두 동작 주파수는 900MHz와 2140MHz로 정하였다. 전력증폭기의 측정된 출력 전력은 각각 900MHz에서 39.37dBm, 2140MHz에서 38.87 dB이다. 이 지점에서 얻은 전력효율 및 IMD는 900MHz에서 PAE 60.2%, IMD는 -23.17dBc, 2140MHz에서 PAE 67.3%, IMD -25.67dBc이다.

근거리 무선통신용 5.5 GHz 대역 VCO 설계 및 제작 (Design and Fabrication of 5.5 GHz VCO for DSRC)

  • 한상철;오승엽
    • 한국전자파학회논문지
    • /
    • 제12권3호
    • /
    • pp.401-408
    • /
    • 2001
  • 근거리무선통신용 RF 모듈을 구성하는 핵심 부품인 5.5 GHz 대역의 직렬 궤환형 전압 제어 발진기를 설계 및 제작하였다. MESFET의 소신호 산란계수의 발진기의 궤환부, 공진부의 Z-파라미터를 이용하여 최적 부하임피던스가 도출될때의 VCO 설계 파라미터들을 추출하였다. 최적 부하임피던스가 도출될 때 궤환부와 공진부의 리엑턴스를 구하는 프로그램은 MATKAB을 이용하여 작성하였으며 추출된 파라미터 값으로 ADS 시뮬레이터를 이용하여 비선형 대신호 해석을 하였다. 설계된 파라미터를 이용하요 구현된 전압 제어 발진기의 특성을 측정한 결과, 바랙터 다이오드에 인가되는 전압의 변화(0~5 V)에 따른 주파수 변화는 5.42 GHz~5.518 GHz이었고, 이때의 출력 레벨은 6.5dBm 이었다. 5.51 GHz 발진기 2차 고조파 억압은 -21.5dBc 이었으며 위상잡음특성은 10kHz 오프셋에서 -83.81 dBc/Hz를 얻었다. 제작된 VCO는 DSRC용 뿐만 아니라 5.8 GHz 대역의 다른 시스템에도 이용될 수 있다.

  • PDF

Cation-deficient 페로브스카이트 세라믹스의 유전 특성과 발진기 응용 (Dielectric Properties of Cation-deficient Perovskite Ceramics and Oscillator Application)

  • 김재식;최의선;류기원;이영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.18-19
    • /
    • 2006
  • In this study, dielectric properties of the ${Mg_5}{B_4}{O_{15}}$ (B=Ta, Nb) cation-deficient perovskite ceramics and its oscillator application are investigated. The cation-deficient perovskite ceramics are prepared through the solid-state route. According to the XRD pattern, ${Mg_4}{Ta_2}{O_9}$ and $Mg{Ta_2}{O_6}$ phase existed in calcined and sintered ${Mg_5}{Ta_4}{O_15}$ powder. Also ${Mg_5}{Ta_4}{O_{15}}$ phase added with increasing sintering temperature. In the case of calcined and sintered ${Mg_5}{Nb_4}{O_{15}}$ powder, single phase of ${Mg_5}{Nb_4}{O_{15}}$ is appeared. In the case of the ${Mg_5}{Ta_4}{O_{15}}$ and ${Mg_5}{Nb_4}{O_{15}}$ ceramics sintered at $1450^{\circ}C$ for 5h, the dielectric constant, quality factor, and temperature coefficient of the resonant frequency (TCRF) were 8.2, 259,473 GHz, $-10.91ppm/^{\circ}C$ and 14, 37,350 GHz, $-52.3\;ppm/^{\circ}C$, respectively. Simulated DR with ${Mg_5}{Ta_4}{O_{15}}$ ceramics had the operating frequency of 10.99 GHz and S(2,1) of -29.795 dB. Size of manufactured oscillator was $56{\times}48{\times}34\;mm^3 and operated at 11.93 GHz. Power output and second harmonic of oscillator were +13.61 dBm and -23.81 dBc at 23.85 GHz, respectively.

  • PDF