• Title/Summary/Keyword: scale down

Search Result 840, Processing Time 0.012 seconds

Bearing Capacity Evaluation of the Drilled Shaft Using Small Scale Model Test (축소모형말뚝을 이용한 현장타설말뚝의 지지력 평가)

  • 조천환;김홍묵;김웅규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.5
    • /
    • pp.117-126
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method. However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. A small scale test pile can be an alternative as a quality assurance for the drilled shaft with hish capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

An Dredging Depth Calculation of a Pile Under Lateral Loading Based on Model Test (모형실험을 통한 횡하중을 받는 말뚝의 준설깊이 산정)

  • Yoo, Chan-Ho;Lee, Jung-Jae;Kim, Seung-Wook;Chung, Jong-Min;Kim, Hong-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1094-1103
    • /
    • 2010
  • The safety of pile foundation is getting declined when the pile foundation acting on lateral load is exposed by dredging. So appropriate reinforcement is needed for stability secure. Thus, in this study, the stability variation and reinforcement range caused by dredging is estimated on the basis of down scale test. The scale effect is determined by real scale numerical analysis. the behavior of pile by dredging stages is estimated by load control type. The credibility is verified through the comparison between down scale model test and numerical analysis.

  • PDF

Design of A scale-down experimental model for SFR reactor vault cooling system performance analyses

  • Kim, Koung Moon;Hwang, Ji-Hwan;Wongwises, Somchai;Jerng, Dong-Wook;Ahn, Ho Seon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1611-1625
    • /
    • 2020
  • We propose a scaled-down experimental model of vertical air-natural convection channels by applying the modified Ishii-Kataoka scaling method with the assistance of numerical analyses to the Reactor Vault Cooling System (RVCS) of the Proto-type Gen-IV Sodium-cooled fast reactor (PGSFR) being developed in Korea. Two major non-dimensional numbers (modified Richardson and Friction number) from the momentum equation and Stanton number from the energy balance equation were identified to design the scaled-down experimental model to assimilate thermal-hydraulic behaviors of the natural convective air-cooling channel of RVCS. The ratios of the design parameters in the PGSFR RVCS between the prototype and the scaled-down model were determined by setting Richardson and Stanton number to be unity. The friction number which cannot be determined by the Ishii-Kataoka method was estimated by numerical analyses using the MARS-KS system code. The numerical analyses showed that the friction number with the form loss coefficient of 2.0 in the scale-down model would result in an acceptable prediction of the thermal-hydraulic behavior in RVCS. We also performed experimental benchmarking using the scaled-down model with the MARS-KS simulations to verify the appropriateness of the scale-down model, which demonstrated that the temperature rises and the average air flow velocity measured in the scale-down model.

Simplified Load Calculation and Structural Test for Scale Down Model of Small Wind Turbine Blade according to IEC 61400-2 (IEC 61400-2에 의거한 소형 풍력발전용 블레이드 축소모델의 단순 하중 계산 및 구조 시험)

  • Jang, Yun-Jung;Kang, Ki-Weon
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.3
    • /
    • pp.1-5
    • /
    • 2013
  • This study deals with simplified load calculation and structural testing for scale down model of small wind turbine blade. First, the blade was designed and produced scale down to 0.2 ratio of initial blade. And moments were acquired by simplified load calculation equations according to IEC 61400-2 standard. Also, structural test using weight was conducted to obtain the maximum moment. Therefore maximum moments were compared at calculation and test.

Bearing Capacity Evaluation of Drilled Shaft for Top & Down Method (탑다운 기초 현장타설말뚝의 지지력 평가)

  • Cho, Chun-Whan;Kim, Hong-Mook;Kim, Woong-Kyu;Kwon, Se-Oh;Sung, Byung-Wan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.58-65
    • /
    • 2004
  • Recently, the top & down method with drilled shafts as a foundation of high rise building is often adopted for the purpose of construction period reduction and construction cost effectiveness. It is common to omit the loading test as a Quality assurance on account of the high capacity of drilled shafts for the top & down method. It seems that the capacity of drilled shaft in recent top & down method is beyond that of conventional loading test method.However, the quality assurance for the drilled shaft as foundation of high rise building becomes much more important since the drilled shaft should bear much higher working load. It may be a small scale test pile could be an alternative as a quality assurance for the drilled shaft with high capacities. Through a case study, this paper gives an idea for solving the limitation of the conventional loading test method for the quality assurance of drilled shaft with high capacities. In particular, this paper analyzed the scale effect for a small drilled shaft installed into bedrock, which could be used for an alternative.

  • PDF

Azimuth Accuracy Test of Phase Comparison Direction Finding Method Using F-16 Fighter Scale-down Model (F-16 전투기 축소모델을 사용한 위상비교 방향 탐지 기법의 방위각 정확도 시험)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Young-Ho;Kim, Kichul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • This paper describes the azimuth accuracy test of phase comparison direction finding method using F-16 fighter scale-down model. When the antennas are placed on the bottom of a fighter, reflection signals caused by an aircraft structure arises and an azimuth error occurs. In this research, the F-16 fighter scale-down model was made to 5:1, and five antennas were placed on the bottom of the model, then the radio waves of emitters were received by the antennas in the $0-360^{\circ}$ azimuth angles. The accuracy test was performed by numerically analyzing the phases of the radio waves received by the five antennas. The azimuth error of the phase comparison direction finding with scale-down model was measured to be less than $0.5^{\circ}$ when the signal noise ratio was larger then 0dB, and it could be very useful for the design of the phase comparison direction finding method of the fighter.

A Study on the Performance Prediction and Evaluation of Scale Down Noise Reducing Device on the Top of Noise Barrier (축소모형 방음벽 상단장치의 성능예측 및 평가에 관한 연구)

  • Yoon, Je-Won;Kim, Young-Chan;Jang, Kang-Seok;Hong, Byung-Kook
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2844-2851
    • /
    • 2011
  • The purpose of this study is to set up an acoustic prediction technique and to perform the IL test of scale down noise reducing device for the development of the noise reducing device as the development of 400km/h class high speed train. First of all, the IL prediction of noise reducing device was performed with the 2D BEM method. And the noise test of scale down noise reducing device in anechoic chamber was performed for the verification of acoustic prediction technique and IL performance evaluation. As the results, the acoustic prediction technique for the development of noise reducing device was verified because the averaged IL difference between prediction and test is in 2dB(A). And the measured IL value of noise reducing device is less than 2dB(A), and additional IL with polyester absorption material is increased about 0.5dB(A).

  • PDF

A Study on the Memory Characteristics of MONOS Structure for the Scale-down EEPROM (Scale-down EEPROM을 위한 MONOS 구조의 기억특성에 관한 연굴)

  • 이상배;김주열;이상은;김선주;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.127-129
    • /
    • 1994
  • For scale-down EEPROM, MONOS structures with the different thicknesses of gate insulators, are fabricated and the memory characteristics, such as swtching and retention characteristics are investigated. As a results, the devices with the top oxide of 20A thick were deteriorated in retentivity. However, 11V-programmable voltage for ΔV$\sub$FB/=4V and 10-year data retention were achieved in MONOS structure with the t7p oxide of 50 ${\AA}$ thick and nitride 45${\AA}$thick.

  • PDF

The Effect of Oxide Layer Thickness to the Scale Defects Generation during Hot finish Rolling (열연사상 압연시 스케일 결함발생에 미치는 산화피막 두께의 영향)

  • 민경준
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.412-422
    • /
    • 1999
  • Scale defects generated on the strip surface in a tandem finishing mill line are collected from the strip trapped among the production mills by freezing the growing scale on the strip by the melt glass coating and shutting down the line simultaneously. The samples observed of its cross sectional figure showed the process of scale defect formation where the defects are formed at the base metal surface by thicker oxidized scale during each rolling passes. The properties of the oxidized layer growth both at rolling and inter-rolling are detected down sized rolling test simulating carefully the rolling condition of the production line. The thickness of the oxidized layer at each rolling pass are simulated numerically. The critical scale thickness to avoid the defect formation is determined through the expression of mutual relation between oxidized layer thickness and the lanks of the strip called quality for the scale defects. The scale growth of scale less than the critical thickness and also to keep the bulk temperature tuning the water flow rate and cooling time appropriately. Two units of Inerstand Cooler are designed and settled among the first three stands in the production line. Two units of scale defect is counted from the recoiled strip and the results showed distinct decrease of the defects comparing to the conventionaly rolled products.

  • PDF

Enhancing the Narrow-down Approach to Large-scale Hierarchical Text Classification with Category Path Information

  • Oh, Heung-Seon;Jung, Yuchul
    • Journal of Information Science Theory and Practice
    • /
    • v.5 no.3
    • /
    • pp.31-47
    • /
    • 2017
  • The narrow-down approach, separately composed of search and classification stages, is an effective way of dealing with large-scale hierarchical text classification. Recent approaches introduce methods of incorporating global, local, and path information extracted from web taxonomies in the classification stage. Meanwhile, in the case of utilizing path information, there have been few efforts to address existing limitations and develop more sophisticated methods. In this paper, we propose an expansion method to effectively exploit category path information based on the observation that the existing method is exposed to a term mismatch problem and low discrimination power due to insufficient path information. The key idea of our method is to utilize relevant information not presented on category paths by adding more useful words. We evaluate the effectiveness of our method on state-of-the art narrow-down methods and report the results with in-depth analysis.