• 제목/요약/키워드: scaled down model

검색결과 127건 처리시간 0.034초

2차목 초음속 디퓨저의 주요 설계 변수에 따른 성능 특성 (Performance Characteristics of Secondary Throat Supersonic Exhaust Diffusers)

  • 박진호;전준수;유이상;고영성;김선진;김유;한영민
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.641-644
    • /
    • 2011
  • 축소형 2차목 초음속 디퓨저를 설계/제작하여 디퓨저 주요 설계 변수에 따른 성능 특성 변화를 파악하고자 한다. 디퓨저 주요 설계 변수로 디퓨저 입구 길이(Ld), 2차목 길이(Lst), 확산부 길이(Ls)를 선정하였고, 상온의 질소를 사용한 실험을 통하여 디퓨저 성능 특성을 파악하였다. 실험 결과 디퓨저 입구 길이에 따른 변화는 크게 없었으며, 2차목 길이, 확산부 길이에 따라서 시동압력의 영향이 있었고, 2차목 길이대 2차목 직경비(Lst/Dst)가 8 이상에서는 시동압력의 변화가 없는 것으로 확인되었다.

  • PDF

Study on seismic strengthening of railway bridge pier with CFRP and concrete jackets

  • Ding, Mingbo;Chen, Xingchong;Zhang, Xiyin;Liu, Zhengnan;Lu, Jinghua
    • Earthquakes and Structures
    • /
    • 제15권3호
    • /
    • pp.275-283
    • /
    • 2018
  • Seismic strengthening is essential for existing bridge piers which are deficient to resist the earthquake. The concrete and CFRP jackets with a bottom-anchoring method are used to strengthen railway bridge piers with low reinforcement ratio. Quasi-static tests of scaled down model piers are performed to evaluate the seismic performance of the original and strengthened bridge pier. The fracture characteristics indicate that the vulnerable position of the railway bridge pier with low reinforcement ratio during earthquake is the pier-footing region and shows flexural failure mode. The force-displacement relationships show that the two strengthening techniques using CFRP and concrete jackets can both provide a significant improvement in load-carrying capacity for railway bridge piers with low reinforcement ratio. It is clear that the bottom-anchoring method by using planted steel bars can guarantee the CFRP and concrete jackets to work jointly with original concrete piers Furthermore, it can be found that the use of CFRP jacket offers advantages over concrete jacket in improving the energy dissipation capacity under lateral cyclic loading. Therefore, the seismic strengthening techniques by the use of CFRP and concrete jackets provide alternative choices for the large numbers of existing railway bridge piers with low reinforcement ratio in China.

보증 클레임 시계열 데이터를 위한 퍼지 PID 제어 (Fuzzy PID Control of Warranty Claims Time Series)

  • 이상현;이상준;문경일;조성의
    • 한국IT서비스학회지
    • /
    • 제8권4호
    • /
    • pp.175-185
    • /
    • 2009
  • Objectifying claims filed during the warranty period, analyzing the current circumstances and improving on the problem in question is an activity worth doing that could reduce the likelihood of claims to occur, cut down on the costs, and enhance the corporate image of the manufacturer. Existing analyses of claims are confronted with two problems. First, you can't precisely assess the risks of claims involved by means of the value of claims per 100 products alone. Second, even in a normal state, the existing approach fails to capture the probabilistic conflicts that escape the upper control limit of claims, thus leading to wrong control activities. To solve the first problem, this paper proposed that a time series detection concept where the claim rate is monitored based on the date when problems are processed and a hazard function for expression of the claim rate be utilized. For the second problem, this paper designed a model whereby to define a normal state by making use of PID (Proportion, Integral, Differential) and infer by way of a fuzzy concept. This paper confirmed the validity and applicability of the proposed approach by applying methods suggested in the actual past data of warranty claims of a large-scaled automotive firm, unlike hypothetical simulation data, in order to apply them directly in industrial job sites, as well as making theoretical suggestions for analysis of claims.

Effects of Isolation Period Difference and Beam-Column Stiffness Ratio on the Dynamic Response of Reinforced Concrete Buildings

  • Chun, Young-Soo;Hur, Moo-Won
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권4호
    • /
    • pp.439-451
    • /
    • 2015
  • This study analyzed the isolation effect for a 15-story reinforced concrete (RC) building with regard to changes in the beam-column stiffness ratio and the difference in the vibration period between the superstructure and an isolation layer in order to provide basic data that are needed to devise a framework for the design of isolated RC buildings. First, this analytical study proposes to design RC building frames by securing an isolation period that is at least 2.5 times longer than the natural vibration period of a superstructure and configuring a target isolation period that is 3.0 s or longer. To verify the proposed plan, shaking table tests were conducted on a scaled-down model of 15-story RC building installed with laminated rubber bearings. The experimental results indicate that the tested isolated structure, which complied with the proposed conditions, exhibited an almost constant response distribution, verifying that the behavior of the structure improved in terms of usability. The RC building's response to inter-story drift (which causes structural damage) was reduced by about one-third that of a non-isolated structure, thereby confirming that the safety of such a superstructure can be achieved through the building's improved seismic performance.

Validation of the numerical simulations of flow around a scaled-down turbine using experimental data from wind tunnel

  • Siddiqui, M. Salman;Rasheed, Adil;Kvamsdal, Trond
    • Wind and Structures
    • /
    • 제29권6호
    • /
    • pp.405-416
    • /
    • 2019
  • Aerodynamic characteristic of a small scale wind turbine under the influence of an incoming uniform wind field is studied using k-ω Shear Stress Transport turbulence model. Firstly, the lift and drag characteristics of the blade section consisting of S826 airfoil is studied using 2D simulations at a Reynolds number of 1×105. After that, the full turbine including the rotational effects of the blade is simulated using Multiple Reference Frames (MRF) and Sliding Mesh Interface (SMI) numerical techniques. The differences between the two techniques are quantified. It is then followed by a detailed comparison of the turbine's power/thrust output and the associated wake development at three tip speeds ratios (λ = 3, 6, 10). The phenomenon of blockage effect and spatial features of the flow are explained and linked to the turbines power output. Validation of wake profiles patterns at multiple locations downstream is also performed at each λ. The present work aims to evaluate the potential of the numerical methods in reproducing wind tunnel experimental results such that the method can be applied to full-scale turbines operating under realistic conditions in which observation data is scarce or lacking.

Experiments and MAAP4 Assessment for Core Mixture Level Depletion After Safety Injection Failure During Long-Term Cooling of a Cold Leg LB-LOCA

  • Kim, Y. S.;B. U. Bae;Park, G. C.;K. Y. Sub;Lee, U. C .
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.91-107
    • /
    • 2003
  • Since DBA(Design Basis Accidents) has been studied rather separately from SA(Severe Accidents) in the conventional nuclear reactor safety analysis, the thermal hydraulics during transition between DBA and SA has not been identified so much as each accident itself. Thus, in this study, the thermal hydraulic behavior from DBA to the commencement of SA has been experimentally and analytically investigated for the long-term cooling phase of LB-LOCA(Large-Break Loss-of-Coolant Accident). Experiments were conducted for both cases of the loop seal open and closed in an integral test loop, named as SNUF (Seoul National University Facility), which was scaled down to l/6.4 in length and 1/178 in area of the APR1400 (Advanced Power Reactor 1400MWe). The core mixture level was a main measured value since it took major role in the fuel heat-up rate, the location of fuel melting initiation and the channel blockage by melting material during SA. Experimental results were compared to MAAP4.03 to assess its model of calculating the core mixture level. MAAP4.03 overestimates the core two- phase mixture level because sweep-out and spill-over and the measures to simulate the status of loop seal are not included, which is against the conservatism. Thus, it is recommended that MAAP4.03 should be improved to simulate the thermal hydraulic phenomena, such as sweep-out, spill-over and the status of loop seal.

A Hierarchical Model Predictive Voltage Control for NPC/H-Bridge Converters with a Reduced Computational Burden

  • Gong, Zheng;Dai, Peng;Wu, Xiaojie;Deng, Fujin;Liu, Dong;Chen, Zhe
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.136-148
    • /
    • 2017
  • In recent years, voltage source multilevel converters are very popular in medium/high-voltage industrial applications, among which the NPC/H-Bridge converter is a popular solution to the medium/high-voltage drive systems. The conventional finite control set model predictive control (FCS-MPC) strategy is not practical for multilevel converters due to their substantial calculation requirements, especially under high number of voltage levels. To solve this problem, a hierarchical model predictive voltage control (HMPVC) strategy with referring to the implementation of g-h coordinate space vector modulation (SVM) is proposed. By the hierarchical structure of different cost functions, load currents can be controlled well and common mode voltage can be maintained at low values. The proposed strategy could be easily expanded to the systems with high number of voltage levels while the amount of required calculation is significantly reduced and the advantages of the conventional FCS-MPC strategy are reserved. In addition, a HMPVC-based field oriented control scheme is applied to a drive system with the NPC/H-Bridge converter. Both steady-state and transient performances are evaluated by simulations and experiments with a down-scaled NPC/H-Bridge converter prototype under various conditions, which validate the proposed HMPVC strategy.

측방향흐름이 있는 만곡부 흐름의 해석

  • 박재현;윤성용;선우중호
    • 물과 미래
    • /
    • 제25권3호
    • /
    • pp.87-96
    • /
    • 1992
  • 측류취소로와 만곡부가 있는 원형수로를 1:20으로 축척한 모형수로에 대해 수리모형실험을 수행하여 만곡부에서의 유속, 수위와 유황과 같은 수리학적 특성을 살펴보고, 측류취소로가 만곡부에 미치는 영향을 살펴보고자 한다. 또한 모형수로에 대해 ADI방법으로 천수방정식을 수치해석하여 얻은 만곡부에서의 수리학적 특성을 실험에 의한 것과 비교하여 사용된 수치기법을 검증하였다. 대상이 된 전영역에 대하여 수리모형실험에서 얻어진 유속, 수위와 유황은 수치해석한 결과와 잘 일치한다. 그러나 직각좌표계를 사용함으로서 상대적으로 만곡부에서 단면축소 효과가 발생하므로 수치해석으로 얻어진 유속은 만곡부에서 실험치보다 약간 크게 나타나는데, 이것은 격자간격을 줄이면 개선되리라 판단된다. 수리모형실험과 수치해석 모두 만곡부 외측의 수위가 상승하고 내측의 유속이 빨라지는 만곡부의 특성을 잘 모사하고 있다. 만곡부 직전에 측류취수로가 있을 경우 측류취수로의 영향이 만곡수로내까지 미침을 알 수 있었다.

  • PDF

IRWST 환형관 실험장치 내의 수소화염 가속현상에 대한 CFD 해석 연구 (CFD ANALYSIS FOR HYDROGEN FLAME ACCELERATION IN THE IRWST ANNULUS TEST FACILITY)

  • 강형석;하광순;김상백;홍성완
    • 한국전산유체공학회지
    • /
    • 제17권3호
    • /
    • pp.75-86
    • /
    • 2012
  • We developed a preliminary CFD analysis methodology to predict a pressure build up due to hydrogen flame acceleration in the APR1400 IRWST on the basis of CFD analysis results for test data of hydrogen flame acceleration in a scaled-down test facility performed by Korea Atomic Energy Research Institute. We found out that ANSYS CFX-13 with a combustion model of the so-called turbulent flame closure and a model constant of A = 5.0, a grid model with a hexahedral cell length of 5.0 mm, and a time step size of $1.0{\times}10^{-5}$ s can be a useful tool to predict the pressure build up due to the hydrogen flame acceleration in the test results. Through the comparison of the simulated results with the test results, we found out that the proposed CFD analysis methodology enables us to predict the peak pressure within an error range of about ${\pm}29%$ for the hydrogen concentration of 19.5%. However, the error ranges of the peak pressure for the hydrogen concentration of 15.4% and 18.6% were about 66% and 51%, respectively. To reduce the error ranges in case of the hydrogen concentration of 15.4% and 18.6%, some uncertainties of the test conditions should be clarified. In addition, an investigation for a possibility of flame extinction in the test results should be performed.

건축물 IoT 센서 데이터를 분석하여 인공지능을 활용한 건축물 실시간 상태감시 및 예측 시스템 (By Analyzing the IoT Sensor Data of the Building, using Artificial Intelligence, Real-time Status Monitoring and Prediction System for buildings)

  • 서지민;김정집;권은혜;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 추계학술대회
    • /
    • pp.533-535
    • /
    • 2021
  • 본 연구가 기존 연구와 구별되는 점은 다음과 같다. 첫째, IoT 기술을 활용하여 클라우드 기반으로 시스템을 구축함으로써 인터넷 연결이 되는 어느 곳에서나 건축물의 상태를 실시간으로 모니터링 할 수 있도록 시스템을 구축했다는 것이다. 둘째, 계측된 시계열 센서 데이터를 인공지능(LSTM)과 통계적(ARIMA) 방법을 이용하여 미래를 예측하는 모델을 개발하고 제안한 예측 모델의 실효성을 건축물 축소모형을 이용하여 실험적으로 검증하였다. 셋째, 또한 다수의 센서 데이터를 융합하여 건축물의 구조적 변형을 시각화함으로써 보다 입체적으로 건축물을 상태를 분석하는 방법에 대해 제안하고 실제 지진피해 건축물 사례를 통해 제안한 방법의 효용성을 입증하였다.

  • PDF