• 제목/요약/키워드: scaler

검색결과 135건 처리시간 0.026초

치근면 활택술후 치질삭제와 표면형태변화에 관한 연구 (A Study on the Loss of Tooth Substance and Surface Changes following Root Planing)

  • 허수례;김수아;서석란;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제28권2호
    • /
    • pp.351-372
    • /
    • 1998
  • The purpose of this study was to evaluate in vitro effects of the loss of tooth substance and root surface changes following root planing with various periodontal instruments. The 39 extracted human teeth due to severe periodontal disease were included. The total 50 root surfaces of 30 teeth were root planed with following instruments : Group 1, with Gracey curette, Group 2, with ultrasonic scaler, Group 3, with rotating root planing bur, Group 4, with Gracey curette plus rubber cup polishing, and Group 5, with ultrasonic scaler plus rubber cup polishing. Following root planing, the amount of tooth substance loss was evaluated by measuring the weight of the removed tooth substance and then 5 specimens ($5{\times}5{\times}2mm$) were randomly selected from the each group for roughness measurement. Root planed areas of each specimen were subjected to five measurements using the Profilometer and an average surface roughness values(Ra) for each group was obtained. Statistical difference for roughness values of each group was analyzed using oneway ANOVA and student t-test. For scanning electron microscopic(SEM) examination of root surface changes following root planing, 15 root surfaces of remaining 9 teeth were root planed and 3 specimens were randomly selected. The mean loss of tooth substance removed was Group 1, $7.0{\pm}1.09mg$, Group 2, $1.3{\pm}1.00mg$, Group 3, $5.8{\pm}1.72mg$, Group 4, $8.7{\pm}1.34mg$, and Group 5, $4.5{\pm}1.68mg$ following root palning, respectively. These results indicate that curette is effective instrument in the respect of diseased root substance removal. The average surface roughness values are following results : Group 1 and Group 4 were the smoothest surface ($Ra=0.34{\pm}0.06{\mu}m$, $Ra=0.34{\pm}0.04{\mu}m$, respectively) and Group 2 was the roughest surface ($Ra=2.09{\pm}0.06{\mu}m$). Statistical analysis of roughness values demonstrated a highly significant difference (P<0.05) between each experimental groups. However, no statistically significant difference in roughness values were observed between the Group 1 and Group 4. The results in this study suggest that curette and/or polishing procedure should be done after root planing with ultrasonic scaler and caution should be used with dia-mond-coated bur during routine root planing procedure.

  • PDF

Air-Polisher의 응용법 (Application of Air-Polisher)

  • 김민정
    • 대한심미치과학회지
    • /
    • 제7권1호
    • /
    • pp.72-78
    • /
    • 1998
  • Recently, esthetic dentistry has been developed because beauty is pursued by both dentists and patients. A scope of esthetic treatment has been expanded and the roles of hygienists in dental treatment have also become of importance. Generally, we make use of the ultra-sonic scaler to remove the stains attached to teeth surfaces, but when we utilize the rubber cup and pumice in prophylaxis, this increases the hypersensitivity, patient's anxiety, and chairtime. So, we substitute Air-polishing that increases patient's satisfaction and decreases chairtime for above method, Here, I would like to explain indications and contraindications, advantages and disadvantages, and usages of Air-polilshing briefly.

  • PDF

현장 적용형 Mash seam 용접기의 개발 (Development of a Mash Seam Welder for the Factory Application)

  • 이왕하;박상국
    • 제어로봇시스템학회논문지
    • /
    • 제10권5호
    • /
    • pp.411-414
    • /
    • 2004
  • In this paper, a power controller and 3 phase voltage source inverter are proposed for the improvement of weldability of large scaler Mash seam welder. The welder system is designed for the low cost and the improvement of weldability. For this system, the thyristor convertor has performed constant current controlling in the output terminal by using PAM type inverter. We have simulated our algorithm and made a prototype welder for experiment. Through the experiment, we have confirmed the improvement of weldability of our system.

장애인 치과환자의 치면세균막 관리 (Dental biofilm control of the disabled patients)

  • 조현재
    • 대한치과의사협회지
    • /
    • 제56권8호
    • /
    • pp.432-436
    • /
    • 2018
  • Dental caries and periodontitis are the major concerns of oral disease to human, and its etiologic factor is dental biofilm. The aim of this study is to discuss the clinical application method and the meaning of dental biofilm control in the disabled patients. Generally, ultrasonic scaler are likely to generate excessive stimulus to the disabled patients. Rubber cup application using Ni-Ti engine could remove dental biofilm more comfortably to the disabled patients.

  • PDF

초고해상도 영상에 적합한 적응형 스케일러 (An adaptive scaler for UHD video)

  • 윤성준;한종기
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2015년도 하계학술대회
    • /
    • pp.173-176
    • /
    • 2015
  • 최근 고화질 영상의 수요가 증가함에 따라, UHD급 디스플레이의 디지털 기기가 등장하기 시작했다. 하지만 기존의 스케일러 모듈에 사용된 보간법들로는 기존의 저해상도의 영상 콘텐츠로부터 고품질의 영상을 획득하기가 어렵다. 따라서 본 논문에서는 고품질의 영상을 획득 가능한 초고해상도 영상에 적합한 스케일러를 제안한다.

  • PDF

Large Eddy Simulation of Turbulent Combustion Flow Based on 2-scaler flamelet approach

  • Oshima, Nobuyuki;Tominaga, Takuji
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.18-21
    • /
    • 2006
  • This paper investigates LES of turbulent combustion flow based on 2-scalar flamelet approach, where a G-equation and a conserved scalar equation simulate a propagation of premixed flame and a diffusion combustion process, respectively. The turbulent SGS modeling on these flamelet combustion approach is also researched. These LES models are applied to an industrial flows in a full scale gasturbine combustor with premixed and non-premixed flames. The numerical results predict the characteristics of experiment temperature profiles. Unsteady features of complex flames in combustor are also visualized.

  • PDF

유한요소 해석을 통한 치과용 초음파 Scaler의 설계 및 평가 (Design and Evaluation of Ultrasonic dental scaler produced for Finite Element Analysis)

  • 김철민;이영진;정영훈;백종후;강국진;이정배;이승대
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.20-20
    • /
    • 2009
  • 치아의 치석제거 및 치골절삭에 사용되는 초음파 스케일러는 일반적으로 마그넷형과 압전형으로 구분할 수 있으며, 최근에 들어 소형화, 저전력, 정밀성, 저비용 등의 장점으로 인해 압전형이 주로 사용되고 있다. 국내의 대부분의 치과에서 한 대 이상 운용되는 초음파 스케일러는 대부분 유럽 제품으로며, 국내에서는 이를 대체하기 위한 제품이 출시되고 있으나 아직까지 유럽 제품에 비해 출력강도, 정밀도 등에서 성능이 모자란 현실로 시장에서 외면 받고 있다. 본 연구에서는 앞서 언급한 압전 초음파 스케일러에 대한 체계적인 연구를 진행하여 외국에 비해 상대적으로 성능이 떨어지는 초음파 스케일러의 성능을 개선하고자 하였다. 이를 위하여 스케일러의 진동 발생부, 즉 압전 세라믹과 SUS 재질의 head, tail 부로 구성된 진동발생부의 최적구조톨 도출하기 위하여 유한요소 해석을 실시하였으며, 스케일러의 중심주파수 28kHz에서 최대 출력이 발생할 수 있는 구조를 도출하였다. 스케일러의 Head 와 Tail 부문의 두께와 직경, 길이 변화에 따른 중심주파수 및 출력 변위의 경향분석을 실시하였으며, 이상의 결과를 바탕으로 실제 스케일러를 제작하여 시뮬레이션의 유효성을 검증하였다. 이상의 과정으로 거쳐 개발된 압전 초음파 스케일러는 다양한 Tip 종류의 영향을 최소화할 수 있으며, 중심주파수는 28~30kHz 에서 뛰어난 성능을 나타내어 기종 유럽제품의 성능을 앞지르는 특성을 확보할 수 있었다.

  • PDF

Poly Phase Filter 기반의 영상 스케일러를 이용한 개선 된 정맥 영역 추출 방법 (Enhanced Vein Detection Method by Using Image Scaler Based on Poly Phase Filter)

  • 김희경;이승민;강봉순
    • 한국정보통신학회논문지
    • /
    • 제22권5호
    • /
    • pp.734-739
    • /
    • 2018
  • 생체 인식 방식 중 하나인 지문 인식과 홍채 인식 등은 태양광과 같은 외부 요소에 쉽게 영향을 받는다. 따라서 최근에는 생체 내부의 특징을 이용하는 방법으로 지정맥 인식을 이용하고 있다. 정확한 정맥 인식을 위해서는 정맥 영역과 배경 영역을 확실하게 분리하는 것이 중요하다. 하지만 입력 영상에 포함 된 불균일한 조명 성분의 영향으로 정맥 영역과 배경 영역을 분리하는 것이 어려웠기 때문에 입력 영상의 조명 성분을 정규화 시킨 후 정맥 영역과 배경 영역을 분리 할 수 있는 방법이 제안되었다. 본 논문에서는 기존의 조명 정규화 방법을 바탕으로 영상 스트레칭 과정이 포함 된 영상의 전처리 단계와 이진화, 레이블링 방법을 개선하여 기존의 정맥 인식 기법에 비해 더 나은 질적 개선을 이루고 처리 속도를 향상 시킬 수 있는 방법을 제안한다.

Influence of scaling procedures on the integrity of titanium nitride coated CAD/CAM abutments

  • Gehrke, Peter;Spanos, Emmanouil;Fischer, Carsten;Storck, Helmut;Tebbel, Florian;Duddeck, Dirk
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권3호
    • /
    • pp.197-204
    • /
    • 2018
  • PURPOSE. To determine the extent of treatment traces, the roughness depth, and the quantity of titanium nitride (TiN) removed from the surface of CAD/CAM abutments after treatment with various instruments. MATERIALS AND METHODS. Twelve TiN coated CAD/CAM abutments were investigated for an in vitro study. In the test group (9), each abutment surface was subjected twice (150 g vs. 200 g pressure) to standardized treatment in a simulated prophylaxis measure with the following instruments: acrylic scaler, titanium curette, and ultrasonic scaler with steel tip. Three abutments were used as control group. Average surface roughness (Sa) and developed interfacial area ratio (Sdr) of treated and untreated surfaces were measured with a profilometer. The extent of treatment traces were analyzed by scanning electron microscopy. RESULTS. Manipulation with ultrasonic scalers resulted in a significant increase of average surface roughness (Sa, P<.05) and developed interfacial area ratio (Sdr, P<.018). Variable contact pressure did not yield any statistically significant difference on Sa-values for all instruments (P=.8). Ultrasonic treatment resulted in pronounced surface traces and partially detachment of the TiN coating. While titanium curettes caused predominantly moderate treatment traces, no traces or detectable substance removal has been determined after manipulation with acrylic curettes. CONCLUSION. Inappropriate instruments during regular plaque control may have an adverse effect on the integrity of the TiN coating of CAD/CAM abutments. To prevent defects and an increased surface roughness at the transmucosal zone of TiN abutments, only acrylic scaling instruments can be recommended for regular maintenance care.

960MHz Quadrature LC VCO를 이용한 CMOS PLL 주파수 합성기 설계 (Design of a 960MHz CMOS PLL Frequency Synthesizer with Quadrature LC VCO)

  • 김신웅;김영식
    • 대한전자공학회논문지SD
    • /
    • 제46권7호
    • /
    • pp.61-67
    • /
    • 2009
  • 본 논문에서는 0.25-$\mu$m 디지털 CMOS공정으로 제작된 UHF대역 RFID를 위한 무선통신용 쿼드러처(Quadrature) 출력이 가능한 Integer-N방식의 PLL 주파수 합성기를 설계 및 제작하여 측정하였다. Integer-N 방식의 주파수 합성기의 주요 블록인 쿼드러처 전압제어 발진기(Voltage Controeld Oscillator, VCO)와 위상 주파수 검출기(Phase Frequency Detector, PFD), 차지 펌프(Charge Pump, CP)를 설계하고 제작하였다. 전압제어발진기는 우수한 위상노이즈 특성과 저전력 특성을 얻기 위해 LC 공진기를 사용하였으며 전압제어 가변 캐패시터는 P-channel MOSFET의 소스와 드레인 다이오드를 이용하여 설계되었으며 쿼드러처 출력을 위해 두 개의 전압제어발진기를 서로 90도 위상차를 가지도록 설계하였다. 주파수 분주기는 프리스케일러(Pre-scaler)와 아날로그 디바이스사의 칩 ADF4111을 사용하였으며 루프 필터는 3차 RC필터로 설계하여 측정하였다. 측정결과 주파수 합성기의 RF 출력 전력은 50옴 부하에서 -13dBm이고, 위상 잡음은 100KHz offset 주파수에서 -91.33dBc/Hz 이었으며, 동작 주파수영역은 최소 930MHz에서 최대 970MHz이고 고착시간은 약 600$\mu$s이다.