• 제목/요약/키워드: screw diameter

검색결과 190건 처리시간 0.03초

Pedicle Morphometry for Thoracic Screw Fixation in Ethnic Koreans : Radiological Assessment Using Computed Tomographic Myelography

  • Choi, Yang-Soo;Kim, Young-Jin;Yi, Hyeong-Joong;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.317-321
    • /
    • 2009
  • Objective : In the thoracic spine, insertion of a pedicle screw is annoying due to small pedicle size and wide morphological variation between different levels of the spine and between individuals. The aim of our study was to analyze radiologic parameters of the pedicle morphometry from T1 to T8 using computed tomographic myelography (CTM) in Korean population. Methods : For evaluation of the thoracic pedicle morphometry, the authors prospectively analyzed a consecutive series of 26 patients with stable thoracic spines. With the consent of patients, thoracic CTM were performed, from T1 to T8. We calculated the transverse outer diameters and the transverse angles of the pedicle, distance from the cord to the inner cortical wall of the pedicle, and distance from the cord to the dura. Results : Transverse outer pedicle diameter was widest at T1 ($7.66{\pm}2.14\;mm$) and narrowest at T4 ($4.38{\pm}1.55\;mm$). Transverse pedicle angle was widest at T1 ($30.2{\pm}12.0^{\circ}$ and it became less than $9.0^{\circ}$ below T6 level. Theoretical safety zone of the medial perforation of the pedicle screw, namely, distance from the cord to inner cortical wall of the pedicle was more than 4.5 mm. Conclusion : Based on this study, we suggest that the current pedicle screw system is not always suitable for Korean patients. Computed tomography is required before performing a transpedicular screw fixation at the thoracic levels.

목재(木材)파티클과 철강결체(鐵鋼結締)가 보오드의 물리적(物理的) 성질(性質)에 미치는 영향(影響) (Effect of Combining Wood Particles and Wire Net on the Physical Properties of Board)

  • 이필우
    • Journal of the Korean Wood Science and Technology
    • /
    • 제13권3호
    • /
    • pp.3-26
    • /
    • 1985
  • The object of this study was to investigate the effects on physical and mechanical properties of wood particle and sawdust board combined with wire net. Conventional forming, press-lam, and veneer comply boards combining one to four wire net sheets were made from wood particle and sawdust with different spacings (8, 10, 12, and 18 Mok) and different wire diameters (0.35, 0.50, and 0.80mm) composing wire net. They were compared and analyzed statistically with specific gravity, thickness swelling, length swelling, bending properties (modulus of rupture, modulus of elasticity, work to proportional limit, and total work), internal bonding strength, and screw holding strength between wood particle and sawdust boards. The results obtained at this study as cording to the discussions might be concluded as follows; 1. In specific gravity, both particle and sawdust boards by press-lam method were higher than by conventional forming and veneer comply method, and the boards containing more wire net sheets also showed higher value. But the wire net spacings(Mok) had no influence on specific gravity. In general, particle board showed higher specific gravity than sawdust board. Veneer comply board showed lowest specific gravity values. 2. Both particle and sawdust boards by press-lam method was slightly lower than by conventional forming and veneer comply method in thickness swelling. The sawdust board containing 8, 12. and 18 Mok wire net showed lower thickness swelling than the corresponding particle board, but both sawdust and particle boards containing the T8 and 10 Mok wire net showed higher and similar thickness swelling. 3. Both particle and sawdust boards containing wire net showed no difference in MOR and MOE of bending. Comply board was the highest and particle board showed slightly higher than sawdust board in MOR and MOE values. 4. In work to proportional limit and total work in bending, both particle and sawdust boards containing thicker wire diameter and more wire net sheets showed higher value. From these facts, it is conceivable that boards with thicker wire diameter and more wire net sheets show increasing resistance against external force. But there was no significant difference between particle and sawdust borads. 5. In resistance against delamination (internal bonding strength), both sawdust and particle boards containing wire net showed lower value than control, and also showed decreasing tendency with more number of wire net sheet composed. Particle board showed higher resistance against delamination than sawdust board. 6. In screw holding strength, sawdust board containing thicker wire diameter and more wire net sheets showed higher value, but particle board by press-lam method was higher than by conventional forming and veneer comply method. Screw holding strength of particle board was higher than that of sawdust board.

  • PDF

가변성 폐동맥 혈류조절기의 실험적 연구 (An Experimental Study of Percutaneously Adjustable Pulmonary Artery Banding Device)

  • 강경훈;김상현
    • Journal of Chest Surgery
    • /
    • 제30권6호
    • /
    • pp.580-584
    • /
    • 1997
  • 기존의 폐동맥 혈류 조절술(pulmonary래eV banding procedure)의 미비 점을 보완하여 피하에서 조절 가능한 폐동맥 혈류 조절기(pulmonary artery banding device)를 개발하였다. 조절기는 탄성력을 가진 스테인레스 철 사를 이용하여 지그재그형으로 형태를 만든 조절부,폴리비닐 카테터로 된 몸체 부위 및 볼트와 너트로 이 루어진 나사부로 구성되어 있다. 15∼20 kg의 네 마리 황견을 이용해 좌측 개흉술 후 하행 대동맥에 본 장 치를 장착한 후 때월 후 장치의 조절에 따르는 혈압의 변화에 대한 검사를 하였다. 검사 후 실험동물을 희생시켜 장치를 포항한 대동맥의 병리 조직 검사를 시행하였다. 조절기의 나사부를 회전시키므로서 혈관 에 장착된 조절기의 직경과 원주가 정확하고 용이하게 조절되었다. 조절기의 조절에 따라 측정한 혈압 변 화에서 혈압이 조절기의 회전수에 선형 증감을 나타냈다. 폐동맥 혈류 조절기의 장착이 용이하고 쉽게 조 절 가능하므로 이를 장차 임상에 적용시켜 보다 향상되길 기대한다.

  • PDF

교정용 미니스크류의 디자인과 피질골의 두께에 따른 역학적 안정성 평가 (MINISCREW STABILITY REGARDING DESIGN OF MINISCREW AND THICKNESS OF CORTICAL BONE)

  • 권영선;현홍근;김영재;김정욱
    • 대한소아치과학회지
    • /
    • 제38권3호
    • /
    • pp.250-259
    • /
    • 2011
  • 본 연구의 목적은 소아 청소년의 얇은 피질골에서 안정성을 가지는 미니스크류 디자인을 제시하고자 하는 것이다. 직경, 길이, 몸체모양을 달리한 교정용 미니스크류를 피질골의 두께를 달리한 두 종류의 인조골 시편에 식립하여 최대 식립 토크, 최대 제거 토크 및 측방 변위 토크를 측정하였다. 연구결과 피질골의 두께 및 미니스크류의 직경, 길이, 몸체모양은 모두 최대 식립 토크, 최대 제거 토크, 측방 변위 토크에 유의한 영향을 미쳤다. 피질골의 두께가 가장 중요한 요소로 나타났으며 원추형이 원통형보다 초기 고정력이 우수하고, 직경이 증가할수록 역학적 고정력 확보에 유리하였다. 길이의 증가는 다른 요소에 비해 초기 고정력 확보에 미치는 영향이 크지 않으나 6 mm와 8 mm는 고정력 확보에 통계적으로 유의한 차이가 있었다(p<0.05). 피질골이 얇은 소아 청소년의 골에서 미니스크류의 안정성은 원추형, 직경 1.8 mm가 유리하며, 길이도 6 mm 보다는 8 mm가 유리하다.

A Computed Tomography-Based Anatomic Comparison of Three Different Types of C7 Posterior Fixation Techniques : Pedicle, Intralaminar, and Lateral Mass Screws

  • Jang, Woo-Young;Kim, Il-Sup;Lee, Ho-Jin;Sung, Jae-Hoon;Lee, Sang-Won;Hong, Jae-Taek
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권3호
    • /
    • pp.166-172
    • /
    • 2011
  • Objective : The intralaminar screw (ILS) fixation technique offers an alternative to pedicle screw (PS) and lateral mass screw (LMS) fixation in the C7 spine. Although cadaveric studies have described the anatomy of the pedicles, laminae, and lateral masses at C7, 3-dimensional computed tomography (CT) imaging is the modality of choice for pre-surgical planning. In this study, the goal was to determine the anatomical parameter and optimal screw trajectory for ILS placement at C7, and to compare this information to PS and LMS placement in the C7 spine as determined by CT evaluation. Methods : A total of 120 patients (60 men and 60 women) with an average age of $51.7{\pm}13.6$ years were selected by retrospective review of a trauma registry database over a 2-year period. Patients were included in the study if they were older than 15 years of age, had standardized axial bone-window CT imaging at C7, and had no evidence of spinal trauma. For each lamina and pedicle, width (outer cortical and inner cancellous), maximal screw length, and optimal screw trajectory were measured, and the maximal screw length of the lateral mass were measured using m-view 5.4 software. Statistical analysis was performed using Student's t-test. Results : At C7, the maximal PS length was significantly greater than the ILS and LMS length (PS, $33.9{\pm}3.1$ mm; ILS, $30.8{\pm}3.1$ mm; LMS, $10.6{\pm}1.3$; p<0.01). When the outer cortical and inner cancellous width was compared between the pedicle and lamina, the mean pedicle outer cortical width at C7 was wider than the lamina by an average of 0.6 mm (pedicle, $6.8{\pm}1.2$ mm; lamina, $6.2{\pm}1.2$ mm; p<0.01). At C7, 95.8% of the laminae measured accepted a 4.0-mm screw with a 1.0 mm of clearance, compared with 99.2% of pedicle. Of the laminae measured, 99.2% accepted a 3.5-mm screw with a 1.0 mm clearance, compared with 100% of the pedicle. When the outer cortical and inner cancellous height was compared between pedicle and lamina, the mean lamina outer cortical height at C7 was wider than the pedicle by an average of 9.9 mm (lamina, $18.6{\pm}2.0$ mm; pedicle, $8.7{\pm}1.3$ mm; p<0.01). The ideal screw trajectory at C7 was also measured ($47.8{\pm}4.8^{\circ}$ for ILS and $35.1{\pm}8.1^{\circ}$ for PS). Conclusion : Although pedicle screw fixation is the most ideal instrumentation method for C7 fixation with respect to length and cortical diameter, anatomical aspect of C7 lamina is affordable to place screw. Therefore, the C7 intralaminar screw could be an alternative fixation technique with few anatomic limitations in the cases when C7 pedicle screw fixation is not favorable. However, anatomical variations in the length and width must be considered when placing an intralaminar or pedicle screw at C7.

국내산 리기다소나무를 이용한 목재 모형 사방댐의 강도 성능 평가 I (Strength Properties of Wooden Model Erosion Control Dams Using Domestic Pinus rigida Miller I)

  • 김상우;박준철;이동흡;손동원;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권6호
    • /
    • pp.77-87
    • /
    • 2008
  • 국내산 주요 침엽수 소경목의 활용 방안으로 리기다소나무를 이용한 목재 모형 사방댐을 제작하여 강도 성능을 평가하였다. 목재 모형 사방댐은 직경 90 mm의 CUAZ-2 (Copper Azole) 처리한 리기다소나무 방부 원주목을 사용하여 3 Type으로 접합부를 달리하여 제작하였다. 각 Type별 사방댐은 횡목 5층 종목 4층 총 9층의 높이 790 mm로 제작 하였으며 수평 재하 시험과 충격 시험을 통한 강도 성능 평가와 화상처리를 통한 구조물의 변형을 검토 하였다. 직경 90 mm의 원주목을 사용한 목재 모형 사방댐의 수평 재하 시험 결과 직결나사를 사용한 경우 쇄석의 유무는 강도에 큰 영향을 미치지 않았지만 변형은 23% 감소하였다. 전선볼트를 사용한 일체형 사방댐의 경우 쇄석을 채운 경우 1.5배 강도가 증가하고 변형은 감소하였다. 직결나사에 고리가 달린 전선볼트로 보강한 경우 4.8배 강도가 증가하였다. 직경 90 mm 목재 모형 사방댐의 충격 시험 결과 쇄석을 채우지 않은 직결나사 사방댐은 1회 충격에 구조물 전체가 파괴되었으며 전선볼트를 사용한 사방댐은 1회 충격시 779 kgf의 충격이 직접적으로 가해지는 횡목에서 파괴되었다. 2회 충격시 기초부가 파괴되며 545 kgf로 반력이 감소하였고 3회 충격시 기초부 전체가 파괴되며 263 kgf로 반력이 감소하였다.

콤비네이션 임프란트 크라운(Combination Implant Crown)을 이용한 단일치아의 임프란트 보철수복증례 (SINGLE TOOTH IMPLANT RESTORATION USING COMBINATION IMPLANT CROWN : A CASE REPORT)

  • 김래경;송언희;최병갑;김현철;안현정
    • 대한치과보철학회지
    • /
    • 제37권3호
    • /
    • pp.375-382
    • /
    • 1999
  • The purpose of this article is to present the clinical and laboratory procedures for single tooth restoration using 'Combination Implant Crown'. It is cemented on implant abutment and that abutment is screw-retained over implant body. This type of implant restorations has the advantages of cement-retained restoration while being antirotational and retrievable. And, more esthetic and functional result can be achieved by minimizing the size of access hole. The results were as follows : 1. Preparation of abutment below the cuff line should be avoided 2. Axial reduction of implant abutment should not be excessive because it may weaken the abutment 3. More esthetical and functional occlusal surface was achieved with a minimal access hole which is slightly larger than the diameter of hex driver to enable future total retrievability. 4. Combination Implant Crown has the advantages of both the cement-retained and screw-retained type implant restoration. 5. Cementation between implant crown and abutment reduces screw loosening through even force distribution

  • PDF

임플란트 나사의 안정성 (Stability of implant screw joint)

  • 정재헌;곽종하;장두익
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.125-137
    • /
    • 2003
  • The use of screw-retaind prosthesis on an osseointegrated implant is a popular treatment modality offering relative ease in the removal of the restoration. One of the complications associated with this modality is the loosening of the abutment and coping screws. Loosening of the screws results in patient dissatisfaction, frustration to the dentist and, if left untreated, component fracture. There are several factors which contribute to the loosening of implant components which can be controlled by the restorative dentist and lab technician. This article offers pratical solutions to minimize this clinical problem and describes the factors involved in maintaining a stable screw joint assembly. To avoid joint failure, adherence to specific clinical, as well as mechanical, parameters is critical. With respect to hardware, optimal tolerance and fit, minimal rotational play, best physical properties, a predictable interface, and optimal torque application are mandatory. In the clinical arena, optimal implant distribution; load in line with implant axis; optimal number, diameter, and length of implants; elimination of cantilevers; optimal prosthesis fit; and occlusal load control are equally important.

Crystal growth and characteristics of lysozyme crystals

  • Kojima, Kenichi
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.3-3
    • /
    • 2002
  • Many studies on crystal growth mechanisms of the hen egg-white lysozyme protein crystals have mainly performed by optical microscopy and atomic force microscopy (AFM). As results, two types of growth mechanisms, which are a two-dimensional nucleation mechanism and a spiral growth mechanism, were identified. However, there was no direct evidence of grown-in screw dislocations at the spiral sites. We first observed the screw dislocations in tetragonal lysozyme crystals using synchrotron X-ray topography. In addition, to confirm the characteristics of dislocations, we have observed some elastic constants in lysozyme crystals in terms of the sound velocity measurement by pulse echo methods. Tetragonal hen egg-white lysozyme crystals were grown by the concentration gradient method. The crystals were grown in test tubes, with an inner diameter of 8 ㎜ and 80 ㎜ in length, held vertically. The test tubes were kept at 23C for 2 weeks. The maximum size of crystals were 3×3×4 ㎟. The high quality crystals were examined by Laue topography with a water filter using synchrotron radiation. Figure is a X-ray topograph. Several straight screw dislocations were observed. We also determined Burgers vector to be a [110] direction. The measurement of sound velocity was performed by the digital signal processing method. the crystals were placed in stainless steel vessel, which was filled with lysozyme solution used for crystal growth. We observed the longitudinal sound velocity along the [110] direction in the tetragonal is obtained to be 1817 ㎧. Therefore, Young modulus and shear modulus were evaluated to be 2.70 Gpa and 1.02 Gpa, respectively, if we assumed Poisson ratio is 0.33. These results will be discussed at the meeting.

  • PDF

A Novel Axial Foldable Mechanism for a Segmented Primary Mirror of Space Telescope

  • Thesiya, Dignesh;Srinivas, Arra;Shukla, Piyush
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권3호
    • /
    • pp.269-279
    • /
    • 2015
  • Future space missions will have larger telescopes in order to look deeper into space while improvising on spatial resolution. The primary mirrors for these telescopes will be so large that using a monolithic mirror will be nearly impossible because of the difficulties associated with its fabrication, transportation, and installation on a launch vehicle. The feasibility of launching these huge mirrors is limited because of their small launch fairing diameter. The aerodynamic shape of the fairing requires a small diameter, but the height of the launch vehicle, which is available for designers to utilize, is larger than the fairing diameter. This paper presents the development of an axial deployment mechanism based on the screw jack principle. The mechanism was designed and developed, and a prototype was constructed in order to demonstrate a lab model.