• Title/Summary/Keyword: scanning control

Search Result 1,325, Processing Time 0.048 seconds

Comparison of shear bond strength according to various surface treatment methods of zirconia and resin cement types (지르코니아의 다양한 표면처리 방법과 레진시멘트 종류에 따른 전단결합강도 비교)

  • Bae, Ji-Hyeon;Bae, Gang-Ho;Park, Taeseok;Huh, Jung-Bo;Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.153-163
    • /
    • 2021
  • Purpose: The aim of this study was to evaluate the effects of four surface treatment methods to improve zirconia roughness and three types of resin cement on the shear bond strength (SBS). Materials and methods: A total of 120 zirconia blocks were randomly divided into four surface treatments: non-treatment (Control), airborne-particle abrasion (APA) with 50 ㎛ Al2O3 (APA50), APA with 125 ㎛ Al2O3 (APA125), and ZrO2 slurry (ZA). Three resin cements (Panavia F 2.0, Superbond C&B, and Variolink N) were applied to the surface-treated zirconia specimens. All specimens were subjected to SBS testing using a universal testing machine. The surface of the representative specimens of each group was observed by scanning electron microscope (SEM). SBS data were analyzed with oneway ANOVA, two-way ANOVA test and post-hoc Tukey HSD Test (α=.05). Results: In the surface treatment method, APA125, APA50, ZA, and Control showed high shear bond strength in order, but there was no significant difference between APA125 and APA50 (P>.05). Also, ZA showed significantly higher shear bond strength than Control (P<.05). In the resin cement type, Panavia F 2.0, Superbond C&B, and Variolink N showed significantly higher shear bond strength in order (P<.05). In SEM images, the zirconia surfaces of the APA50 and APA125 showed quite rough and irregular shapes, and the zirconia surface of the ZA was observed small irregular porosity and rough surfaces. Conclusion: APA and ZrO2 slurry were enhanced the surface roughness of zirconia, and Panavia F 2.0 containing MDP showed the highest shear bond strength with zirconia.

Surface Roughness and Cariogenic Microbial Adhesion after Polishing of Smart Chromatic Technology-based Composite Resin (Smart Chromatic Technology 기반 복합 레진의 폴리싱 이후 표면 거칠기 및 우식원성 미생물 부착 )

  • Haesong Kim;Juhyun Lee;Haeni Kim;Howon Park
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.1
    • /
    • pp.65-74
    • /
    • 2023
  • This study compared the surface roughness and microbial adhesion characteristics of Omnichroma, a novel composite resin developed using "smart chromatic technology", with those of two other conventional composite resins with different filler compositions. A total of 144 specimens were fabricated using 3 types of composite resins: Omnichroma (nano-spherical), Filtek Z350XT (nanofill), and Tetric N-Ceram (nanohybrid) and, divided into 3 groups of 48. Finishing was performed using tungsten carbide burs. Specimens were then divided into 3 subgroups using different polishing methods: Control, SofLex, and PoGo. Surface roughness was analyzed quantitatively and qualitatively using an atomic force microscope and a scanning electron microscope. Microbial adhesion was assessed by culturing Streptococcus mutans on the specimens for 24 hours and then measuring colony-forming units attached to the upper surface. The surface roughness (Ra) of Omnichroma was 0.123 ㎛ after finishing, and it exhibited a smooth surface compared to the other resins. However, after polishing, there were no significant differences in the surface roughness between the three composite groups, regardless of the polishing methods. The surfaces of the Control subgroups were significantly rougher than those of the SofLex subgroups in all 3 composite groups. However, except for Tetric N-Ceram, there were no significant differences between the Control and PoGo subgroups in the other composite groups. Microbial adhesion assessment showed no significant differences between any of the 3 composite resin subgroups; however, Omnichroma exhibited higher microbial adhesion than the other two composites. No significant correlation was observed between surface roughness and microbial adhesion.

Experimental activation of cryptosporidiosis in mice by immunosuppression (면역억제에 의한 마우스의 Cryptosporidium 발현 실험)

  • 채종일;신손문
    • Parasites, Hosts and Diseases
    • /
    • v.28 no.1
    • /
    • pp.31-38
    • /
    • 1990
  • Cryptosporidium, a coccidian parasite first described by Tyzzer (1907) from a laboratory mouse, has become an important human enteric pathogen causing overwhelming diarrhea especially in immunocompromised patients such as AIDS. This parasite has been reported from over 20 countries and is recognized as a cosmopolitan species. In Korea, however, thEre has been no report on human as well as animal cryptosporidiosis. This study was performed so as to verify the presence of Cryptosporidium in Korea by activating the parasite from laboratory mice by immunosuppression. Total 65 conventionally.bred ICR mice including a control (5 mice) and 3 experimental groups (20 each) were used for this study. Group I was immunosuppressed with Prednisolone injection (1 mg IM, every other day) for 7 weeks. Group II (prednisolone injection and tetracycline administration) and Group III. (prednisolone injection and trimethoprim-sulfamethoxazole administration) were prepared to observe the effect of antibacterial agents on the activation of cryptosporidiosis. In fecal examinations of mice Cryptosporidium oocysts($4-6{\mu\textrm{m}}$ in size) were detected from 1 week after the start of immunosuppression and the mice began to die. In H-E stained tissue sections of the lower jejunum, numerous very small ($2~4{\;}{\mu\textrm{m}}$), dense, ovoid or spherical, slightly basophilic bodies were seen attached on the free border of mucosal epithelial cells. In scanning and transmission electron microscopic observations, these organisms were identified as various developmental stages of Cryptosperidium. The species is considered to be C. parvum. Cryptosporidiosis was activated not only in Group I but also in Group II and III, indicating no protective effects of the antibacterial agents used, although the mice in Group II and III lived longer than those in Group I. The present study confirmed that Cryptosporidium exists in laboratory mice bred in Korea, and predicts possible occurrence of human cryptosporidiosis in Korea.

  • PDF

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

Synthesis of Nano-Sized Y3Al5O12:Ce3+ Phosphors Prepared by High Energy Beads Milling Process and Their Luminescence Properties

  • Song, Hee-Jo;Kim, Dong-Hoe;Park, Jong-Hoon;Han, Byung-Suh;Hong, Kug-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.386-386
    • /
    • 2012
  • For white light emitting diode (LED) applications, it has been reported that Y3Al5O12:Ce3+ (YAG:Ce) in nano-sized phosphor performs better than it does in micro-sized particles. This is because nano-sized YAG:Ce can reduce internal light scattering when coated onto a blue LED surface. Recently, there have been many reports on the synthesis of nano-sized YAG particles using bottom-up method, such as co-precipitation method, sol-gel process, hydrothermal method, solvothermal method, and glycothermal method. However, there has been no report using top-down method. Top-down method has advantages than bottom-up method, such as large scale production and easy control of doping concentration and particle size. Therefore, in this study, nano-sized YAG:Ce phosphors were synthesized by a high energy beads milling process with varying beads size, milling time and milling steps. The beads milling process was performed by Laboratory Mill MINICER with ZrO2 beads. The phase identity and morphology of nano-sized YAG:Ce were characterized by X-ray powder diffraction (XRD) and field-emission scanning electron microscopy (FESEM), respectively. By controlling beads size, milling time and milling steps, we synthesized a size-tunable and uniform nano-sized YAG:Ce phosphors which average diameters were 100, 85 and 40 nm, respectively. After milling, there was no impurity and all of the peaks were in good agreement with YAG (JCPDS No. 33-0040). Luminescence and quantum efficiency (QE) of nano-sized YAG:Ce phosphors were measured by fluorescence spectrometer and QE measuring instrument, respectively. The synthesized YAG:Ce absorbed light efficiently in the visible region of 400-500 nm, and showed single broadband emission peaked at 550 nm with 50% of QE. As a result, by considering above results, high energy beads milling process could be a facile and reproducible synthesis method for nano-sized YAG:Ce phosphors.

  • PDF

Comparison of Cariogenicity of Bovine Milk and Low-fat Milk on Streptococcus mutans Biofilm (국내 시판 우유와 저지방 우유의 Streptococcus mutans 세균막에 대한 우식원성 비교)

  • Hwang, Minseon;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.2
    • /
    • pp.170-179
    • /
    • 2017
  • The purpose of this study was to compare the cariogenicity of commercially available bovine milk and low-fat milk in a biofilm model using the CDC Biofilm Reactor. Streptococcus mutans ATCC 25175 biofilms were formed on saliva coated bovine enamel slabs in a CDC Biofilm Reactor. Biofilms were exposed three times per day to one of the following materials: commercial whole milk (fat content: 3.4%), low-fat milk (fat content: 1%), or 0.9% NaCl. Medium pH was measured at different time points. After 5 days, biofilms were separated from slabs to evaluate the CFUs. The biofilm thickness was observed by confocal laser-scanning microscopy (CLSM). Enamel slab's demineralization was assessed by measuring surface microhardness before and after the experiment. For microhardness and CFUs assessment, no significant difference was found among the three groups. All groups showed similar pattern of medium pH change and biofilm thickness. Our results showed that there was no difference in the cariogenicity between whole milk and low-fat milk. Both milks were relatively non-cariogenic compared to the control group.

Thickness optimization of the bulk GaN single crystal grown by HVPE processing variable control (HVPE 법에서의 공정변수 조절에 의한 bulk GaN 단결정의 두께 최적화)

  • Park, Jae Hwa;Lee, Hee Ae;Lee, Joo Hyung;Park, Cheol Woo;Lee, Jung Hun;Kang, Hyo Sang;Kang, Suk Hyun;Bang, Sin Young;Lee, Seong Kuk;Shim, Kwang Bo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.2
    • /
    • pp.89-93
    • /
    • 2017
  • GaN single crystals were grown by controlling of various processing parameters such as growing temperature, V/III ratio and growing rate. We optimized thickness of bulk GaN single crystal by analyzing defect of surface and inside of the GaN single crystal for application to high brightness and power device. 2-inch bulk GaN single crystals were grown by HVPE (hydride vapor phase epitaxy) on sapphire and their thickness was 0.3~7.0 mm. Crystal structure of the grown bulk GaN was analyzed by XRD (X-ray diffraction). The surface characteristics of the grown bulk GaN were observed by OM (optical microscope) and SEM (scanning electron microscopy) with measuring EPD (etch pits density) of the GaN crystals.

Development of Shampoo Formulated by EPA for the Damaged Hair (손상 모발을 위한 EPA 함유 샴푸 개발)

  • Lee, Bo-Reum;Lee, Ok-Sang;Kang, Tae-Jin;Lim, Sung-Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.3
    • /
    • pp.256-269
    • /
    • 2011
  • Omega-3 fatty acids are a specific type of unsaturated fat that the body cannot manufacture on its own, so they must be obtained from food which is essential fatty acids (EFAs). Omega-3 fatty acids consist of three types which are a-Linolenic Acid (ALA), Eicosapentaenoic (ELA), and Docosahexaenoic Acid (DHA). Especially, EFAs help to prevent skin and hair drying, acne, eczema, prevention from allergies, brittle nails, rashes, and tiny lumps. The aim of this study is to investigate improvement and protection for hair damaged by chemical treatment with omega-3 formulated shampoo. We selected virgin hair sample and divided into two groups for bleaching once and three times and then damaged hair by changing the number of hair bleaching (twice with interval of 15 minutes). Each bleached hair was treated by five different kinds of shampoo (Control, Horse shampoo, DHA shampoo, EPA shampoo, Omega-3 shampoo mixture). Apart from this, EPA/DHA 2, 5, 8, 10 and 12% shampoo were prepared and treated to hair for comparing rate of progress in damaged hair. To quantify improved condition of damaged hair, we performed Scanning Electron Microscope (SEM) for ultrastructure of damaged hair fraction, measurement of thickness change and BCA Protein Assay for recovery rate of damaged hair. The moisture in hair was measured by Thermal analysis machine. In results, we observed the particle of hair surface damaged by bleaching treatment were well improved with treatment with EPA and DHA shampoo. Also, quantity of protein was lowered with higher concentration of EPA & DHA i.e., 8 and 12 % then compared with horse oil shampoo in three times treatment group. It shows that bleached hair have been recovered by treating rapidly and get protective coat. In conclusion, EPA and DHA shampoo improved damaged hair, especially with EPA / DHA 12% shampoo. Also, EPA shampoo could protect the damaged hair depending on increasing concentration of EPA. Therefore, we conclude omega-3 shampoo could make damaged hair protect and get healthy hair environment.

A Study on the Physical Properties and Cytotoxicity of Tooth Ash and Dental Procelain (치아회분(齒牙灰粉)과 도재복합(陶材複合) 매식체(埋植體)의 물리적(物理的) 성질(性質) 및 세포배양(細胞培養)에 의(依)한 조직친화성(組織親和性)에 관(關)한 연구(硏究))

  • Hoh, Ki-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.51-68
    • /
    • 1984
  • The purpose of this study is primarily to test the use value of tooth ash as an alternative material of the synthetic hydroxyapatite. For this purpose the author performed the experimental study to investigate the phsyical properties of sintered tooth ash and its histocompatibility in vitro. The tooth ash was made by incinerating procedure at $650^{\circ}C,\;750^{\circ}C,\;850^{\circ}C,\;950^{\circ}C\;and\;1050^{\circ}C$ respectively. The composition of tooth ash was analyzed and X-ray diffraction was done. The experimental specimens were molded to the cylinderical form 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$, which were divided into two groups; the one is sintered tooth ash at $1100^{\circ}C$ and the other is fired mixture of tooth ash and dental porcelain mixed to the weight ratio of 4:6, 5:5, 6:4 and 7:3. The physical propoerties of the sintered specimens were examined and their microstructure was observed under the Scanning Electron Microscope. The results obtained were as followings: 1. The difference of the tooth ash composition depending on incinerating temperature was of no significance, but the $CO_2$ disappeared from $950^{\circ}C$. 2. X-ray diffraction showed the tooth ash was mainly composed of hydroxyapatite and a small amount of - white lockite. But phase transformation was not disclosed. 3. The microstructure of the sintered specimens of the ashed tooth powder was of no difference in the structure and grain size accompanying the ashed temperature, but sintering ability seemed to be the best in the specimen incinerated at $950^{\circ}C$. 4. There was good wettability in the mixed sintered specimens of the ashed tooth powder and the porcelain powder. 5. The compressive strength of the sintered specimens of the tooth ash incinerated at $950^{\circ}C$ was the highest with $589.75kg/cm^2$ and the porosity and the absorption were the lowest as well. 6. The mixed sintered specimens of the tooth ash and porcelain powder was good in the physical properties in the case of mixed weight ratio of 6:4. 7. The animal fibroblast cultures with porcelain showed increase in the cell number, whereas the tooth ash showed a small degree of growth inhibition. But the difference of cell multiplication efficiency between control cultures and test cultures with tooth ash was not observed.

  • PDF

The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin

  • Su, Naichuan;Yue, Li;Liao, Yunmao;Liu, Wenjia;Zhang, Hai;Li, Xin;Wang, Hang;Shen, Jiefei
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.214-223
    • /
    • 2015
  • PURPOSE. To measure the surface loss of dental restorative zirconia and the short-term bond strength between an indirect composite resin (ICR) and zirconia ceramic after various sandblasting processes. MATERIALS AND METHODS. Three hundred zirconia bars were randomly divided into 25 groups according to the type of sandblasting performed with pressures of 0.1, 0.2, 0.4 and 0.6 MPa, sandblasting times of 7, 14 and 21 seconds, and alumina powder sizes of 50 and $110{\mu}m$. The control group did not receive sandblasting. The volume loss and height loss on zirconia surface after sandblasting and the shear bond strength (SBS) between the sandblasted zirconia and ICR after 24-h immersion were measured for each group using multivariate analysis of variance (ANOVA) and Least Significance Difference (LSD) test (${\alpha}$=.05). After sandblasting, the failure modes of the ICR/zirconia surfaces were observed using scanning electron microscopy. RESULTS. The volume loss and height loss were increased with higher sandblasting pressure and longer sandblasting treatment, but they decreased with larger powder size. SBS was significantly increased by increasing the sandblasting time from 7 seconds to 14 seconds and from 14 seconds to 21 seconds, as well as increasing the size of alumina powder from $50{\mu}m$ to $110{\mu}m$. SBS was significantly increased from 0.1 MPa to 0.2 MPa according to the size of alumina powder. However, the SBSs were not significantly different with the sandblasting pressure of 0.2, 0.4 and 0.6 MPa. The possibilities of the combination of both adhesive failure and cohesive failure within the ICR were higher with the increases in bonding strength. CONCLUSION. Based on the findings of this study, sandblasting with alumina particles at 0.2 MPa, 21 seconds and the powder size of $110{\mu}m$ is recommended for dental applications to improve the bonding between zirconia core and ICR.