• 제목/요약/키워드: scanning microscopy

검색결과 5,699건 처리시간 0.045초

Scanning Electron Microscopic Study of Slime Formations in a Water Injection Station of Oil India Limited in Assam, India

  • Bhagobaty, Ranjan K.;Purohit, S.;Nihalani, M.C.
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.249-253
    • /
    • 2015
  • Microorganisms specifically groups of bacteria exhibiting physiological activities of production of acids are a major cause of concern because of their ability to induce corrosion in oil field pipelines and metal systems involved in water handling. Water Injection Stations as a means of secondary recovery from existing oil producing reservoirs, are often employed in most upstream oil and gas industries to ensure replenishment of voidage, maintenance of reservoir pressure and optimization of crude emulsion throughput. In the present study, scanning electron microscopy of macroscopic orange coloured slime formations sampled from leaking valves on the flow-lines of a Water Injection Stations of Oil India Limited revealed the presence of filamentous bacterial mats in association with diatoms. The species composition of the acidic slime formations from the sampled locations reveal the possible role of acid producing iron oxidizing bacteria (IOB) like Acidithiobacillus ferrooxidans in association with Gomphonema sp. in creating conditions for bio-corrosion.

$14.6K_2O-85.4SiO_2$ 유리에서 Dendrite의 성장 (Dendritic Growth in $14.6K_2O-85.4SiO_2$ Glass)

  • 김성식;박현수;김종희
    • 한국세라믹학회지
    • /
    • 제22권3호
    • /
    • pp.41-45
    • /
    • 1985
  • An experimental study has been carried out to investigate the effect of growth rate V and time on secondary dendrite arm spacing of cristobalite dendrites in $14.6K_2O-85.4SiO_2$ glass by means of x-ray diffractormetry optical microscopy and scanning electron microscopy The scanning lectron microscopy reveals a two-phase layer of dendritic crystals and interstitial melt which grow from the surface at a constant rate. Based on this experiment secondary arm spacing is proportional to V-0.24 and dendrite coarsening during isothermal holding shows that the secondary arm spacing increases with increasing heat-treatment time.

  • PDF

Simple Preparation of One-dimensional Metal Selenide Nanomaterials Using Anodic Aluminum Oxide Template

  • Piao, Yuanzhe
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권1호
    • /
    • pp.35-43
    • /
    • 2012
  • Highly ordered and perforated anodic aluminum oxide membranes were prepared by anodic oxidation and subsequent removal of the barrier layer. By using these homemade anodic aluminum oxide membranes as templates, metal selenide nanowires and nanotubes were synthesized. The structure and composition of these one-dimensional nanomaterials were studied by field emission scanning electron microscopy as well as transmission electron microscopy and energy dispersive X-ray spectroscopy. The growth process of metal selenide inside anodic aluminum oxide channel was traced by investigating the series of samples using scanning electron microscopy after reacting for different times. Straight and dense copper selenide and silver selenide nanowires with a uniform diameter were successfully prepared. In case of nickel selenide, nanotubes were preferentially formed. Phase and crystallinity of the nanostructured materials were also investigated.

Free-standing graphene intercalated nanosheets on Si(111)

  • Pham, Trung T.;Sporken, Robert
    • 전기전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.297-308
    • /
    • 2017
  • By using electron beam evaporation under appropriate conditions, we obtained graphene intercalated sheets on Si(111) with an average crystallite size less than 11nm. The formation of such nanocrystalline graphene was found as a time-dependent function of carbon deposition at a substrate temperature of $1000^{\circ}C$. The structural and electronic properties as well as the surface morphology of such produced materials have been confirmed by reflection high energy electron diffraction, Auger electron spectroscopy, X-ray photoemission spectroscopy, Raman spectroscopy, scanning electron microscopy, atomic force microscopy and scanning tunneling microscopy.

STM investigation of as-cleaved and annealed single crystalline GeTe (111) surface

  • Kim, Ji-ho;Choi, Hoon-hee;Chung, In;Lyo, In-Whan
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.140.2-140.2
    • /
    • 2016
  • Despite the growing interest in GeTe as a archetypal displacive ferroelectric material as well as the basis of related materials used in data-storage applications, atom-resolved study of single crystalline GeTe surface been lacking. Using low temperature scanning tunneling microscopy (STM) and spectroscopy (STS), we investigated as-cleaved and annealed surfaces of GeTe. We found that as-cleaved GeTe(111) surface is composed of at least two kinds of terraces at 78 K. While two terraces show metallic characteristics, they also exhibit distinctive I-V spectra and imaging conditions, with each being attributed to Ge-terminated, and Te-terminated surfaces respectively. GeTe(111) surfaces annealed at moderately elevated temperature introduces intricate networks of extended defect structures. We will present these data and discuss the role of vacancies in the formation of these structures.

  • PDF

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • 제45권4호
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

STM을 이용한 Dipyridinium 유기 단분자막의 모폴로지 관찰 및 전기적 특성 연구 (Study on the Mophology Observation and Electrical Properties of Dipyridinium Organic Monolayer Using STM)

  • 이남석;신훈규;권영수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권2호
    • /
    • pp.51-54
    • /
    • 2005
  • In this work, the attempt has been made to investigate the morphology of self-assembled dipyridinium dithioacetate on Au(111) substrate by Scanning Tunneling Microscopy(STM). Also, we measured electrical properties(I-V) using Scanning Tunneling Spectroscopy(STS). Sample used in this experiment is dipyridinium dithioacetate, which contains thiol functional group, this structure that can be self-assembled easily to Au(111) substrate. The self-assembly procedure was used for two different concentrations, 0.5 mM/ml and 1 mM/ml. Dilute density of sample by 0.5 mM/ml, 1 mM/ml and observed dipyridinium dithioacetate's image by STM after self-assembled on Au(111) substrate. The structure of STM tip-SAMs-Au(111) substrate has been used measurement for electrical properties(I-V) using STS. The current-voltage(I-V) measurement result, observed negative differential resistance(NDR) properties.

주사형 맥스웰응력 현미경에 의한 표면의 전기적 이미지 (Electrical Imaging of Thin Film Surface by Scanning Maxwell-stress Microscopy)

  • 신훈규;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1508-1510
    • /
    • 1998
  • Recent development of scanning probe microscope techniques has made it possible to investigate, not only microscopic surface topography, but also physical and chemical properties on the nanometer-scale. The scanning Maxwell-stress microscopy (SMM) is surface characterization tool capable of mapping both the surface topography and electrical properties, such as surface potential, surface charge dielectric constant of thin films with a nanometer-scale resolution by means of the AC voltage driven oscillation of metal coated cantilever. In this study, we observed the surface potential distribution and molecular ordering in thin films. We have demonstrated that the SMM can be used for imaging surface potential distribution over the film surface and also be used for detecting surface changes in thin films. This is first step towards the understanding of electrical phenomena in organic and inorganic materials, biological system with SMM.

  • PDF

근접장 마이크로파 현미경을 이용한 ITO 박막의 표면저항의 비파괴 관측 특성 연구 (Nondestructive measurement of surface resistance of indium tin oxide(ITO) films by using a near-field scanning microwave microscope)

  • 윤순일;나승욱;유현준;이영주;김현정;이기진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.137-141
    • /
    • 2004
  • 저항특성이 다른 ITO박막의 구조특성과 표면특성을 XRD와 AFM(atomic force microscopy), SEM(scanning electron microscopy)을 이용하여 관측하였다. 접촉방식인 4단자 법을 사용하여 ITO박막의 표면전기저항을 측정하였다. 관측된 구조 및 표면특성을 바탕으로 비파괴 비접촉방식을 이용한 근접장 마이크로파 현미경을 이용하여 얻은 ITO박막의 표면저항특성과 비교 연구하였다.

  • PDF

건조기법을 달리한 SEM 시료상의 비교검토 (Comparison of Scanning Electron Microscopic Specimens Dried with Different Methods)

  • 박창현;장병준;조강용
    • Applied Microscopy
    • /
    • 제25권3호
    • /
    • pp.33-39
    • /
    • 1995
  • To compare the quality of ultrastructural preservation of Scanning Electron Microscopic specimens dried with different methods; pure air-drying, air-drying with using Tetramethylsilane(TMS), four kind of air-drying using Hexamethyldisilazane(HMDS) and critical point drying(CPD), we conducted scanning electron microscopic observation on liver, skeletal muscle and intestinal tissues from laboratory rat treated with each method. In pure air drying group, severe distortion of tissue surface was observed, and in HMDS treated group, only liver tissue showed slight distortion. But in TMS treated group, each tissue showed a good presentation comparable to CPD group. The results suggest that the method of air-drying using TMS may be the former is less expensive and simple be and also time-saving.

  • PDF