• 제목/요약/키워드: scan circuit

검색결과 118건 처리시간 0.034초

Load-Adaptive Address Energy Recovery Technique for Plasma Display Panel

  • 이준영
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2005년도 춘계 학술대회
    • /
    • pp.192-200
    • /
    • 2005
  • A high speed address recovery technique for AC plasma display panel(PDP) is proposed. By removing the GND switching operation, the recovery speed can be increased and switching loss due to GND switch also becomes to be reduced. The proposed method is able to perform load-adaptive operation by controlling the voltage level of energy recovery capacitor, which prevents increasing inefficient power consumption caused by circuit loss during recovery operation. Thus, th e technique shows the minimum address power consumption according to various displayed images, different from prior methods operating in fixed mode regardless of images. Test results with 50' HD single- scan PDP(resolution : $1366{\times}768$) show that less than 350ns of recovery time is successfully accomplished and about $54\%$ of the maximum power consumption can be reduced, tracing minimum power consumption curves.

  • PDF

Geometric calibration of a computed laminography system for high-magnification nondestructive test imaging

  • Chae, Seung-Hoon;Son, Kihong;Lee, Sooyeul
    • ETRI Journal
    • /
    • 제44권5호
    • /
    • pp.816-825
    • /
    • 2022
  • Nondestructive testing, which can monitor a product's interior without disassembly, is becoming increasingly essential for industrial inspection. Computed laminography (CL) is widely used in this application, as it can reconstruct a product, such as a printed circuit board, into a three-dimensional (3D) high-magnification image using X-rays. However, such high-magnification scanning environments can be affected by minute vibrations of the CL device, which can generate motion artifacts in the 3D reconstructed image. Since such vibrations are irregular, geometric corrections must be performed at every scan. In this paper, we propose a geometry calibration method that can correct the geometric information of CL scans based on the image without using geometry calibration phantoms. The proposed method compares the projection and digitally reconstructed radiography images to measure the geometric error. To validate the proposed method, we used both numerical phantom images at various magnifications and images obtained from real industrial CL equipment. The experiment results confirmed that sharpness and contrast-to-noise ratio (CNR) were improved.

DMD를 이용한 마스크리스 리소그래피 시스템의 고해상도 구현을 위한 다중 빔 에너지 분석에 관한 연구 (A Study on the Analysis of Multi-beam Energy for High Resolution with Maskless Lithography System Using DMD)

  • 김종수;신봉철;조용규;조명우;이수진
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.829-834
    • /
    • 2011
  • 고 집적 회로의 제작에 있어서 노광 공정은 가장 중요한 기술로 주로 마스크 방식의 노광 방법을 사용하지만 다품종 소량 생산 및 주기적인 제품 변화에 있어서 효율적이지 못하기 때문에 마스크리스 리소그래피 기술이 노광공정에서 각광받고 있다. 본 연구에서는 DMD를 이용한 마스크리스 리소그래피에 있어 다중 레이저 빔의 에너지와 중첩도와의 연관성을 시뮬레이션을 통해 분석하였다. 시뮬레이션을 통해 최적의 스캔 라인 간격을 제시하였고, LDI 시스템을 이용한 노광 실험을 통해 미세 페턴의 정밀도를 향상시킬 수 있었다.

자궁 재활치료를 위한 울트라-스캔 방식의 펄스형 레이저시스템 (Pulsed Laser System of Ultra-scan Way for Uterus Rehabilitation Treatment)

  • 김휘영
    • 한국콘텐츠학회논문지
    • /
    • 제9권6호
    • /
    • pp.256-265
    • /
    • 2009
  • 레이저 출력은 20w에서 100w까지 연속적으로 조절이 되고 노출시간은 0.01초에서 수초 사이로 조절이 가능 하다. 펄스동작은 레이저 빔을 주기적으로 차단할 수가 있고 슈퍼펄스는 0.1$\sim$1ms사이에서 방전을 이루어지며, 순간적인 레이저 출력은 5$\sim$10 까지 증가된다. 특히, 자궁암의 경우 자궁구 내벽에서 악성세포를 제거해야 하므로 펄스에 대한 튜브출력의 안정이 매우 중요하다. 따라서, 본 연구에서는 영전압 스위칭동작을 확보하여 컨버터 1 차측 주 회로에 고주파 변압기 누설인덕턴스($L_1$) 증가 및 직렬 인덕터 없이 안정된 소프트 스위칭 동작영역이 확보, 인덕터($L_f$)전류의 순환전류 경로차단 컨버터 1차측 주회로 스위칭소자와 고주파 변압기의 도통손실이 크게 줄어, 고주파 2차측 정류부($D_5,\;D_6$)도 소프트 스위칭 되고, 스위칭손실 흡수분을 부하로 회생할 수 있는 특징을 갖고, 튜브안정화가 되어 설계 및 제작하여 실험한 결과, 기존장비에 비해 10%의 향상된 결과를 가져왔고, 추후 시스템적으로 보완을 하면 우수한 결과가 될 것으로 사려 된다.

Dielectric 마스크 적용 UV 레이저 프로젝션 가공을 이용한 빌드업 필름 내 선폭 10μm급 패턴 가공 연구 (DPSS UV laser projection ablation of 10μm-wide patterns in a buildup film using a dielectric mask)

  • 손현기;박종식;정수정;신동식;최지연
    • 한국레이저가공학회지
    • /
    • 제16권3호
    • /
    • pp.27-31
    • /
    • 2013
  • To engrave high-density circuit-line patterns in IC substrates, we applied a projection ablation technique in which a dielectric ($ZrO_2/SiO_2$) mask, a DPSS UV laser instead of an excimer laser, a refractive beam shaping optics and a galvo scanner are used. The line/space dimension of line patterns of the dielectric mask is $10{\mu}m/10{\mu}m$. Using a ${\pi}$ -shaper and a square aperture, the Gaussian beam from the laser is shaped into a square flap-top beam; and a telecentric f-${\theta}$ lens focuses it to a $115{\mu}m{\times}105{\mu}m$ flat-top beam on the mask. The galvo scanner before the f-${\theta}$ lens moves the beam across the scan area of $40mm{\times}40mm$. An 1:1 projection lens was used. Experiments showed that the widths of the engraved patterns in a buildup film ranges from $8.1{\mu}m$ to $10.2{\mu}m$ and the depths from $8.8{\mu}m$ to $11.7{\mu}m$. Results indicates that it is required to increase the projection ratio to enhance profiles of the engraved patterns.

  • PDF

5.0 inch WVGA Top Emission AMOLED Display for PDA

  • Lee, Kwan-Hee;Ryu, Seoung-Yoon;Park, Sang-Il;Ryu, Do-Hyung;Kim, Hun;Song, Seung-Yong;Chung, Bo-Yong;Park, Yong-Sung;Kang, Tae-Wook;Kim, Sang-Chul;Cho, Yu-Sung;Park, Jin-Woo;Kwon, Jang-Hyuk;Chung, Ho-Kyoon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.7-10
    • /
    • 2003
  • Samsung SDI has developed a full color 5.0" WVGA AMOLED display with top emission and a super fine pitch of 0.1365mm(l86ppi), the world's highest resolution OLED display ever reported to date. Scan driver circuits and demux circuit were integrated into the display panel, using low temperature poly-Si TFT CMOS technology, and data driver circuit were mounted using COG chips. Peak luminescence was greater than 300cd/ $m^2$ with power consumption of 500mW with 30% of the pixels on illuminated.

  • PDF

MRI용 심전도/혈류 게이팅 시스템 설계 (Design of ECG/PPG Gating System in MRI Environment)

  • 장봉렬;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Oven Temperature Control by Integral - Cycle Binary Rate Modulation Technique

  • Tipsuwanporn, V.;Piyarat, W.;Chochai, N.;Jamjan, K.;Paraken, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.278-280
    • /
    • 1999
  • This paper proposes controlling of temperature in an oven by using 4 bits Integral - Cycle Binary Rate Modulation (IBRM) method and ac line with frequency 50 Hz. Microcontroller MCS-51 controls IBRM according to Proportional Integral controller (PI) function. Discrete signals are used in the system modeled by using Ziegler Nichols principle for analyzing the stability before designing the system. This procedure makes it easy to investigate system response. The system is implemented by 4 bits digital circuit which gives 320 patterns of ac signal fur controlling the generation of energy for 3,000 watts thermal coil every 20 ms of each cycle. We divide scan time (Ts$\sub$n/) in to 20 intervals, 1 ms interval is selected to generate 16 patterns IBRM. Because of this method gives the ripple lower than 2% it generates less noise fur system. Moreover, we can consider whole system from the time model of control procedure and IBRM algorithm at 40-200$^{\circ}C$ with ${\pm}$ 1$^{\circ}C$ error in the 1 cubic meter oven.

  • PDF

내장 메모리 테스트를 위한 BIST 회로 자동생성기 (Automatic BIST Circuit Generator for Embedded Memories)

  • 양선웅;장훈
    • 대한전자공학회논문지SD
    • /
    • 제38권10호
    • /
    • pp.746-753
    • /
    • 2001
  • 본 논문에서 구현한 GenBIST는 메모리 테스팅을 위한 정보를 입력으로 받아 테스트용 회로를 VerilogHDL 코드로 자동 생성해 주는 설계 자동화 툴 이다. 상용 툴 들을 포함한 기존의 툴 들은 대부분 메모리 테스트를 위한 알고리즘들을 라이브러리화하고 이를 회로로 생성해주는 방식인데 반해, 본 논문에서 구현한 툴은 사용자가 정의한 알고리즘대로 회로를 생성해 줌으로써 새로운 알고리즘의 적용을 용이하게 하였다. 또한 다중 메모리를 지원할 수 있게 함으로써 메모리 BIST 회로를 공유할 수 있게 하였고 serial interfaceing 기법을 사용함으로써 경계 주사 기법과 함께 사용될 경우 메모리 테스트를 위한 부가적인 핀을 필요로 않는다.

  • PDF

수종 아말감의 Anodic Polarization에 관한 연구 (A STUDY ON THE ANODIC POLARIZATION OF DENTAL AMALGAMS)

  • 엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.199-204
    • /
    • 1989
  • The purpose of this study was to observe the anodic polarization curve from 4 kinds of low copper amalgam (Fine cut alloy, Spheralloy, Aristalloy and Amalcap) and 4 kinds of high copper amalgam (Dispersalloy, Sybraloy Orosphere and Tytin) obtained by using the potentiostat. The specimen made as the direction of manufacturer was stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. The 0.9% saline solution was used as electrolyte in pH 6.8-7.0 at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.785$cm^2$ for each specimen. All potentials reported are with respect to Ag/AgCl eelctrode. The following results were obtained. 1. The corrosion potential of high copper amalgams was higher than one of low copper amalgams, and the current density of high copper amalgam was lower than one of low copper amalgams. 2. The low copper amalgams had the similar pattern of polarization curve, but the high copper amalgams had the different pattern one another. 3. The polarization curve of Orosphere amalgam which is the admixed type was similar to one of low copper amalgam.

  • PDF