• Title/Summary/Keyword: scan test

Search Result 857, Processing Time 0.031 seconds

Testable Design Technique for Digital Signal Processor (디지탈 신호처리 프로세서의 테스터블 디자인 기법)

  • 김동석;김보환;이기준;최해욱
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.5
    • /
    • pp.749-758
    • /
    • 1995
  • There are many testable design techniques, among which Scan path and BIST techniques are mainly used. In this paper, the increase of design effectiveness is discussed, when these techniques are applied to the practical implementation of chips. The following techniques are presented : 1) Blocks are commonly used to reduce test time without hardware increase, 2) MUX is used to implement the shortest Scan path, 3) Scan register is used which controls and/or observes several blocks to avoid the increase of hardware.

  • PDF

$H_{\infty}$ Control of Seeker Scan-Loop using LSDP (LSDP를 이용한 탐색기 주사루프의 $H_{\infty}$ 제어)

  • Lee, Ho-Pyeong;Song, Chang-Seop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.1
    • /
    • pp.78-86
    • /
    • 1995
  • $H_{\infty}$ Controller of seeker scan-loop is designed using LSDP proposed by McFarlane. The performance and robustness of $H_{\infty}$ controller are analyzed using robustness theorems by Lehtomaki and compared with those of the LQG/LTR controller. Especially, structured singular value .mu. -test of Doyle is used to evaluate robust performance of seeker scan-loop. It is demonstated that seeker scan-loop by $H_{\infty}$ controller is very robust to model uncertainties described by additive and multiplicative perturbations.

  • PDF

A Study on the Efficient 3D Scanning Method for Digital Twin Configuration in Construction Site (건설현장의 디지털 트윈 구성을 위한 효율적인 3D 스캐닝 방법에 관한 연구)

  • Kim, Seong-Hun;Kim, Tae-Han;Eom, Ire;Won, Jong-Chul
    • Journal of KIBIM
    • /
    • v.12 no.3
    • /
    • pp.39-51
    • /
    • 2022
  • 3D scan technology can utilize real spatial information as it is in virtual space, so it can be usefully used in various fields such as reverse engineering of buildings and process management. Recently, with the development of ICT technology, more precise scan data can be obtained, and scan processing time has also been greatly reduced. In addition, the combination of software and scanning equipment used in 3D scanning technology is very diverse, and results are very different depending on which technology is used. Accordingly, there is a problem that it is difficult for a user who has no experience in 3D scanning technology to determine which technology and equipment should be used to obtain good results. In this study, 3D scan technologies mainly used at home and abroad are investigated, classified, and tested at actual construction sites to suggest considerations and suitable 3D scan methods when using 3D scans in construction sites. The test results were analyzed to evaluate the time it takes to scan, the final quality, and the user's convenience according to each technology method.

Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan (악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교)

  • Lee, Kyung-Han;Choi, Chang-Woon;Bang, Yung-Jue;Chung, Jun-Key;Chung, Hong-Keun;Lee, Myoung-Chul;Kim, Byoung-Kook;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

Usefulness Evaluation 'Ankle Stress View Compared with MRI scan' of Subacute Ankle Sprain (아급성기 발목염좌에 대한 Stress View와 MRI검사 대비 유용성 평가)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.201-205
    • /
    • 2011
  • Subacute Ankle Sprain patients, 3 tests have been acknowledge for diagnostic precision and thus most commonly used to test their soft tissues, muscles, and ligaments: ankle stress-valgus test, anterior-draw test, and MRI scan. Although not much different from the rest two in its diagnostic value, MRI costs patients some money and time. Also, we have reached the conclusion through an experiment with a group of patients in a certain hospital that the rest two methods is as efficient and useful as MRI in diagnosing ankle joint patients.

Detectability Measurement of GPR for Buried Target in Self-Designed Test Field (자체 제작한 시험장에서의 GPR의 매설물 검출능력에 관한 측정)

  • Son, Soo-Jung;Shin, Byoung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.322-328
    • /
    • 2000
  • In this paper, we were investigated the detectability on various specimen in self-designed test field using the GPR system with three antenna elements. The GPR system was constantly radiated 730MHz frequency. To examine the detectability on various condition, the test were experimented using different materials, size and buried depth. As an adjusted wave-propagation velocity, the location of hyperbolic curve pattern were displayed B-scan CRT. And the pattern was exactly positioned when it was compared to the real buried-depth. Therefore, we can confirm similarity between the wave-propagation velocity and previous results.

  • PDF

Compression-Friendly Low Power Test Application Based on Scan Slices Reusing

  • Wang, Weizheng;Wang, JinCheng;Cai, Shuo;Su, Wei;Xiang, Lingyun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.4
    • /
    • pp.463-469
    • /
    • 2016
  • This paper presents a compression-friendly low power test scheme in EDT environment. The proposed approach exploits scan slices reusing to reduce the switching activity during shifting for test scheme based on linear decompressor. To avoid the impact on encoding efficiency from resulting control data, a counter is utilized to generate control signals. Experimental results obtained for some larger ISCAS'89 and ITC'99 benchmark circuits illustrate that the proposed test application scheme can improve significantly the encoding efficiency of linear decompressor.

Effect of Oral Health Education with Q-Scan in Preschool Children (Q-Scan을 이용한 학령전기 아동의 구강보건교육 효과)

  • Kim, Na-Yeon;Lee, Su-Young
    • Journal of dental hygiene science
    • /
    • v.15 no.6
    • /
    • pp.696-702
    • /
    • 2015
  • The purpose of this study was to evaluate the effect of oral health education with Q-scan for preschool children. The 59 children were divided into two groups, one with Q-scan and the other with dentiform, and they were evaluated by interview questionnaire and measurement of dental plaque index using Quigley-Hein index. Using SPSS ver. 18.0 for statistical analysis, paired t-test and Independent t-test were carried out for dental plaque index change and chi-square independence test for change between before and after oral health education. The result of this study revealed that the dental plaque index of the children showed significant decrease of 12% more in the experimental group (p<0.001). Both groups showed significant difference in knowledge about fluorine (p<0.05) and the percentage of correct answers showed significant increase in questions about bad food for teeth (p<0.05). In attitude toward oral health, the experimental group showed significant difference in every variable (p<0.05), and the control group showed significant difference in regular oral examination and frequency of toothbrushing (p<0.05). The experimental group showed significant result (p<0.05) with increase in the percentage of correct answers for the question about how to hold a toothbrush and decrease in the percentage of correct answers for the question about how to apply toothpaste, while the control group did not show significant difference in any variable. Therefore, Q-scan as an appropriate tool for motivation, provides effective educational methods in oral health education.

A Study on Clinical Diagnosis of Temporomandibular Joint Disorders Using Bone Scan (골스캔을 이용한 측두하악관절장애의 임상진단에 관한 연구)

  • Bong-Jik Seo;Myung-Yun Ko
    • Journal of Oral Medicine and Pain
    • /
    • v.21 no.1
    • /
    • pp.103-113
    • /
    • 1996
  • The author examined the clinical signs and symptoms , routine radiographs, laboratory test and bone scan in 73 subjects with TMJ disorders and studied the responses of clinical test on patients, the distribution of signs and symptoms of joints, the simple uptake rate(SUR) of affected joints , the SUR of subclassified groups of TMJ disorders, active joints of subclassified groups of TMJ disorders and the SUR of joints with noises. The obtained results were as follows : 1. The percentage of joint pain on palpation, joint noises joint pain on function, mandibular dysfunction and active finding of bone scan in aptients with TMJ disorders were higher 2. The SUR was higher in joints affected by joint pain on function, joint pain on palpation, mandibular dysfunction and creptius. 3. The SUR of osteoarthrosis was the lowest. 4. The percentage of active joints were the highest in joints with discdisplacement without reduction, and followed by osteoarthritis, and disc displacement with reduction. 5. The SUR of TMJ showing joint noises only was lower.

  • PDF

Efficacy of I-123/I-131 Metaiodobenzylguanidine Scan as A Single Initial Diagnostic Modality in Pheochromocytoma: Comparison with Biochemical Test and Anatomic Imaging (갈색세포종의 초기 진단에서 I-123/I-131 Metaiodobenzylguanidine 스캔의 단일 검사로써의 진단 성능: 생화학적 검사, 해부학적 영상과 비교)

  • Moon, Eun-Ha;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.436-442
    • /
    • 2009
  • Purpose: We underwent this study to evaluate the diagnostic potential of I-123/I-131 metaiodobenzylguanidine (MIBG) scintigraphy alone in the initial diagnosis of pheochromocytoma, compared with biochemical test and anatomic imaging. Materials & Methods: Twenty two patients (M:F=13:9, Age: $44.3{\pm}\;19.3$ years) having the clinical evaluation due to suspicious pheochromocytoma received the biochemical test, anatomic imaging modality (CT and/or MRI) and I-123/I-131 MIBG scan for diagnosis of pheochromocytoma, prior to histopathological confirmation. MIBG scans were independently reviewed by 2 nuclear medicine physicians. Results: All patients were confirmed histopathologically by operation or biopsy (incisional or excisonal). In comparison of final diagnosis and findings of each diagnostic modality, the sensitivities of the biochemical test, anatomic imaging, and MIBG scan were 88.9%, 55.6%, and 88.9%, respectively. And the specificities of the biochemical test, anatomic imaging, and MIBG scan also were 69.2%, 69.2%, and 92.3%, respectively. MIBG scan showed one false positive (neuroblastoma) and one false negative finding. There was one patient with positive MIBG scan and negative findings of the biochemical test, anatomic imaging. Conclusion: Our data suggest that I-123/I-131 MIBG scan has higher sensitivity, specificity, positive predictive value, negative predictive value and accuracy than those of biochemical test and anatomic imaging. Thus, we expect that MIBG scan is e tectively used for initial diagnosis of pheochromocytoma alone as well as biochemical test and anatomic imaging.