• 제목/요약/키워드: sea-salt

검색결과 527건 처리시간 0.027초

아산만의 해저지형과 해수유동 (The Circulation and the Submarine Topography in Asan Bay)

  • 장선덕
    • 수산해양기술연구
    • /
    • 제13권1호
    • /
    • pp.1-5
    • /
    • 1977
  • A series of echo-sounding and current measurements as well as the drogue and the drift bottle experiments were carried out in Asan Bay since November 1974. Several sand bars or sand flats covered by silts were developed at ebb tide in the bay. Sand waves and sand ripples were seen on the surface of the sand bars, around which sea channels of 8~ 12 meters in depth are formed. The main stream axis of the flood current which is separated into east and west branch flows southward. A cyclonic and an anticyclonic eddy are developed at the early stage of flood tide. They are transformed into a clockwise eddy before the slack water. The maximum tidal current speed observed was 3.1 ~ 3.2 knots at the entrance of the bay, while it was 1.O ~ 2.8 knots in the bay. The location of the main stream axis of the tidal current coincides well with the sea channel. A salt wedge was observed at the estuary of the Sabgyo-cheon River.

  • PDF

국내산 및 일본산 천일염의 패키징 디자인 비교 분석 (A Comparative Analysis of Packaging Design of Solar Salts Produced in Korea and Japan)

  • 강희수;민춘기;조중연;신준섭;이세은
    • 한국포장학회지
    • /
    • 제19권2호
    • /
    • pp.103-108
    • /
    • 2013
  • 본 연구는 국내와 일본에서 판매하는 소금 중 본 연구의 주 관심 대상인 천일염의 패키지 디자인 요소에 해당되는 포장재별 용량에 따른 형태와 패키지 색채 및 그래픽을 비교분석하였다. 국내산 천일염과 일본산 천일염의 패키지 디자인의 형태와 비주얼 요소들을 비교, 분석한 결과, 형태는 용량에 따라 구분이 명확하게 나타났다. 국내산 천일염은 다양한 재질과 형태의 디자인을 적용하는 반면 일본산 천일염의 경우 300 g미만은 플라스틱 소재의 스탠드 파우치형을 적용하고 300 g이상은 플라스틱 소재의 파우치형을 적용하는 것으로 나타났다. 국내산 천일염은 용량에 관계없이 플라스틱 소재의 스탠딩 파우치형을 많이 적용하고 있고 스탠딩 파우치는 개폐방식이 지퍼식으로 되어 있어서 보관이나 사용면에서 편의성이 높은 것으로 나타났다. 비주얼 요소에서 색상과 그래픽을 비교 분석한 결과, 국내산 천일염은 미네랄이 풍부하고 신안지역 섬에서 생산한다는 지역적인 특성을 살려 구체적인 염전과 염부의 그래픽을 많이 애용하고 있다. 따라서 바다의 상징적인 그래픽을 적용하는 일본과는 차별화가 뚜렷하고 색상에 있어서도 소금을 상징하는 흰색을 주조색으로 적용하고 있다. 염전과 갯벌에서 연상되는 흰색과 갈색을 통해 천일염만의 독특한 아이덴티티 색상을 나타냈다.

  • PDF

매립지하해수의 위생학적 고찰 (Microbiological Study of Aquarium Water around the Costal Sanitary landfill Sites)

  • 조용순;이인자
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.73-82
    • /
    • 1990
  • This study was conducted to investigate the vibrio sap contamination of aquarium (water) in Incheon Area The results obtained were as follows : 1. V. parahaemolyticus was detected 20.4% at samples of aquarium water and not detected at underground water 2. V. unlnificus was not detected at all samples 3. Underground water was similar to aquarium water on pH and the concentration of salt 4. Underground water proved it's safety bacteriologically 5. V. parahaemolyticus was common in the sea water between July to October.

  • PDF

항만구조물의 비파괴시험에 의한 안정성 검토 (The Evaluation of Durability by NDT test of Marine-Concrete Structures)

  • 조병완;이일근;강희풍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.169-172
    • /
    • 1995
  • Establishment of a diagnosing technology for the deterioration of reinforced concrete structures due to salt contamination is urgent, but few analytical methods based on measured data obtained from concrete structures have been presented so far. Chloride penetration into concrete from sea water is generally understood and analysed as diffusion of chloride ion. This paper presents a new method of predicting chloride penetration into concrete based on diffusion theory. Also, it determines the duralility of Marine structure in service with the prediction of remaiing lifetime by the carvonation test.

  • PDF

부산의 배경지역에 대한 $PM_{2.5}$ 미세입자 중 비해염 성분의 거동 (Behavior of Non Sea-Salt contained in $PM_{2.5}$ Fine Particles of Background Area in Busan)

  • 박기형;전보경;조정구;유수영;최금찬
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2002년도 춘계학술대회 논문집
    • /
    • pp.235-236
    • /
    • 2002
  • 대기중에는 각종 유해 중금속이 자체적으로 부유하거나, 부유분진에 흡착되어 있어 부유분진의 성분을 규명하는 것은 인체보건학적으로 중요한 일이다 특히 PM$_{2.5}$의 인체 유해성이 커서 국내에서도 대기환경기준물질로 설정이 검토되고 있다. 대기중 PM$_{2.5}$입자의 이온성분의 변화는 대기 내에서 화학적인 변화를 추적하는 실용적인 도구로서 사용되어 왔으며, 미세입자의 발생원 규명 등에 중요한 자료로서 축적되고 있다. (중략)(중략)

  • PDF

Reactive Black Dyes containing Acetoxyethyl sulfone moiety

  • Kim, Tae-Kyung;Oh, Sea-Wha;Shin, Seung-Rim
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2001년도 춘계학술발표회 논문집
    • /
    • pp.62-65
    • /
    • 2001
  • This thesis related to a reactive black dyes containing acetoxyethyl sulfone moiety which is characterized by lessening the loss of dyes in filtering process owing to the low solubility by introducing the aminophenyl- $\beta$ -acetoxyethyl sulfone moiety, saving the cost for waste water treatment by using a small amount of salt in salting-out process and furthermore obtaining bright color with high dyeing yield and substantivity.

  • PDF

해수간헐침투되는 철근콘크리트의 부식도 평가 (Corrosion Level of RC Concrete Specimen Intermittently Attacked by Sea Water)

  • 정철희;정영수;최응규;원종필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.207-212
    • /
    • 1996
  • Recently, massive concrete structures exposed to salt from ocean marine environments, or from winter deicing. The corrosion caused by chloride-penetration may affect severey the durability and service life of such a concretestructures. Thus, it is necessary to develop durable concrete to enhance the corrosion resistance. In this study, we investigate the usage of adequate corrosion-protection materials in order to reduce permability-coefficient of concrete and method of enhancing the durability of concrete structures using by penetrating corrosion-protection materials.

  • PDF

콘크리트 중의 철근부식 방지를 위한 외부전원법의 적용 (The Application of Impressed Current System for the Corrosion Control of Reinforcing Steel in Concrete)

  • 문한영;김성수;김홍삼
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.197-202
    • /
    • 1997
  • Recently the interest in the reinforcing steel corrosion due to the use of sea-sand and deicing salt, marine environment, and carbonation in RC structures is increasing, therefore the studies on the corrosion control of reinforcing steel in concrete are vigorously proceeding. In this study, from the viewpoint of electrochemical process of steel corrosion in concrete we applied the impressed current system among the cathodic protections to reinforcing steel in concrete and ascertained the protection effect by half-cell potential, corrosion rate, and depolarization.

  • PDF