• Title/Summary/Keyword: scanning control

Search Result 1,318, Processing Time 0.025 seconds

Surface Modification of Li Metal Electrode with PDMS/GO Composite Thin Film: Controlled Growth of Li Layer and Improved Performance of Lithium Metal Battery (LMB) (PDMS/GO 복합체 박막의 리튬 금속 표면 개질: 리튬전극의 성장 제어 및 리튬금속전지(LMB) 성능 향상)

  • Lee, Sanghyun;Seok, Dohyeong;Jeong, Yohan;Sohn, Hiesang
    • Membrane Journal
    • /
    • v.30 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Although Lithium metal battery (LMB) has a very large theoretical capacity, it has a critical problem such as formation of dendrite which causes short circuit and short cycle life of the LMB. In this study, PDMS/GO composite with evenly dispersed graphene oxide (GO) nanosheets in poly (dimethylsiloxane) (PDMS) was synthesized and coated into a thin film, resulting in the effect that can physically suppress the formation of dendrite. However, PDMS has low ion conductivity, so that we attained improved ion conductivity of PDMS/GO thin film by etching technic using 5wt% hydrofluoric acid (HF), to facilitate the movement of lithium (Li) ions by forming the channel of Li ions. The morphology of the PDMS/GO thin film was observed to confirm using SEM. When the PDMS/GO thin film was utilized to lithium metal battery system, the columbic efficiency was maintained at 87.4% on average until the 100th cycles. In addition, voltage profiles indicated reduced overpotential in comparison to the electrode without thin film.

MORPHOLOGICAL CHANGES OF DENTIN SURFACE TREATED WITH VARIOUS DENTIN SURFACE CONDITIONERS (수종(數種) 표면처리제(表面處理劑)에 의(依)한 상아질(象牙質) 표면(表面)의 형태(形態) 변화(變化)에 관(關)한 연구(硏究))

  • Cho, Jin-Ho;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.323-334
    • /
    • 1988
  • The purpose of this study was to observe the effect of dentin surface conditioners on the dentin surfaces. Freshly extracted human molars were used in this study. They were stored at $4^{\circ}C$ saline solution before experiment. The crown portions of the teeth were cut in various directions by means of wet diamond point to expose dentin which include transverse, vertical oblique, horizontal and oblique cut to the long axis (Fig. 1). Each tooth was then mounted with self curing acrylic resin in brass ring to expose the flattened dentin surfaces. Final finish was accomplished by grinding the dentin specimens with wet No. 180 and No. 600 grit silicon carbide abrasive paper until a 6.0mm in diameter on a dentin surface was exposed without pulp exposure. The specimens were divided into 9 groups according to the modes of dentin treatment procedure. The following surface treatments were applied on these preparation surfaces; Group 1: unetched (control group) after finish with No. 600 silicon carbide abrasive paper. Group 2: etched with 30% phosphoric acid for 60s Group 3: etched with 10-3 solution for 60s Group 4: Cleaned with 5% NaOCl for 30s Group 5: applied Dentin Adhesit Group 6: cleaned with 5% NaOCl followed by applying the Dentin Adhesit$^{(R)}$ Group 7: applied Photo Bond on the unetched dentin followed by applying the Photo Clearfil Bright Group 8: Etched with 30% phosphoric acid followed by applying Photo Bond and Photo Clearfil Bright Group 9: etched with 10-3 solution followed by applying Photo Bond and Photo Clearfil Bright All the specimens were stored in $37^{\circ}C$ under 50% relative humidity for 24 hours before observations. The specimens in 7, 8, and 9 group, omitting the group 1 to 6, were demineralized in 10% HCl for 10s in order to observe the resin tags. All the specimens in each group were then dried at room temperature. The dried specimens were ion coated with Eiko ion coater (Eiko-engineering Co.), and observed in Hitachi S-430 Scanning electron microscope (Hitachi, Co. Tokyo) at 15KV. The following results were obtained as follows; 1. The smear layers were still remained in group 1,2,4,5, and 6. 2. There is no effect of 5% NaOCl and 30% phosphoric acid on the changes of dentin morphology 3. The dentin treated with 10-3 solution, indicating the tubules opened when the smear layer and the dental plug dissolved. 4. In case of applying the bonding agents the resin tag was not formed at the deep area of dentinal tubules, but in case of applying the Dentin Adhesit$^{(R)}$ that was not.

  • PDF

A STUDY ON THE FRACTURE RESISTANCE AND CHARACTERISTICS OF TEETH IN CLASS II CAVITY RESTORATIONS (2급(級) 와동(窩洞) 수복시(修復時) 치아파괴(齒牙破壞) 저항성(抵抗性) 및 귀열양상(龜裂樣相)에 관(關)한 연구(硏究))

  • Joo, Ik-Nam;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.337-348
    • /
    • 1988
  • The purpose of this study was to examine the fracture strength and characteristics of teeth with MOD cavity preparation. Freshly extracted sound maxillary premolars were cleaned and stored in normal saline solution $37^{\circ}C$ for 72 hours before experiments. The roots of teeth were embedded in a self-curing resin, and the exposed crown were maintained in a vertical position by a modelling wax in a brass ring. The MOD cavities were prepared with No. 57 carbide bur under high speed to a depth of 2.0mm and a width of 2.0mm(Fig.1). All the prepared teeth specimens were divided into 7 groups according to the mode of cavity form and restorative materials (Table 1, 2): Group I, unpreapred, intact teeth as control Group II, prepared cavity without restoration Group III, prepared teeth restored with amalgam Group IV, prepared teeth restored with composite resin (P-10) Group V, prepared teeth with beveled enamel margins restored with composite resin (P-10) Group VI, prepared teeth restored with light-cured composite resin (P-30) Group VII, prepard teeth with beveled enamel margins restored with light-cured composite resin (P-30) After placement of restorations, all of the specimens were stored in water at $37^{\circ}C$ for 72 hours before testing. All of the specimens were tested on the Instron Universal Testing machine (No. 6025) in order to evaluate the strength of fracture. One metal ball 5.0mm in diameter contacting the specimens parallel to the occlusal surface was used to in this study (Fig. 1). The fracture characteristics of the specimens were examined with naked eye and in the scanning electron microscope (JSM-20). The results obtained from this study were as follows: 1. The mean fracture strength was the highest in group VI and that in group II was the lowest. 2. The progress of crack of teeth propagated into the pulp cavity. 3. In case of the group of the restored teeth, the crack occurred to be accompanied with cuspal fracture. 4. The crack of restored teeth was initiated along the pulpo-axial line angle of the cavity.

  • PDF

Preparation and Effect of Eudragit E100 Microcapsules Containing Grapefruit Seed Extract on Kimchi (자몽씨 추출물을 함유한 Eudragit E100 미세캡슐의 제조 및 김치에 대한 영향)

  • 김한수;정성기;조성환;구재관;이승철
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.8
    • /
    • pp.1239-1244
    • /
    • 2003
  • Microcapsules were prepared by coacervation method using acetone/liquid paraffin system to control the ripening of kimchi. Eudragit E100, which was soluble at below pH 5.0 in aqueous solution, was used to make microcapsules to be sensitive to acidity of kimchi. The microcapsules with Eudragit E100 containing grapefruit seed extract (GFSE) showed the highest yield of 92.13%, the size of microcapsules was decreasing as increasing the amount of aluminium stearate, a dispersing agent. Morphology of the microcapsules determined by scanning electron microscopy showed spherical forms. GFSE, encapsulated antimicrobial agents, was quickly released at acidic buffer (pH 4,5,6) within 1 storage day. However, 70% of encapsulated GFSE in Eudragit E100 microcapsules was continuously released at pH 7 till 3 days, and it was sustained till 9 days. Characteristics of kimchi containing microcapsules of GFSE were analysed with ripening period. Decease of pH in kimchi was retarded with the added GFSE microcapsules till 2 days of fermentation, but GFSE did not affect pH in kimchi after 3 days. Total numbers of microorganisms and lactic acid microorganisms in kimchi were decreased with increasing the amount of the added GFSE microcapsules, however, the effect of controlled released GFSE from pH sensitive Eudragit E100 microcapsules was hard to detect. These results suggest the possibility of pH sensitive microcapsules for high qualify of kimchi.

The Antitumor Effects of Selenium Compound $Na_5SeV_5O_{18}{\cdot}3H_2O$ in K562 Cell

  • Yang, Jun-Ying;Wang, Zi-Ren
    • Archives of Pharmacal Research
    • /
    • v.29 no.10
    • /
    • pp.859-865
    • /
    • 2006
  • With an approach to study the anti-tumor effects and mechanism of selenium compound, we investigated the anti-tumor activity and mechanism of $Na_5SeV_5O_{18}{\cdot}3H_2O$ (NaSeVO) in K562 cells. The results showed that $0.625{\sim}20\;mg/L$ NaSeVO could significantly inhibit the proliferation of K562 cells in vitro in a time- and concentration-dependent manner as determined by microculture tetrazolium (MTT) assay, the IC50 values were 14.41 (4.45-46.60) and 3.45 (2.29-5.22) mg/L after 48 hand 72 h treatment with NaSeVO respectively. In vivo experiments demonstrated that i.p. administration of 5, 10 mg/kg NaSeVO exhibited an significant inhibitory effect on the growth of transplantation tumor sarcoma 180 (S180) and hepatoma 22 (H22) in mice, with inhibition rate 26.8% and 58.4% on S180 and 31.3% and 47.4% on H22, respectively. Cell cycle studies indicated that the proportion of G0/G1 phase was increased at 2.5 mg/L while decreased at 10 mg/L after treatment for 24, 48 h. Whereas S phase was decreased at 2.5-5 mg/L and markedly increased at 10 mg/L after treatment for 48 h. After treatment for 24 h, 10 mg/L NaSeVO also markedly increased S and G2/M phases. Take together, the result clearly showed that NaSeVO markedly increased S and G2/M phases at 10 mg/L. The study of immunocytochemistry showed that the expression bcl-2 is significantly inhibited by 10 mg/L NaSeVO, and bax increased. Morphology observation also revealed typical apoptotic features. NaSeVO also significantly caused the accumulation of $Ca^{2+}$ and $Mg^{2+}$, reactive oxygen species (ROS) and the reduction of pH value and mitochondrial membrane potential in K562 cells as compared with control by confocal laser scanning microscope. These results suggest that NaSeVO has anti-tumor effects and its mechanism is attributed partially to apoptosis induced by the elevation of intracellular $Ca^{2+}$, $Mg^{2+}$ and ROS concentration, and a reduction of pH value and mitochondria membrane potential (MMP).

A comparative study of physical properties of $TiO_2$ thin films according to a coating method on orthodontic wires and brackets (교정용 와이어 및 브라켓에 이산화티탄 광촉매 코팅 시 코팅방법에 따른 비교연구)

  • Koh, Eun-Hee;Cho, Jin-Hyoung
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.451-464
    • /
    • 2006
  • The purpose of this study was to search for an appropriate method of coating $TiO_2$ on orthodontic appliances. $TiO_2$ thin films were deposited on orthodontic wires and brackets using sol-gel, CVD (Chemical Vapor Deposition) and PE-CVD (Plasma Enhanced-CVD) methods. The roughness of $TiO_2$-coated surfaces was investigated via scanning electron microscope (SEM) and adhesive strength of $TiO_2$ thin films was measured by adhesive tape pull test. Methylene blue degradation test was carried out to evaluate the photocatalytic activity of $TiO_2$ and the corrosion resistance of $TiO_2$ thin films against fluoride solution was also analyzed by observing the surfaces of $TiO_2$-coated wires and brackets via SEM after immersion in sodium fluoride solution. Through the comparison of properties and photocatalytic activity of $TiO_2$ thin films according to the coating methods, the following results were obtained. Smoother surfaces of $TiO_2$ thin films were generated by CVD or PE-CVD methods than through the sol-gel method or the control. Adhesive strength of the $TiO_2$ thin films was highest in PE-CVD and gradually became lower in the order of CVD, then the sol-gel method. Photocatalytic activity of $TiO_2$ thin films on methylene blue was the highest in PE-CVD and gradually became lower in the order of CVD, then the sol-gel method. Corrosion resistance of $TiO_2$ thin films against fluoride solution was stronger in CVD and PE-CVD methods than in the sol-gel method. The results of this study suggest that the CVD or PE-CVD methods is more appropriate than the sol-gel method for $TiO_2$ coating on orthodontic wires and brackets.

THE EFFECT OF VARIOUS SURFACE TREATMENT METHODS ON THE OSSEOINTEGRATION (임플랜트의 표면처리 방법이 골유착에 미치는 영향에 관한 연구)

  • Choi Jeong-Won;Kim Kwang-Nam;Heo Seong-Joo;Chang Ik-Tae;Han Chong-Hyun;Baek Hong-Gu;Choi Yong-Chang;Wennerberg Ann
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.71-83
    • /
    • 2001
  • The purpose of this study was to compare the effects of various surface treatments by measuring removal torque on bone healing around titanium implants. 40 Screw-shaped cp titanium implants with length of 4mm, outer diameter of 3.75mm, and pitch-height of 0.5mm were used Group 1 was left as machined(control), Group 2 was blasted with $50{\mu}m\;Al_2O_3$, group 3 was blasted and etched in etching solution($NH_4OH : H_2O_2:H_2O= 1 : 1 : 5$) at $90^{\circ}C$ for 1 minute group 4 was blasted and oxidated under pure oxygen at $800^{\circ}C$. The implant surface roughness was analyzed with SEM and CLSM(Confocal Laser Scanning Microscope) and implants were placed in proximal tibial metaphysis of 10 New Zealand White rabbits. After 3 months of healing period, removal torque of each implant was measured to compare bone healing around implant. The results obtained were as follows 1. In SEM view, blasting increased the roughness of the surface, but etching of that rough surface decreased the roughness due to the removal of the tip of the peak. Oxidation also decreased the roughness due to formation of needle-like oxide grains on the implant surface. 2. The Sa value from CLSM was least in the machined group($0.47{\mu}m$), greatest in blasted group($1.25{\mu}m$), and the value decreased after etching($0.91{\mu}m$) and oxidation($0.94{\mu}m$). 3. The removal torque of etched group(24.5Ncm) was greater than that of machined group(16.7Ncm) (P<0.05), and was greatest in the oxidated group(40.3Ncm) and the blasted group(34.7Ncm).

  • PDF

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

MEASUREMENT OF MAXILLARY SINUS VOLUME FOR THE PLACEMENT OF GRAFT MATERIAL - A CASE CONTROL STUDY USING CT IMAGE (상악동 골이식술을 위한 이식재의 부피 측정 - CT를 이용한 환자 대조군 연구)

  • Kim, Hyung-Wook;Lee, Seul-Ki;Chung, Jae-An;Shin, Jin-Eob;Um, Yun-Sub;Kim, Ki-Young;Kim, Jong-Sik;Song, Yun-Jung;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.511-517
    • /
    • 2007
  • Purpose: The aim of this study is to determine whether a difference in the amount of bone graft material is needed between edentulous patients and dentulous patients and to calculate the amount of augmentation for a sinus lift procedure. Methods: 19 patients(20 sinuses) were included to measure maxillary sinus volume. Facial CT scanning was performed using MX 8000 IDT CT devices(Philips, USA). And it was used for IDLvm(The IDL Virtual Machine) 6.0, CT Volume Analyzer Ver 2.3 program to measure maxillary sinus volumes Results: At edentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.56{\pm}0.13cm^3$(5mm height), $2.35{\pm}0.57cm^3$(10mm height), $4.85{\pm}1.10cm^3$(15mm height). At dentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.41{\pm}0.18cm^3$(5mm height), $1.76{\pm}0.42cm^3$(10mm height), $3.80{\pm}0.84cm^3$ (15mm height). A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume.(p=0.027, p=0.018, p=0.044) Conclusions: A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume. Detailed preoperative knowledge of sinus lift augmentation volume is helpful in determining the appropriate amount of the bone graft material.

Quality Comparison between Gamma Irradiation and Freeze Drying Methods in Preparing Kimchi for the Long-term Storage (장기저장이 가능한 김치제조를 위한 감마선 조사와 동결건조법의 품질비교)

  • Park, Jin-Gyu;Park, Jae-Nam;Han, In-Jun;Song, Beom-Seok;Kim, Jae-Hun;Lee, Ju-Woon;Hwang, Han-Joon;Kim, Young-Duk;Byun, Myung-Woo
    • Food Science and Preservation
    • /
    • v.15 no.1
    • /
    • pp.9-14
    • /
    • 2008
  • This study compared microbial load, texturre, histological properties, and sensory characteristics of gamma-irradiated (20 kGy) Kimchi and freeze-dried Kimchi under condition; of long-tenn storage. immediately after irradiation, no aerobic bacteria were detected, but microbial load of freeze-dried Kimchi decreased by only 1 log cycle in comparision with the nonirradiated control sample. The firmness of irradiated Kimchi was significantly higher than that of rehydrated freeze-dried Kimchi (p<0.05). Scanning electron microscopy showed collapse of the microstructure in epidermis tissues of rehydrated Kimchi. 'The sensory scores for color, texture, and taste of irradiated Kimchi were higher than those for rehydrated freeze-dried Kimchi.