• 제목/요약/키워드: scanning parameter

검색결과 206건 처리시간 0.021초

Evaluation of interfacial tension for poly(methyl methacrylate) and polystyrene by rheological measurements and interaction parameter of the two polymers

  • Sung, Y.T.;Seo, W.J.;Kim, Y.H.;Lee, H.S.;Kim, W.N.
    • Korea-Australia Rheology Journal
    • /
    • 제16권3호
    • /
    • pp.135-140
    • /
    • 2004
  • Morphological and rheological properties of the poly(methyl methacrylate) (PMMA) and polystyrene (PS) blends were studied by scanning electron microscopy (SEM) and advanced rheometric expansion system (ARES). From the SEM results, the PMMA-PS blends showed dispersed morphology and the particle size of the dispersed phase was quite small (0.1~0.6 $\mu\textrm{m}$ compared with other immiscible polymer blends. Values of the interfacial tension of the PMMA-PS blend were obtained from the Choi-Schowalter and the Palierne emulsion models using the storage modulus of the PMMA and PS, and found to be 1.0 and 2.0 mN/m, respectively. The interfacial tension between the PMMA and PS was also calculated from the Flory-Huggins polymer-polymer interaction parameter ($\chi$) and found to be from 0.98 to 1.86 mN/m depending on the molecular weight and composition. Comparing the values of the interfacial tension from the Flory-Huggins polymer-polymer interaction parameter and the values measured by oscillatory rheometer, it is suggested that the interfacial tension of the PMMA-PS blend obtained from the polymer-polymer interaction parameter are in good agreement with the values obtained by rheological measurements.

Defect Shape Recovering by Parameter Estimation Arising in Eddy Current Testing

  • Kojima, Fumio
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.622-634
    • /
    • 2003
  • This paper is concerned with a computational method for recovering a crack shape of steam generator tubes of nuclear plants. Problems on the shape identification are discussed arising in the characterization of a structural defect in a conductor using data of eddy current inspection. A surface defect on the generator tube ran be detected as a probe impedance trajectory by scanning a pancake type coil. First, a mathematical model of the inspection process is derived from the Maxwell's equation. Second, the input and output relation is given by the approximate model by virtue of the hybrid use of the finite element and boundary element method. In that model, the crack shape is characterized by the unknown coefficients of the B-spline function which approximates the crack shape geometry. Finally, a parameter estimation technique is proposed for recovering the crack shape using data from the probe coil. The computational experiments were successfully tested with the laboratory data.

대면적 3 차원 마이크로 형상제작을 위한 스테이지 스캐닝 시스템을 이용한 이광자 흡수 광조형 공정 개발 (Development of Large-area Two-photon Stereolithography Process for the Fabrication of Large Three-dimensional Microstructures)

  • 임태우;손용;이신욱;공홍진;박상후;양동열
    • 한국정밀공학회지
    • /
    • 제25권1호
    • /
    • pp.122-129
    • /
    • 2008
  • Two-photon stereolithography is recognized as a promising process for the fabrication of three-dimensional (3D) microstructures with 100 nm resolution. Generally, beam-scanning system has been used in the conventional process of two-photon stereolithography, which is limited to the fabrication of micro-prototypes in small area of several tens micrometers. For the applications to 3D high-functional micro-devices, the fabrication area of the process is required to be enlarged. In this paper, large-area two-photon stereolithography (L-TPS) employing stage scanning system has been developed. Continuous scanning method is suggested to improve the fabrication speed and parameter study is conducted. An objective lens of high numerical aperture (N.A.) and high strength material were employed in this system. Through this work, 3D microstructures of $600*600*100\;{\mu}m$ were fabricated.

펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정 (Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal)

  • 하욥;장경영
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.77-83
    • /
    • 2006
  • 초음파 비선형성은 적층 구조물 내부의 미세크랙이나 계면 들뜸을 검출하기 위한 수단으로 주목받고 있다. 비선형 초음파의 특징적인 현상은 전파 과정중에 고조파가 발생되는 것이다. 그러므로 비선형성의 정량화를 위해서는 수신된 초음파 신호에 포함된 고조파 성분의 검출이 중요하며, 일반적으로 2차 조화 성분과 기본 주파수 성분의 진폭비가 비선형 파라미터로 이용되고 있다. 그러나 이 비선형 파라미터를 정확하게 추정할 수 있는 방법이 확립되어 있지 않기 때문에 현재까지는 현장적용에 어려움을 겪고 있다. 본 연구에서는 초음파 비선형 파라미터의 정밀 추정을 위한 신호 처리 기술을 제안하고자 한다 이 기술은 파워 스펙트럼과 바이스펙트럼 분석에 기초하며, 특히 본 연구에서는 초음파 현미경(SAM, scanning acoustic microscope)에 사용되는 펄스형 신호로부터 고조파를 검출하는데 주목하였다. 제안된 기법의 유효성은 틈새의 크기가 접촉 중심에서 반경 방향으로 일정하게 증가하는 뉴턴링(Newton-ring)과 칩의 윗면에 국부적인 들뜸을 가진 반도체 샘플에 대한 실험을 통해 검증되었다. 결과적으로 제안된 신호처리기법에 의해 획득된 비선형 파라미터는 계면 들뜸과 좋은 상관성을 보였다.

Mössbauer Spectroscopic Studies of NiZn Ferrite Prepared by the Sol-Gel Method

  • Niyaifar, Mohammad;Mohammadpour, Hory;Rodriguez, Anselmo F.R.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.246-251
    • /
    • 2015
  • This study was aimed to study the effect of Zn content on the hyperfine parameters and the structural variation of $Ni_{1-x}Zn_xFe_2O_4$ for x = 0, 0.2, 0.4, 0.6, and 0.8. To achieve this, a sol-gel route was used for the preparation of samples and the obtained ferrites were investigated by X-ray diffraction, scanning electron microscopy, and $M{\ddot{o}}ssbauer$ spectroscopy. The formation of spinel phase without any impurity peak was identified by X-ray diffraction of all the samples. Moreover, the estimated crystallite size by X-ray line broadening indicates a decrease with increasing Zn content. This result was in agreement with the scanning electron microscopy result, indicating the reduction in grain growth with further zinc substitution. The room-temperature $M{\ddot{o}}ssbauer$ spectra show that the hyperfine fields at both the A and B sites decreased with increasing Zn content; however, the rate of reduction is not the same for different sites. Moreover, the best fit parameter showed that the quadrupole splitting values of B site increased from the pure nickel ferrite to the sample with x = 0.8.

공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화 (3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM))

  • 김현동;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.

체적변수를 이용한 로크웰 경도 모델링 (Rockwell Hardness Modeling Using Volumetric Variable)

  • 진도훈;오상록;윤문철
    • 한국생산제조학회지
    • /
    • 제22권3호
    • /
    • pp.394-401
    • /
    • 2013
  • A new Rockwell hardness (HRC) model using a volumetric parameter by a least square and fractal interpolation method is suggested. The results are also investigated in comparison to real measured hardness data. For this purpose, the measurement of an indented volume is performed using a confocal laser scanning microscope (CLSM), and the captured height encoded image (HEI) is used as an original surface for the calculation of the indented volume. After configuring the surface, the constructed volume is calculated and used as an independent variable for HRC hardness modeling. The hardness model is established using an experimental modeling technique involving a least square algorithm and fractal interpolating model, and this suggested model can be used to reliably predict the Rockwell hardness. These techniques can also be applied to the modeling of the Brinnell and Vickers hardnesses using a volumetric variable.

부화소 단위의 움직임 정보를 고려한 순차주사화 (Sub-pixel motion compensated deinterlacing technique)

  • 박민규;강문기
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2001년도 정기총회 및 학술대회
    • /
    • pp.143-146
    • /
    • 2001
  • HDTV(high-definition television)와 개인용 컴퓨터의 발전에 따라 비월주사(interlaced scanning) 방식의 신호와 순차주사(progressive scanning) 방식의 신호 상호간의 변환에 대한 요구가 점점 늘어나고 있다. 이에 따라 비월주사 방식을 순차주사 방식으로 바꾸어주는 순차주사화(deinterlacing)가 활발히 연구되고 있다. 본 논문에서는 부화소(sub-pixel) 단위의 움직임 정보를 고려한 영상재결합 방법을 기반으로 한 순차주사화 알고리즘을 제안한다. 그러나 국부 움직임이 있는 영역에서는 영상재결합이 효과적이지 않으므로 적절한 문턱값을 이용하여 이러한 영역을 결정하고 에지를 이용한 보간 방법으로 순차주사화 한다. 또한 잘못된 움직임 추정으로 야기되는 문제들을 해결하기 위해, 각 영역과 입력 영상에 따라 다른 움직임 에러를 고려해서 정규화 값(regularization parameter)을 결정함으로 움직임 에러를 효율적으로 제거하였다 제안된 방법은 주관적 측면과 객관적인 측면에서 모두 우수한 결과를 실험적으로 보였다.

  • PDF

주사전자 현미경의 통계적 인자 해석 (Statistical Factor Analysis of Scanning Electron Microscope)

  • 권상희;김병환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.335-337
    • /
    • 2009
  • A scanning electron microscope(SEM) is a system that visualizes complex surface features. The resolution of SEM is affected by each of equipment components. In this study, we examined the effects of the four factors including the beam current, magnification, voltage and working distance. A statistical analysis was conducted to investigate the main and interaction effects. For a systematic characterization, a $2^4$ full factorial experiment was conducted. The $R^2$ of constructed statistical model was 88.9%. The main effect revealed that the current and working distance are dominant factors. Of the interactions, those between the current and voltage yielded the highest interaction. 3D plots generated from the model were used to explore various parameter effects.

  • PDF