• Title/Summary/Keyword: screws

Search Result 646, Processing Time 0.023 seconds

THE EFFECT OF LOCATION AND ANGLE OF DRILLING ON THE CHANGES OF THE DISTANCE BETWEEN TWO BLOCK SPECIMENS DURING SCREWING ON MINIPLATE FIXATION (소형금속판에 고정나사의 삽입시 drilling의 위치 및 각도에 따른 시편의 이동량에 대한 효과)

  • Oh, Hyun-Chul;An, Jin-Suk;Gu, Hong;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.213-221
    • /
    • 2006
  • Purpose This study was aimed to evaluate the effect of the location and angle of drilling on the changes of the distance between the two block specimens. Materials and methods In experimental group 1, the screw holes were prepared by drilling in the distal portion of compression part of the plate at $90^{\circ}$. In experimental group 2, the drilling was performed at an angle of $30^{\circ}$ proximal to the miniplate, and in experimental group 3, at $30^{\circ}$ distal respectively. In control group, the drilling was performed to the center of hole at $90^{\circ}$. The fixation screw length was 5 mm, 7 mm, and 9 mm in all groups. The results were as follows. Results 1. In control group, the mean changes between two specimens were 0.01 mm, 0.02 mm, and 0.00 mm in 5 mm, 7 mm, and 9 mm screws respectively. 2. In experimental group 1, the compression part was moved toward the retention part. The range of mean changes were from -0.39 mm to -0.43 mm. 3. In experimental group 2, the compression part was moved toward the retention part. The range of mean changes were from -0.51 mm to -0.56 mm. 4. In experimental group 3, the compression part was moved apart from the retention part and the range of mean changes were from 0.55 mm to 0.56 mm. 5. The changes were significantly different between all groups(p<0.01). Conclusion These results suggest that 0.4$\sim$0.5 mm of compressive effect can be achieved by drilling on the distal area of the screw hole at an angle of $90^{\circ}$ and by the proximal angulation to the miniplate, and the gap between specimens can be increased by distal angulation to the miniplate during drilling.

THE HISTOLOGIC STUDY OF BONE HEALING AFTER HORIZONTAL RIDGE AUGMENTATION USING AUTO BLOCK BONE GRAFT (자가골 블럭 이식을 이용한 수평골 증강술시 이식골의 치유)

  • Oh, Jae-Kwen;Choi, Byung-Jun;Lee, Baek-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.3
    • /
    • pp.207-215
    • /
    • 2009
  • Purpose: The aim of the present study is to evaluate the long term bone healing after horizontal ridge augmentation using auto block bone graft for implant installation timing. Materials and Methods: Five Beagle dogs(which were 14 months old and weighted approximately 10kg). In surgery 1(extraction & bone defect), premolars(P2, P3,P4) were extracted and the buccal bone plate was removed to create a horizontally defected ridge. After three months healing, in surgery 2(ridge augmentation). Auto block bone grafts from the mandibular ramus were used in filling the bone defects were fixed with stabilizing screws. The following fluorochrome labels were given intravenously to the beagle dogs: oxytetracycline 1week after the surgery, alizarin red 4 weeks after the surgery, calcein blue 8 weeks after the surgery. The tissue samples were obtained from the sacrificed dogs of 1, 4, 8, 12, 16 weeks after the surgery. Non-decalcified sections were prepared by resin embedding and microsection to find thickness of $10{\mu}m$ for the histologic examination and analysis. Results: 1. We could achieve the successful reconstruction of the horizontal bone defect by auto block bone graft. The grafted bone block remained stable morohologically after 16 weeks of the surgery. 2. In the histologic view. We observed osteoid tissue from the sample $4^{th}$ week sample and active capillary reconstruction in the grafted bone from the $12^{th}$ week sample. Healing procedures of auto bone grafts were compared to that of the host bone. 3. Bone mineralization could be detected from the $8^{th}$ week sample. 4. Fluorochrome labeling showed active bony changes and formation at the interface of the host bone and the block graft mainly. Bony activation in the grafted bone could be seen from the $4^{th}$ week samples. Conclusions: Active bone formation and remodeling between the grafted bone and host bone can be seen through the revascularization. After the perfect adhesion to host bone, Timing of successful implant installation can be detected through the ideal ridge formation by horizontal ridge augmentation.

Rapid canine retraction in a Class II bialveolar protrusion case using a lingually extended distraction screw (제II급 치조 전돌 환자에서 설측 견인 장치를 이용한 급속 견치 견인술)

  • Ahn, Kwang-Seok;Joo, Euk;Park, Ju-Young;Ryu, Young-Kyu;Cha, In-Ho;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.308-320
    • /
    • 2006
  • Rapid canine retraction, first introduced by Liou, is a distraction osteogenesis applied to the periodontal ligament tissue. Rapid tooth movement was facilitated by establishing minimal bony resistance on the distal surface of the canine by socket preparation and by osteogenesis on the mesial side in response to the periodontal distraction. Since undesired buccal tipping or extrusion of the canine during retraction tends to occur, it is crucial to maintain the firm path of movement and the axis of the canine during retraction. In order to improve the predictability of the canine movement, lingually extended distraction screws with heavy labial guiding wires were designed. Prefabricated plastic canine models for the estimation of socket depth and miniscrew implants for anchorage reinforcement were also devised. Applying these devices to a female patient with Class II anterior protrusion, the whole treatment was effectively finished in 13 months. Loss of vitality or periodontal problems did not occur throughout treatment, and stable occlusion was maintained during 10 months of retention. This case report demonstrates that a predictable rapid canine retraction can be achieved through the use of this modified technique.

Microwave Breakdown and High-Power Handling Capability of Circular Waveguide Cavity Filter (원통형 도파관 캐비티 필터의 마이크로파 방전과 고전력 취급 능력)

  • Lee, Sun-Ik;Kim, Joong-Pyo;Lim, Won-Gyu;Kim, Sang-Goo;Jang, Jin-Baek
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.3
    • /
    • pp.80-85
    • /
    • 2017
  • In this paper, a mircrowave breakdown of X-band circular waveguide cavity filter, which occurred during ground test, was introduced, and electro-magnetic field simulation results to identify a root cause, and the analysis of possibility of its occurrence on orbit operation were presented. Filter modeling for simulation was conducted with a commercial tool (FEST3D), and electric fields inside the filter were monitored at the input of 1 W continuous wave. In our observation, strong electric field intensities were monitored on the tuning screws especially at the input of band-edge frequencies. The threshold power levels for the breakdown were also estimated and compared with the input power levels actually injected to the filter. From this estimation, we could figure out that the power exceeding the breakdown threshold was injected to the filter so that strong electric fields were generated and temperature increased high, and this became a root cause of the electrical short. Our further analysis showed that this kind of microwave breakdown is not likely to occur on orbit operation, and multipactor is expected not to occur at the input of band-edge frequencies. As a measure to prevent the microwave breakdown, we suggested to avoid the injection of band-edge frequencies and inject lower power levels to the filter.

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.

Facial Nerve Palsy after Bilateral Sagittal Split Ramus Osteotomy: Case Report (양측 하악지 시상골 절단술 후 발생한 안면 신경 마비의 증례)

  • Jin, Soo-Young;Kim, Su-Gwan;Kim, Hak-Kyun;Moon, Seong-Yong;Oh, Ji-Su;Jeong, Kyung-In;Jeon, Woo-Jin;Yun, Dae-Woong;Yang, Seok-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.3
    • /
    • pp.276-280
    • /
    • 2011
  • BSSRO (bilateral sagittal split ramus osteotomy) is an effective surgical method for maxillofacial deformities. Rigid fixation using a plate and screws can stabilize bony segments and induce early mouth opening. Though this procedure has a low complication rate, normal function and esthetic recovery is achieved through proper and early management of the complications. Complications consisting of temporomandibular disorders, sensory disturbances due to inferior alveolar nerve damage, open bite, malunion or nonunion, and facial nerve palsy occur, but these rarely develop. Facial nerve palsy causes the muscles involved in facial expression to depress, which results in ocular dryness or retinal damage. When facial nerve palsy develops, early management involving steroid medication and physical therapy is effective. In the case of severe damage, surgical intervention should be considered. A 20-year-male patient came to the oral and maxillofacial surgery department for orthognathic surgery. The mandible was set back by BSSRO under general anesthesia. Facial nerve palsy was observed on the left side of the face: steroid and vitamins were administered early and physical therapy was performed daily. These forms of management can aid in function and allow for gradual esthetic recovery. Presumed causes were excessive soft tissue retraction or soft tissue injury by the osteotome at the horizontal osteotomy of the ramus. Careful dissection, retraction and a precise osteotomy are needed for protection of the facial nerve. If nerve damage is observed, early management can help in the recovery of facial nerve function and esthetics.

Comparison of Posterior Fixation Technique and Anterior-Posterior Fixation Technique in Subtalar Arthrodesis (거골하 유합술 시 전방 및 후방 관절면 고정술식과 후방 관절면 단독 고정술식의 비교)

  • Jung, Hong-Geun;Cho, Hyeoung-Woen;Park, Hyun-Woo;Park, Jong-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.116-122
    • /
    • 2012
  • Purpose: Subtalar arthrodesis has been the gold standard for the painful subtalar joint disorders. Successful subtalar arthrodesis requires fusion of the 3 facet joints. The purpose of the study is to compare the clinical outcome of the posterior fixation (P2) and anterior-posterior (A1P1) fixation technique for subtalar arthrodesis which enhance anterior and middle facet fixation. Materials and Methods: The study is based on the 20 feet (19 patients) of the subtalar arthrodesis utilizing cannulated screws from September 2006 to September 2009 with at least 1-year follow-up. Two fixation techniques were utilized for the subtalar arthrodesis: 1) posterior fixation only (P2, 7 feet, 35%) and 2) anterior-posterior (A1P1) fixation method (13 feet, 65%). Visual Analog Scale Pain (VAS) score, American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score (maximum: 94 points), the time for returning to daily living and the patient satisfaction were also evaluated. Results: Average follow-up period were 13.2 months (12-3 mo). The AOFAS score improved from preoperative average 45 (0-68) to 81.6 (62-94), while VAS score was decreased from average 8.0 (3-10) to 1.8 (0-5) at final follow-up. Ninety-five percent of the patients were satisfied with surgery. All the patients returned to daily living at average 7.2 months (2-15 mo) post-surgery. Radiographically, 2 techniques both showed 100% fusion of the posterior compartment of the subtalar joint. Postoperative complications were 1 case of low grade infection and 1 case of sural nerve neuralgia. Conclusion: The subtalar arthrodesis using A1P1 fixation technique showed better fusion rate of the anterior compartment of the subtalar joint compared to P2 fixation technique although the 2 techniques both showed similar favorable clinical outcome. Therefore the A1P1 fixation technique is found to be a viable option to address chronic painful subtalar joint disorders to enhance the anterior compartment fixation.

A STUDY ON THE TORQUE VALUES IN THE DIFFERENT IMPLANT SYSTEM (수종 임플랜트 시스템에서의 회전력에 관한 연구)

  • Moon, Ick-Hun;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.335-353
    • /
    • 1995
  • The purpose of this study was to the determine the optimal torques values to tighten the retaining screw. 3-different implant system tested were as follows : Branemark implant system$(3.75mmD{\times}100mm)$, Steri-Oss implant system$(3.8mmD{\times}10mm)$. One fixtures of each implant system was mounted into the epoxy resin block and abutment/superstructure complex was constructed. Eighty dental college students(male : 40, female : 40) of Chosun University were selected and were asked to tighten the retaining screws. Abutment/superstructure complex of each implant system was tightened to the maximum torque by use of hand-held screw driver, and then torque value was measured with torque value was measured with torque driver(Tohnichi torque driver, model 20 FTD, Tohnichi MFG, Co., LTD., Tokyo, Japan). Abutment/superstructure complex of each implant system was titghtened to each torque of 10 N-cm, 20 N-cm and 30 N-cm, and then the dynamic load(vertical & diagonal load) was applied to the abutment / superstructure complex. The gap between abutment/superstrure in each implant system was measured with 3-dimensional measuring microscope(model No. 850, Germany). The results were as follow : 1. Torque values according to the individual subjects showed wide range. 2. Torque values according to sex showed statistical significant difference. Those are as follows : in case of male, $9.38{\pm}2.93$ N-cm ; incase of female, $7.80{\pm}2.25$ N-cm. 3. Torque values according t implant systems showed statistical significant difference. Those are as follows : in ase of Branemark implant system, $6.54{\pm}1.54$ N-cm : in ase of Steri-Oss implant system, $10.1{\pm}2.88$ N-cm ; in case of IMZ implant system, $9.18{\pm}2.17$ N-cm. 4. The more torque value of tightening screw was increased, the less the gap was after the vertical and diagonal loading. 5. The gap after the diagonal loading was greater than that after the vertical loading. 6. The magnitude of gap between abutment/superstructure in order of IMZ, Steri-Oss, Branemark implant system after the verical and diagonal loading. 7. The gap under the diagonal loading after applying 30 N-cm torque showed no statistical significant difference in cases of the Branemark system and the Steri-Oss implant system but it showed significant different in case of the IMZ implant system.

  • PDF

Removal torque of a two-piece zirconia abutment with a novel titanium component in an internal connection implant system after dynamic cyclic loading (새로운 타이타늄 구성요소를 사용한 내부연결 임플란트용 지르코니아 지대주의 동적하중 후 나사 제거력)

  • Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.2
    • /
    • pp.151-155
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate screw removal torque of the two-piece zirconia abutment with the novel titanium component compared to the conventional one-piece titanium abutment in the internal connection implant before and after dynamic cyclic loading. Materials and methods: Two types of the abutment assemblies with internal connection were prepared and divided into the groups; titanium abutment-titanium abutment screw assemblies as control, and zirconia abutment-titanium socket-titanium abutment screw assemblies as experimental group. A total of 12 abutments and implants were used of six assemblies each group. Each assembly was tightened to 30 Ncm. A cyclic load of 300 N at an angle of 30 degrees in reference to the loading axis was applied until one million cycles or failure. The removal torque values (RTVs) of the abutment screws were measured with a digital torque gauge before and after cyclic loading. The RTVs of the pre load and post load were analyzed with t-test, and P-values < .05 were considered statistically significant. Results: The assemblies of both groups survived all after the dynamic cyclic loading test without screw loosening. The statistically significant differences were found between the mean RTVs before and after the cyclic loading in both groups (P < .05). The RTV differences for the control and the experimental group were $-7.25{\pm}1.50Ncm$ and $-7.33{\pm}0.93Ncm$, respectively. Statistical analysis revealed that the RTV differences in both groups were not significantly different from each other (P > .05). Conclusion: Within the limitation of this study, the two-piece zirconia abutment with the titanium component did not show a significant RTV difference of the abutment screw compared to the titanium abutment after dynamic cyclic loading.

The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study (내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구)

  • Kyung, Kyu-Young;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.114-118
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the effects of a titanium component for the zirconia abutment in the internal connection implant system on screw loosening under thermocycling conditions. Materials and Methods: Internal connection titanium abutments and external connection zirconia abutments with titanium sockets were connected respectively to screw-shaped internal connection type titanium implants with 30 Ncm tightening. These implant-screw-abutment assemblies were divided into two groups of five specimens each; titanium abutments as control and zirconia abutments with titanium sockets as experimental group. The specimens were subjected to 2,000 thermocycles in water baths at $5^{\circ}C$ and $55^{\circ}C$, with 60 seconds of immersion at each temperature. The removal torque values (RTVs) of the abutment screws of the specimen were measured before and after thermocycling. RTVs pre- and post-thermocycling were investigated in statistics. Results: There was not screw loosening identified by tactile and visual inspection in any of the specimens during or after thermocycling. The mean RTV difference for the control group and the experimental group were $-1.34{\pm}2.53Ncm$ and $-1.26{\pm}2.06Ncm$, respectively. Statistical analysis using an independent t-test revealed that no significant differences were found in the mean RTV difference of the groups (P > 0.05). Conclusion: Within the limitations of this in vitro study, the titanium socket for the zirconia abutment did not show a significant effect on screw loosening under thermal stress compared to the titanium abutment in the internal connection implant.