• Title/Summary/Keyword: school zones

Search Result 483, Processing Time 0.026 seconds

Green Supply Chain Management in Vietnam Industrial Zone: Province-Level Evidence

  • Do, Anh Duc;NGUYEN, Quang Vinh;LE, Quoc Hoi;TA, Van Loi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.7
    • /
    • pp.403-412
    • /
    • 2020
  • The main purpose of this paper is to explore how green supply chain management (GSCM) and its evaluative factors have affected green supply chain management practice and performance in industrial zone. This study proposes a structural equation model of the relationships among four factors: internal awareness (IA); suppliers' pressure (SP); customers' awareness (CA); and regulations pressure (RP) and their effect on GSCM practice (PA) and GSCM performance (PE). We used a survey questionnaire to elicit perceptions/opinions about GSCM from three level of managers of 322 companies in Bac Ninh Province's industrial zones, Vietnam. PLS-SEM 3.0 software was applied to analyze and verify the gathered data, and the proposed hypothesis model. The results of path analysis show that internal awareness and customers' awareness are positively related to the GSCM practice and GSCM performance. However, suppliers' pressure and regulations pressure just impacted on GSCM practice. As a result, the testing of the relationship between GSCM practice and GSCM performance has been verified and supported. The findings of this study can help manager of companies in industrial zone understand the structure of GSCM, associate with the green supply chain management practice and green supply chain management performance, and be successful in green management organizations.

Hot Spots on Tc-99m MAA Perfusion Lung Scan (Tc-99m 거대응집알부민을 이용한 폐관류 스캔에서 관찰되는 다발성 열소)

  • Lim, Seok-Tae;Sohn, Myung-Hee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.288-290
    • /
    • 2001
  • A 61 year-old woman underwent perfusion and inhalation lung scan for the evaluation of pulmonary thromboembolism. Tc-99m MAA perfusion lung scan showed multiple round hot spots in both lung fields. Tc-99m DTPA aerosol inhalation lung scan and chest radiography taken at the same time showed normal findings (Fig. 1, 2). A repeated perfusion lung scan taken 24 hours later demonstrated no abnormalities (Fig. 3). Hot spots on perfusion lung scan can be caused by microsphere clumping due to faulty injection technique or by radioactive embolization from upper extremity thrombophlebitis after injection. Focal hot spots can signify zones of atelectasis, where the hot spots probably represent a failure of hypoxic vasoconstriction. Artifactual hot spots due to microsphere clumping usually appear to be round and in peripheral location, and the lesions due to a loss of hypoxic vasoconstriction usually appear to be hot uptakes having linear $borders^{1-3)}$. Although these artifactual hot spots have been well-known, we rarely encounter them. This report presents a case with artifactual hot spots due to microsphere clumping on Tc-99m MAA perfusion lung scan.

  • PDF

A Study of Fashion Sensibility and Consumer Sensibility of Men's Casual Brand's Patterned Woven Shirts (남성복 캐쥬얼 브랜드 무늬셔츠에 대한 패션감성과 소비감성 분석)

  • Lee, Seung-Hyun;Lee, Kyung-Hi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.3
    • /
    • pp.444-456
    • /
    • 2009
  • The purpose of this study is to understand consumer needs through Fashion Sensibilities and Consumer Sensibilities on Men's Casual Brand's Patterned Shirts. This study suggests the basis of planning effective design of Men's Casual Brand's Patterned Shirts by categorizing. The product from 2005 S/S to 2007 F/W is divided into the following sector: years, seasons, and product zones(adult, character, traditional), focusing on the design property of Men's Casual Brand's Patterned Shirts. An evaluation tool is composed of 19 pairs of image adjectives and 3 questionnaire as consumer need tool. Data were collected on March 3th to 31th in 2008 over Busan area. The data were sorted by using the SPSS statistics package program. Fashion sensibility of Men's Casual Brand's Patterned Shirts were expressed with 4 factors of attractivity, visibility, sensibility, hardness occupied 58.6% of the total. Therefore as attractivity, visibility, sensibility, hardness are important for product planning, it would be effective to consider these 4 factors before product planning.

Effects of Postural Stability using Electrical Stimulation on the Lower Limb (하지에 인가한 전기 자극이 자세안정성에 미치는 영향)

  • Lee, S.Y.;Yu, M.;Kim, D.W.;Kim, N.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.255-262
    • /
    • 2009
  • The present study analyzed the association between postural control and electrical stimulation by measuring body sway when use the electrical stimulations were applied to different stimulation zones in lower limbs. The subjects were 14 young adults and were, tested for two different visual condition: eyes open and eyes closed. The experiments were also performed in two different stance case: one legged stance and two legged stance while electrical stimulations were applied concurrently or individually to tibialis anterior and triceps surae. Postural responses were assessed by analyzing COP sway path, sum of COP sway measured by a forceplate. The results showed that the direction of the COP shift changed in accordance with the direction of stimulation and showed sensory adaptation as the experiment progressed for two legged stance case. For one legged stance case, concurrent electrical stimulation both sides of muscles was found to be effective for enhancement of postural balance control.

Analysis of Heating Energy in a Korean-Style Apartment Building 3 : The Effect of Room Condition Settings (한국형 아파트의 난방에너지 분석 3 :실내설정조건의 영향)

  • Park, Yoo-Won;Yoo, Ho-Seon;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.722-728
    • /
    • 2005
  • The present paper deals with heating energy estimation in Korean-style apartments, paying special attention to the effect of room condition settings. Two types of heating modes are considered: continuous single-zone and scheduled multi-zone. In the latter, zones during unoccupied periods remain unconditioned. Also analyzed are sensitivities in heating energy with respect to the air change rate and the set temperature. The energy use is estimated with TRNSYS 15, a dynamic load calculation program. Heating energy for the actual residential condition (1.0 ACH and $24^{\circ}C$) appears to be nearly the same as that for a typical design standard (1.5 ACH and $20^{\circ}C$). The air change rate affects heating energy as sensitive]y as the set temperature. For all the simulated cases, the scheduled multi-zone heating mode is more energy-efficient than the continuous single-zone. Heating energy depends appreciably on the shading factor. It is expected that considerable heating energy for apartment houses can be saved by employing a multi-zone mode along with appropriate control devices.

Prediction of Stratification Model for Diffusers in Underfloor Air Distribution System using the CFD (CFD를 활용한 바닥공조시스템 디퓨저의 성층화 모델 예측)

  • Son, Jeong-Eun;Yu, Byeong-Ho;Pang, Seung-Ki;Lee, Kwang Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.105-110
    • /
    • 2017
  • Underfloor air distribution (UFAD) is an air distribution strategy for providing ventilation and space conditioning in buildings. UFAD systems use the underfloor plenum beneath a raised access floor to provide conditioned air through floor diffusers that create a vertical thermal stratification during cooling operations. Thermal stratification has significant effects on energy, indoor air quality, and thermal comfort performance. The purpose of this study was to characterize the influence of a linear bar grille diffuser on thermal stratification in both interior and perimeter zones by developing Gamma-Phi based prediction models. Forty-eight simulations were carried out using a Computational Fluid Dynamics (CFD) technique. The number of diffusers, the air flow supply, internal heat gains, and solar radiations varied among the different cases. Models to predict temperature stratification for the tested linear bar grille diffuser have been developed, which can be directly implemented into dynamic whole-building simulation software such as EnergyPlus.

Simulation of fracture in plain concrete modeled as a composite material

  • Bui, Thanh T.;Attard, Mario M.
    • Computers and Concrete
    • /
    • v.2 no.6
    • /
    • pp.499-516
    • /
    • 2005
  • A composite model is used to represent the heterogeneity of plain concrete consisting of coarse aggregates, mortar matrix and the mortar-aggregate interface. The composite elements of plain concrete are modeled using triangular finite element units which have six interface nodes along the sides. Fracture is captured through a constitutive single branch softening-fracture law at the interface nodes, which bounds the elastic domain inside each triangular unit. The inelastic displacement at an interface node represents the crack opening or sliding displacement and is conjugate to the internodal force. The path-dependent softening behaviour is developed within a quasi-prescribed displacement control formulation. The crack profile is restricted to the interface boundaries of the defined mesh. No re-meshing is carried out. Solutions to the rate formulation are obtained using a mathematical programming procedure in the form of a linear complementary problem. An event by event solution strategy is adopted to eliminate solutions with simultaneous formation of softening zones in symmetric problems. The composite plain concrete model is compared to experimental results for the tensile crack growth in a Brazilian test and three-point bending tests on different sized specimens. The model is also used to simulate wedge-type shear-compression failure directly under the loading platen of a Brazilian test.

Corrosion evaluation of a newly developed high-strength steel in marine environments

  • Jeong, Jin-A;Ko, Kwon-Heum;Lee, Du-Young;Lee, Sang-Il
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.10
    • /
    • pp.883-887
    • /
    • 2016
  • This study aims to evaluate the corrosion behavior of a newly developed high-strength steel in marine environments. Metals used in seawater are easily deteriorated because of the presence of corrosive species such as chloride ions in it. Seawater causes much higher corrosion than fresh water. Thus, the corrosion of steel in marine environment has been recognized as a crucial problem in designing structures which cannot be cathodically protected. In this study, the corrosion resistance of a newly developed high-strength steel was evaluated. Four different specimens were tested to confirm the corrosion resistance. The exposure corrosion test was carried out by exposing the specimens to different marine environments such as atmospheric, tidal, splash, and submerged zones for two years. The specimens taken out from each location were cleaned ultrasonically and chemically prior to the evaluation of their corrosion resistance by the weight loss method. Finally, the pitting depth of the specimens was also measured to evaluate their pitting corrosion. The conditions used for the corrosion test were similar to the environmental conditions. The corrosion test results revealed that the corrosion rate and pitting corrosion of the newly developed high-strength steel was lower than that of the other carbon steels.

Advanced Indentation Studies on the Effects of Hydrogen Attack on Tensile Property Degradation of Heat-Resistant Steel Heat-Affected Zones

  • Choi, Yeol;Jang, Jae-il;Lee, Yun-Hee;Kwon, Dongil;Kim, Jeong-Tae
    • Corrosion Science and Technology
    • /
    • v.2 no.6
    • /
    • pp.266-271
    • /
    • 2003
  • Safety diagnosis of various structural components and facilities is indispensable for preventing catastrophic failure of material by time-dependent and environment accelerating degradation. Also, this diagnosis of operating components should be done periodically for safe maintenance and economical repair. However, conventional standard methods for mechanical properties have the problems of bulky specimen, destructive procedure and complex procedure of specimen sampling. So, a non-destructive and simple mechanical testing method using small specimen is needed. Therefore, an advanced indentation technique was developed as a potential method for non-destructive testing of in-field structures. This technique measures indentation load-depth curve during indentation and analyzes the mechanical properties related to deformation such as yield strength, tensile strength and work-hardening index. In this paper, we characterized the tensile properties including yield and tensile strengths of the V-modified Cr-Mo steels in petro-chemical and thermo-electrical plants. And also, the effects of hydrogen-assisted degradation of the V-modified Cr-Mo steels were analyzed in terms of work-hardening index and yield ratio.

Analysis of Green Space in Daegu Metropolitan (도시공원 녹지의 점유면적 분석 - 대구시를 중심으로 -)

  • SaGong, Jung-Hee;Ra, Jung-Hwa;Lee, Jung-Min
    • Current Research on Agriculture and Life Sciences
    • /
    • v.20
    • /
    • pp.91-98
    • /
    • 2002
  • The objective of this research was to clarify the park area per person in Daegu and to provide the data for distributing the park area with each zone evenly. The results were as follows; 1) The types of green space were classified to 52 classes in forest area, agriculture area and developed area. 2) The analysis of the park area per person, at the 9 dong was presented over area $6m^2$ and at any dong was presented below $1m^2$ area or no green space. 3) The park area rate was presented at the highest in Dalsung-gun, 26.7% and at the lowest in Narn-gu, 1.2%. In comparison to urban park area rate in Daegu 8.9%, over rate was presented 3 zone and in the rest zones were presented below 6%. We concluded that concentration of the park area rate in some zone was serious.

  • PDF