• Title/Summary/Keyword: seawater temperature

Search Result 601, Processing Time 0.026 seconds

Corrosion Properties of Duplex Stainless Steels - STS329LD and STS329J3L - for the Seawater Systems in Nuclear Power Plant

  • Chang, Hyun-Young;Park, Heung-Bae;Kim, Young-Sik;Ahn, Sang-Kon;Jang, Yoon-Young
    • Corrosion Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.60-64
    • /
    • 2011
  • Lean duplex stainless steels have been developed in Korea for the purpose of being used in the seawater systems of industry. There are also many important seawater systems in nuclear power plants. These systems supply seawater to cooling water condenser tubes, heat exchanger tubes, related pipes and chlorine injection systems. The flow velocity of some part of seawater systems in nuclear power plants is high and damages of components from corrosion are severe. The considered lean duplex stainless steels are STS329LD (20.3Cr-2.2Ni-1.4Mo) and STS329J3L (22.4Cr-5.7Ni-3Mo) and PRENs of them are 29.4 and 37.3 respectively. Physical, mechanical and micro-structural properties of them are evaluated, and electrochemical corrosion resistance is measured quantitatively in NaCl solution. Critical Pitting Temperatures (CPT)s are measured on these alloys and pit depths are evaluated using laser microscope. Long period field tests on these alloys are now being performed, and some results are going to be presented in the following study.

Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

Corrosion Characteristics of Cast Stainless Steel under Plasma Ion Nitriding Process Temperature in Marine Environment (주조 스테인리스강의 해양환경 하에서 플라즈마 이온질화 공정온도에 따른 부식특성 연구)

  • Chong, Sang-Ok;Kim, Seong-Jong
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.6
    • /
    • pp.504-509
    • /
    • 2017
  • In order to improve corrosion resistance for cast stainless steel in seawater, the characteristics of corrosion resistance after plasma ion nitriding was investigated. Plasma ion nitriding process was conducted in a mixture of nitrogen of 25% and hydrogen of 75% at substrate temperature ranging from 350 to $500^{\circ}C$ for 10 hours using pulsed-DC glow discharge plasma with working pressure of 250 Pa in vacuum condition. Corrosion tests were carried out for as-received and plasma ion nitrided specimens. The corrosion characteristics were investigated by measurement of weight loss and observation of surface morphology. In anodic polarization experiment, relatively less damage depth and weight loss were presented at a nitrided temperature of $400^{\circ}C$, attributing to the formation of S-phase.

Evolution and Origin of the Geothermal Waters in the Busan Area, Korea: 1. Cooling and Dilution by Groundwater Mixing after Heated Seawater-Rock Interaction (부산지역 지열수의 기원과 진화: 1.가열된 해수-암석 반응과 지하수의 혼입에 따른 희석과 냉각)

  • 성규열;박맹언;고용권;김천수
    • Economic and Environmental Geology
    • /
    • v.34 no.5
    • /
    • pp.447-460
    • /
    • 2001
  • The geothermal waters from the Busan area belong to Na-CI type and are characterized by much higher EC (921 ~6,520${\mu}$S/cm) and TDS (608-3,390 mg/L) than other geothermal waters in Korea. The concentration of majorions shows a weakly positive relationship with temperature except for Mg ion. The concentrations of the major cat ions have the order of Na>Ca>K>Mg. Ca ion is enriched and Mg ion is depleted compared with seawater. All Br concentrations of geothermal water are lower than those of seawater, showing a positive relationship with temperature. Generally geochemical characteristics of geothermal waters of the Busan area indicate that these waters have relatively increased Ca and Sr contents and depleted Mg, Na and K contents caused by seawater interaction with wall rock at depth during deep circulation of seawater. Base on the relationship between major ions and temperature, saline geothermal waters are diluted and are cooled by mixing of groundwaters during ascent. Isotope study and reaction path modeling of the overall geochemical system are required in order to better quantify the evolution and origin of geothermal waters in the Busan area.

  • PDF

The Estimation of Marine Environmental Capacity for the Reception of Cooling Water from HTPP in Southern Waters of Cheju Island using a 3-D Hydrodynamic Model (화순화력발전소 주변해역의 온배수 환경용량 산정)

  • Kim Gwang-Su;Choi Young-Chan;Lee Moon-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.3-12
    • /
    • 2000
  • The field surveys and the measurements of seawater temperatures were conducted every month from 1997 to 1999, and the distributions of seawater temperature were simulated and reproduced by a three dimensional hydrodynamic numerical model over the southern waters of Cheju island. In order to estimate the marine environmental capacity for the reception of the heat loads of cooling water discharged from Hwasoon Thermal Power Plant(HTPP) in the study area, the simulations for predicting the situation of unfavorable environment in which marine organisms might not be satisfied with change in seawater temperature were peformed using a three dimensional hydrodynamic numerical model by controlling quantitatively the heat loads of cooling water from HTPP Currently, HTPP discharges cooling water of 35.9℃ into the sea as much as 112,800m³/day in summer. As the results of simulations, the more the heat loads from the power plant increase, the more increase the seawater temperatures around the water areas adjacent to the power plant. In case the heat loads of cooling water from HTPP become about 5 times as high as the present loads, seawater temperatures at near-shore waters adjacent to HTPP appear to be increased to the extent of 0.5℃ above the existing seawater temperature in summer. The marine environmental capacity for the reception of thermal discharge from HTPP is estimated to be about 530×10/sup 6/kcal/day which is equivalent to the increase of a factor of 2 in the temperature of cooling water without any change in the discharge rate of cooling water or which is equivalent to the increase of a factor of 4.6 in the discharge rate of cooling water without any change in the temperature of cooling water. Comparing the case of the increase in the discharge rate of cooling water with the case of the increase in the temperature of cooling water on the basis of the same heat loads of 530×10/sup 6/kal/day, the former case is expected to increase seawater temperature a little higher and to extend the area affected by heat loads a little broader.

  • PDF

Applicability of Geophyscal Well Logging in the Assessment of Seawater Intrusion (임해지역 해수침투 평가를 위한 물리검층의 적용성)

  • Lee Sang-Gyu;Hwang Sae-Ho;Hwang Hak-Su;Park In-Hwa
    • Geophysics and Geophysical Exploration
    • /
    • v.3 no.3
    • /
    • pp.101-111
    • /
    • 2000
  • In order to assess the seawater intrusion, induction, temperature and conductivity of fluid, and natural gamma logs were obtained in nine wells at the three study areas having different hydrogeologic characteristics. Besides surface geophysical exploration, supplementary geophysical well logs were carried out to understand the hydrogeological characteristics related to the seawater intrusion in the study areas. The geophysical well logs have been proved to increase the accuracy of interpretation of the surface geophyscial exploration's data for assessment of seawater intrusion, and to get the optimum depth for a long monitoring of groundwater. They, also, revealed that the identification of hydrogeological units for strata's porosity was able to be achieved and were illustrated the applicability of geophysical well logs monitoring. Finally, geophysical well logs are expected to play to get the more quantitative information of seawater infusion, if it is fully collaborated with a better method that is strata's resistivity determination with not relatively much effected by seawater within the drilled borehole and that is the porosity measurement with built on small diameter PVC casing.

  • PDF

Distribution of Vibrio parahaemolyticus and Vibrio vulnificus in Seawater and Shellfish at Gomso Bay (곰소만의 해수 및 패류에 있어서 장염비브리오균(Vibrio parahaemolyticus)과 비브리오패혈증균(Vibrio vulnificus)의 분포)

  • Lee, Dong-Soo;Shin, Hye-Young;Park, Kwon-Sam;Shin, Il-Shik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.52 no.2
    • /
    • pp.114-120
    • /
    • 2019
  • In the case of being contaminated with pathogenic Vibrio, shellfish pose a serious threat for public health. This study was conducted to investigate the presence of Vibrio parahaemolyticus and V. vulnificus in the seawater, bottom deposit and shellfish samples collected from the Gomso Bay, west coast of Korea. V. parahaemolyticus (30-80 CFU/g) was detected from seawater Jul. to Oct. and highest at Sep. V. parahaemolyticus was detected less than 10 CFU/g from seawater at Nov. with $14.6^{\circ}C$ of seawater temperature. V. parahaemolyticus (180-1,850 CFU/g) was detected more than 100 CFU/g from 3 kinds of shellfish, Short-necked clam Ruditapes philippinarum, Corb shell Cyclina sinensis, and Surf clam Mactra veneriformis, Jul. to Oct. and was highest in Surf clam at Oct. V. parahaemolyticus was detected less than 20 CFU/g from all tested shellfish at Nov. V. vulnificus (1.8-2.7 MPN/100 mL) was detected from seawater Jul. to Oct. and was not detected at Nov. V. vulnificus (18-236.7 MPN/100 g) was also detected from 3 kinds of shellfish Jul. to Oct. and was highest in Corb shell at Jul. V. vulnificus was not detected from all tested shellfish at Nov.

Ammonia oxidation activity of nitrifying bacteria and effects of some environmental factors (질화세균의 암모니아 산화능과 이에 미치는 환경요인의 영향)

  • 송홍규;하영칠;홍순우
    • Korean Journal of Microbiology
    • /
    • v.21 no.2
    • /
    • pp.79-85
    • /
    • 1983
  • Ammonia oxidation activity of polluted water samples in Jinhae Bay and isolated strain from the seawater was investigated, and effects of environmental factors such as temperature, salinity, substrate concentration to the ammonia oxidation were also investigated. The ammonia oxidation activities of sediments, 0.01-0.04mg eq. $NO_2-N/l/h$, were exceptionally higher than that of sea water, $0.5{\sim}1{\mu}g$ eq. $NO_2-N/l/h$. the activities of muddy sediments at station 4 and 2 were 0.03~0.04mg eq. $NO_2-N/l/h$ and that of sandy sediment at station 3 was 0.002mg eq. $NO_2-N/l/h$. In the case of sea water, the activity of polluted area, station 1, was 2 times higher than that of offshore, station 4. The isolated strain reached log phase after 30days culturs and its oxidation activity was $2{\sim}3{\mu}g$ eq. $NO_2-N/day$. The maximum oxidation of ammonia by IA 13 strain occured at 30mg/l oxidation increased with the salinity rising up to 100% seawater concentraion. And temperature for maximum oxidation of ammonia was $35^{\circ}C$. the oxidation increased with the salinity rising up to 100% seawater concentration.

  • PDF

A Study on the NOx Reduction of Flue Gas Using Un-divided Electrolysis of Seawater (무격막식 해수 전기분해 방식을 통한 배연 탈질에 관한 연구)

  • Kim, Tae-Woo;Choi, Su-Jin;Kim, Jong-Hwa;Song, Ju-Yeong
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.825-829
    • /
    • 2012
  • In this study, we investigated NO oxidation characteristic that depends on available chlorine concentration and temperature of seawater which is treated by un-divided electrolysis. Reactant gas passed through bubbling reactors which is filled with electrolyzed water and then NO concentration change was analyzed. In the closed-loop electrolysis system, concentration of available chlorine increased with electrolysis time. The higher oxidation rate of NO to $NO_2$ was obtained with the higher concentration of available chlorine. Oxidation of NO was fast when temperature of electrolyzed water was high, in the case of same concentration of available chlorine.

Distribution and Molecular Characteristics of Vibrio vulnificus Isolated from Seawater Along the Gadeok Island Coast (가덕도 연안 해수에서 Vibrio vulnificus의 분포 및 분리균주의 병원성 유전자 특성)

  • Oh, Hee-Kyung;Jeong, Hee-Jin;Kim, Young-Mog
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.5
    • /
    • pp.688-693
    • /
    • 2020
  • Vibrio vulnificus is a Gram-negative marine bacterium known to cause septicemia. This study was conducted to investigate the distribution of V. vulnificus along the coast of Gadeok Island in Korea and to determine the molecular characteristics of isolated strains sampled between March and November 2019 from seawater. The strains were mostly detected between July and September, when the average water temperature and average salinity were 22.2-26.2℃ and 14.2-29.9 psu, respectively. V. vulnificus was not detected in seawater below 15℃. In September, the highest population of V. vulnificus was observed at 2,100 MPN (most probable number)/100 mL, attributable to decreased salinity from heavy rains. In addition, the detection rate of V. vulnificus was higher at the sampling station near the Nakdong River. Virulence-related genes were also identified among the isolates, such as vvhA (97.1%), viuB (44.1%), and vcgC (57.4%). In particular, viuB and vcgC were only observed in V. vulnificus isolated from June to September, when the detection rate was high and water temperature was above 20℃, suggesting the role of seasonal characteristics.