• 제목/요약/키워드: saturation condition

검색결과 458건 처리시간 0.032초

전기자동차 구동용 모터를 위한 전류 제어 기술 (An Overview: Current Control Technique for Propulsion Motor for EV)

  • 이희광;남광희
    • 전력전자학회논문지
    • /
    • 제21권5호
    • /
    • pp.388-395
    • /
    • 2016
  • Electric vehicles (EV) and hybrid EVs (HEV) are designed and manufactured by GM, Toyota, Honda, and Hyundai motors. The propulsion system design process for EV requires integrating subsystem designs into an overall system model to maximize the performance of a given propulsion architecture. Therefore, high-power density and high-torque density are important attributes required for EV applications. To improve torque and power density, propulsion motors are designed for saturation during high-torque operation. The nonlinearity associated with core saturation is modeled by incorporating the cross-coupling inductances, which also behave nonlinearly. Furthermore, in EV environments, the battery is directly connected to the DC link, and the battery changes depending on the state of charge. It will be onerous if as many optimal current commands as different $V_{dc}$ were made. This paper presents the optimal current commands in the various operating condition and the current control technique in EV environments.

천층(淺層) 산사태(山沙汰) 발생에서의 물리 모델의 적용 (Application of a Physically Based Model to Shallow landsliding)

  • 김재수;김남춘;이헌호
    • 한국환경복원기술학회지
    • /
    • 제3권1호
    • /
    • pp.62-69
    • /
    • 2000
  • Topography influences shallow landslide initiation through both concentration of subsurface flow and the gradient on slope stability. A model for the topographic influence on shallow landslide initiation developed by Mongomerry et al (1994) is applied to 24 places with similar terrain and subsurface flow. The criterion of landslide prone areas developed by Korea Forestry Administration (1998) is likely to misinterpreted under the condition of heavy rainfall. Soil saturation can be predicted by this model. This relative soil saturation can be used to analyze the stability of each topographic point in the case of cohesionless soils with spatially constant thickness and saturated conductivity. The three different stages of steady state rainfall predicting to cause instability in each topographic points provide a good measure of shallow landsliding possibility.

  • PDF

상수도관로의 부식 방지를 위한 수돗물의 침식성 평가 (Evaluation on the Aggressivity of Drinking Water for Corrosion Control in Water Distribution System)

  • 곽필재;이현동;남상호
    • 상하수도학회지
    • /
    • 제11권1호
    • /
    • pp.53-63
    • /
    • 1997
  • The corrosion problems in water distribution system are reduced by decreasing the agressivity of drinking water which is evaluated by marble test and saturation indices(LSI or CCPP etc.). Marble test is a reliable method to determine the actual saturation condition of treated water. This study was done to determined the aggressivity of tap water and the effectiveness of $Ca(OH)_2$ and NaOH dosage for corrosion control. The drinking water in Seoul were evaluated by marble test and Langelier Index(LSI) and Calcium Carbonate Precipitation Potential(CCPP). The results indicated that the drinking water in Seoul were undersaturated as Calcium Carbonate($CaCO_3$). The LSI and CCPP of the water treated with $Ca(OH)_2$ were higher than that of water treated with NaOH. Therefore, to increase the Alkalinity and Calcium Hardness for corrosion control in water distribution system, $Ca(OH)_2$ is more effective than NaOH.

  • PDF

다중 제어기 및 다중 루우프로 구성된 포화 제어 시스템의 정적 리셋 와인드엎 방지 방법 (Static anti-reset windup method for saturating control systems with multiple controllers and multiloop configuration)

  • 박종구;최종호
    • 제어로봇시스템학회논문지
    • /
    • 제2권4호
    • /
    • pp.248-256
    • /
    • 1996
  • This paper presents an anti-reset windup (ARW) compensation method for saturating control systems with multiple controllers and/or multiloop configuration. The proposed ARW method is motivated by the concept of equilibrium point. The design parameters of the ARW scheme is derive explicitly by minimizing a reasonable performance index. In the event of saturation, the resulting dynamics of the compensated controller reflects the dynamics of the linear closed-loop system. The proposed method guarantees the total stability o fthe resulting control systems under a certain condition. An illustrative example is given to show the effectiveness of the proposed method. The paper is an extension of the results in Park and Choi[10].

  • PDF

미세채널형 증발열교환기의 성능에 관한 해석적 연구 (An Analytical Study on a Performance Estimation of an Evaporative Heat Exchanger having Mini Channel)

  • 유영준;민성기;최상민
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.233-236
    • /
    • 2012
  • In order to estimate the efficiency of an evaporative heat exchanger having mini channel, the equations to calculate heat exchanger properties, those are air temperatures and water temperatures etc, are derived from the governing equations based on the Navier-Stokes equation, even though there are several assumptions to make problem simplify. There are three heat transfer zones at the mini channel heat exchanger depending on the water condition. So, there are three governing equations and solutions to calculate the properties. As a results of this study, the equations to calculate a saturation point and a dry point are derived to evaluate an evaporative heat exchanger having micro channel. It is supposed to predict the performance and evaluate a mini channel heat exchanger.

  • PDF

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

고압계통 변류기 동작 특성 검토 (A Study on Performance of Current Transformer in High Voltage System)

  • 최기열;이덕수;박문빈;김희택;장기풍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

Design and Analysis of Interior Permanent Magnet Synchronous Motor Considering Saturated Rotor Bridge using Equivalent Magnetic Circuit

  • Shin, Kyung-Hun;Yu, Ju-Seong;Choi, Jang-Young;Cho, Han-Wook
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.404-410
    • /
    • 2014
  • This paper considers the design and performance evaluation of interior permanent magnet synchronous motors (IPMSMs). The initial design such as the sizing and shape design of the stator and rotor is performed for a given load condition. In particular, the equivalent magnetic circuit (EMC) is employed both to design the mechanical parameters of the rotor while considering nonlinear magnetic saturation effect and to analyze the magnetic characteristics of the air-gap of the motor. The designed motor is manufactured and tested to confirm the validity of the design processes and simulated results.

자기정렬 이중 리쎄스 공정에 의한 전력 MESFET 소자의 제작 (Power MESFETs Fabricated using a Self-Aligned and Double Recessed Gate Process)

  • 이종람;김도진;윤광준;이성재;강진영;이용탁
    • 전자공학회논문지A
    • /
    • 제29A권2호
    • /
    • pp.77-79
    • /
    • 1992
  • We propose a self-aligned and double recessed technique for GaAs power MESFETs application. The gate length and the wide recess width are defined by a selective removal of the SiN layer using reactive ion etching(RIE) while the depth of the channel is defined by chemical etching of GaAs layers. The threshold voltages and the saturation drain voltage could be sucessfully controlled using this technique. The lateral-etched distance increases with the dry etching time and the source-drain breakdown voltage of MESFET increases up to about 30V at a pinch-off condition. The electrical characteristics of a MESFET with a gate length of 2 x10S0-6Tm and a source-gate spacing of 33 x10S0-6Tm show maximum transconductance of 120 mS/mm and saturation drain current density of 170-190mA/mm at a gate voltage of 0.8V.

  • PDF

Finite Element Analysis of Electrical Double Layers near Triple Contact Lines

  • Kang Kwan Hyoung;Kang In Seok;Lee Choung Mook
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.491-494
    • /
    • 2002
  • To assess the electrostatic interaction of surfaces at the triple contact line, the electrostatic field is analyzed by using the finite element method. The Helmholtz free energy is used as a functional which should be minimized under an equilibrium condition. The numerical results are compared with the nonlinear analytical solution for a two-dimensional charged interface and linear solution for a wedge shaped geometry, which shows fairly good agreement. The method is applied to the analysis of electrostatic influence on the contact angle on a charged substrate. The excess free energy found to increase drastically as the contact angle approaches to zero. This excess free energy Plays an opposite role to the Primary electrocapillary effect, as the contact angle gets smaller. This enables an alternative explanation for the contact-angle saturation phenomenon occurring in electrical control of surface tension and contact angle.

  • PDF