편면 증감지 -필름계의 성능실험 (An Experiment on Single Screen-Film System)

  • 강홍석;박준철;신화수;이인자;허준;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.55-59
    • /
    • 1987
  • Single screen-film systems have been used to soft tissue radiography, especially to mammo-graphy, for the Purpose of reducing patient dose, Recently, by the development of rare earth screens, they are being used to general radiography including stomach radiography. Single screen-film systems have lower speeds, but higher resolutions than double screen-film systems. And so, they can produce high image quality in oblique radiography and tomography. Authors have tested basic and physical characteristics of sigle screen-film systems, and applied them in clinical fields. Hereupon, we evaluate the sin91e rare earth screen-film systems very practicable, because they have higher speeds and higher image quality than double screen-film systems.

  • PDF

일반(一般)X선촬영(線撮影)에 있어서 편면(片面)시스템의 응용(應用) (An Application of Single Screen-Film System on General Radiography)

  • 박명환;조준석;송재관;허준;유장수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제13권2호
    • /
    • pp.15-20
    • /
    • 1990
  • In clinical fields, single screen-film system will be generalized according to high speed and high image qualify of intensifying screen film system in future. In single screen-film system, for imaging the best image, we must choice good film according to speed and gredient. Double screen-film system will be replaced single screen film system in general radiography. Author has thought that single screen film system will be developed new diagnosis area according to X-Ray films.

  • PDF

X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가 (A comparative study for resolution and density of chest imaging using film/screen, CR and DR)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제4권1호
    • /
    • pp.25-30
    • /
    • 2010
  • 이 연구 목적은 흉부영상의 진단에 적절한 해상력과 음영에 대한 적절한 평가를 위해서다. 해상력을 비교하기 위해서, linear 해상력 팬텀을 사용하여 film/screen(선생님이 원하시는 conventional radiography : film/screen), CR, DR, 촬영했다. 해상력을 비교하기 위해 2명의 영상의학과 전문의와 3명의 방사선사가 블라인드 테스트를 통하여 평가했다. DR 은 3.95 필름/ 스크린은 3.58, CR은 3.48의 평가가 나왔다. 음영에 대해 분석은, CR, DR의 film/screen의 정상적인 흉부영상 50장을 선택했다. 이 흉부영상에서 7부위(폐야, 폐야 윤곽, 종격동 I, 종격동 II, 심장 음영 I, 심장음영 II, 횡격막)을 정하여 덴시토미터(농도계)을 사용하여 음영을 평가했다. 우리의 분석 방법은 낮은 영상(음영)을 0에서부터 가장 우수한 영상(음영) 2를 정한 일본의 흉부 x-ray 평가 방법을 적용했다. DR의 경우 종격동 1, 종격동2, 심장 1, 심장2, 횡격막에서 2점을 기록하여 우수했다. 이와 반대로 CR에서는 폐부위와 폐음영 부위에서 2점으로 우수했다. 결론적으로, 해상력과 음영에 비교하면 후처리 알고리즘과 작은 픽셀 사이즈에 의한 DR은 CR과 film/screen 보다 우수하다고 도출하였다.

ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구 (A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom)

  • 홍동희;정홍량;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.241-247
    • /
    • 2006
  • 최근 유방 영상 검사는 의료영상저장전송시스템(Picture Archiving and Communication System, PACS)의 도입과 특수의료장비에 관한 정도관리 실시로 인해 Computed Radiography(CR)과 Digital Radiography(DR)에 관한 관심도와 이용도가 증가하고 있는 추세이다. 본 연구는 유방영상검사에 이용되고 있는 각 시스템별 검출기의 영상 화질을 정도관리 시 사용되는 ACR 팬텀을 이용하여 비교 분석하였다. 평가 방법은 심리적인 방법으로 ACR 팬텀을 이용한 영상의 수치 값을 SPSS 통계프로그램을 이용하여 유의성과 신뢰도를 분석한 결과는 다음과 같다. 1. Fiber에서는 Screen-Film인 경우 3.9점, CR($50\;{\mu}m$)인 경우 4.2점, CR($100\;{\mu}m$)인 경우 3.2점, DR인 경우 4.2점을 얻어 CR($50\;{\mu}m$), DR, Screen-Film, CR($100\;{\mu}m$)순으로 높은 점수를 받았다(P<0.05). 2. Calcification은 Screen-Film인 경우 2.7점, CR($50\;{\mu}m$)인 경우 2.5점, CR($100\;{\mu}m$)인 경우 2.0점, DR인 경우 2.9점을 얻어 DR, Screen-Film, CR($50\;{\mu}m$), CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(0.025(P<0.05). 3. Mass는 Screen-Film인 경우 3.8점, CR($50\;{\mu}m$)인 경우 3.8점, CR($100\;{\mu}m$)인 경우 3.6점, DR인 경우 4.5점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다(P<0.1). 4. 합계점수 평가는 Screen-Film인 경우 10.4점, CR($50\;{\mu}m$)인 경우 10.6점, CR($100\;{\mu}m$)인 경우 8.7점, DR인 경우 11.3점을 얻어 DR, CR($50\;{\mu}m$), Screen-Film, CR($100\;{\mu}m$) 순으로 높은 점수를 받았다. 이상의 결과는 DR, Screen-Film시스템이 CR($100\;{\mu}m$)에 비해 화질이 우수하다는 것을 알 수 있다. 하지만 DR은 소자에 의한 불안정성, Screen-Film은 artifact에 의한 화질 저하 등 단점을 가지고 있으며, 화질 저하가 문제였던 CR시스템 중 Dual-Side방식의 CR($50\;{\mu}m$)을 사용한 경우에는 Screen-Film 시스템과 차이가 없는 것으로 나타났다. 향후 방사선 영상검사가 디지털화 되는 추세이므로 유방영상검사도 각 시스템의 발전과 보완이 필요할 것으로 사료된다.

  • PDF

비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가 (Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems)

  • 윤제웅;이형구;서태석;최보영;신경섭;문인기;김홍권;한용우;남승배
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.161-170
    • /
    • 1999
  • 비정질 실리콘 방사선 촬영기와 기존 X-ray filmrh과의 영상질 비교를 통하여 시스템의 성능을 평가하였다. 다양한 영상질 평가를 위하여 MTF (Modulation Transfer Function), NPS (Noise Power Spectrum), Contrast를 측정하여 계산하였다. 실험 결과 DR의 MTF는 기존 film-screen system과 유사하였다. Noise 특성은 두 시스템 모두 quantum noise가 주를 이뤘으며, 특히 DR 에서는 전기적인 noise가 발견되었다. 또한 우수한 sensitivity 특성과 영상처리를 통하여 DR 시스템이 기존의 film-screen 시스템보다 놀은 대조도를 보였다. 이와 같이 DR에서는 기존 film-screen 시스템과 유사한 해상도와 영상처리를 통해 같은 촬영조건에서도 향상된 대조도의 영상을 얻을 수 있었다. 본 연구를 통하여 의학적 활용과 관련된DR 시스템의성능에 대한 유용한 정보를 제공할 수 있으리라 기대한다.

  • PDF

흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究) (Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography)

  • 김정민;김동현;임태랑;석전유치;전전미향;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제15권1호
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

영상의학검사 일반촬영 분야의 촬영기법에 대한 분석 (National Data Analysis of General Radiography Projection Method in Medical Imaging)

  • 김정수;김정민;이영한;서덕남;최인석;남소라;윤용수;김현지;민혜림;허재;한성규
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.169-175
    • /
    • 2014
  • 2013년 국민건강보험심사평가원의 의료기관 데이터베이스에 따르면 1118개의 병.의원에 영상의학과가 개설되어있다. 이들 병원에는 CT, 투시촬영장치, 일반촬영장치와 같은 의료용 방사선 발생장치가 운영되고 있다. 이 중에서도 일반촬영장치는 가장 많은 병원에서 운영되고 있는 장비이다. 일반촬영장치의 경우 film-screen 장치에서 digital radiography 로 급격하게 변하고 있다. 하지만 그 촬영기법은 films-screen 기법을 그대로 사용하고 있어 디지털 장치의 맞는 촬영기법의 개발을 위한 전반적인 실태 조사가 필요하다. 이에 본 연구에서는 국내 의료기관의 일반촬영기법에 관한 조사를 시행하여 실제 병원에서 사용하고 있는 일반촬영기법의 기술적 항목에 대한 현황을 파악하여 보았다. 본 연구에서는 의료기관에서 일반적으로 사용되는 일반촬영기법 26개에 대한 촬영기법의 전국 단위 조사에서 흉부, 두부, 척추, 골반에 해당하는 검사에 대한 분석을 시행하였다.

Back Scatter Radiation이 CR영상(影像)에 미치는 영향(影響)

  • 이후민;김학성;조남수;고승일
    • 대한디지털의료영상학회논문지
    • /
    • 제2권1호
    • /
    • pp.92-95
    • /
    • 1996
  • Computed Radiography(CR) is a relatively new technology that relies on an image plate(IP) as an alternate x-ray sensor to screen/film. Standard CR cassettes do not have lead foil behind the IP to control scatter radiation. The result of this study indicate that such control is needed. In most screen/film cassettes, that lines the rear of the cassette eliminates back scatter radiation. This study was performed to Investigate on the effects of back scatter in CR images by size of exposure field, distance between the CR cassette and the wall of radiography room. 1. It showed artifacts from hinges and clips located on the back of CR cassette by back scatter radiation. 2. The greater effects of back scatter radiation in CR images was attributed to the greater size of exposure field and the longer distance between the CR cassette and the wall of radiography room.

  • PDF

개에서 복수의 평가에 있어서 필름-증감지 방사선 사진과 디지털 방사선 사진의 비교 (Comparison of Direct Digital Radiography and Conventional Film Screen Radiography for Detection of Peritoneal Fluid in Dogs)

  • 최호정;오이세;이기자;이영원
    • 한국임상수의학회지
    • /
    • 제29권1호
    • /
    • pp.18-22
    • /
    • 2012
  • 디지털 방사선 사진은 촬영 후 영상처리를 통해 대비도를 향상시킬 수 있다. 하지만 복강 내 대비도를 감소시키는 복수가 존재 할 경우, 디지털 방사선 촬영술의 장점이 어떻게 적용되는가에 대한 연구는 부족하다. 따라서 본 연구에서는 다양한 양의 액체를 복강 내 주입한 후, 필름-증감지 사진과 디지털 방사선 사진을 비교 판독하여 두 기법의 복수 검출 능력에 대해 평가하였다. 실험 결과 receiver operation curve를 이용한 평가에서 복수를 검출하는 데 디지털 방사선 촬영술과 필름-증감지 기법 간의 유의적인 차이가 없었지만 필름-증감지 기법이 디지털 방사선 촬영술보다 비교적 높은 정확도를 나타냈다. 곡선 아래 면적은 필름-증감지 기법이 디지털 방사선 촬영술보다 높은 값을 나타내었으며, 대부분의 주입 용량에서 필름-증감지 기법이 디지털 방사선 촬영술보다 더 높은 값의 곡선 아래 면적을 나타냈다. 이러한 결과는 복수의 검출에 있어서 필름-증감지 기법이 디지털 방사선 촬영술보다 다소 민감하다는 것을 의미한다. 이는 판독자가 최적의 영상을 찾는 과정에서 영상의 조절 기능을 통해 소량의 복수에 의해 복부 대비도가 감소된 것을 저평가하게 되는 경향 때문인 것으로 생각된다. 따라서 디지털 방사선 사진을 이용하여 복수를 평가하는 경우, 과도한 대비도 증가와 같은 촬영 후 조절 기능을 사용하는데 주의해야 하며, 초음파와 같은 다른 영상 진단 장비를 사용하여 복수를 확인하는 것을 추천한다.

비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구 (Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.163-171
    • /
    • 2003
  • 디지털 방사선 검출기의 성능을 측정하기 위해 변조전달할수(Modulation Transfer Function)을 측정하여 기존 방사선 영상 시스템인 필름/스크린과 비교하였다. 제작된 디지털 방사선 검출기는 TFT 패널위에 진공 증착법을 통해 비정질 셀레늄이 코팅되었다. 비교 측정물이 감도 400의 필름/스크린은 아날로그 방식의 방사선 검출기로서 현재 임상에서 이용되고 있는 필름이다. Square wave & slit 측정법을 통해 두 시스템의 변조전달함수를 측정하였다. 필름/스핀린의 반치폭(FWHM)은 357㎛(1.4 lp/mm at 50% spatial frequency)으로 측정되었으며, 디지털 방사선 검출 시스템은 200㎛(2.5 lp/mm at 50%)였다. 영상의 표현성능 평가의 결과 디지털 방사선 시스템은 필름 시스템보다 높은 것으로 나타났다.