• Title/Summary/Keyword: sanitary treatment

Search Result 318, Processing Time 0.033 seconds

Effects of Macrophytes on Biological Treatment of Processed-Leachate from Sanitary Landfill Sites

  • Kim, In-Sung;Choi, Hong-Keun;Lee, Eun-Ju
    • Journal of Ecology and Environment
    • /
    • v.29 no.1
    • /
    • pp.29-34
    • /
    • 2006
  • Three macrophytes species, that are, Phragmites australis, Zizania latifolia and Typha angustifolia were grown in mono culture in order to compare growth (relative biomass increase rate), variation of photosynthetic pigment (total chlorophyll, Chl a, Chl b and Chl a/Chl b) and effectiveness of nutriment removal in 15%o NaCl-salt solution or processed-leachate (salinity 19.6%o) from sanitary landfill sites. The relative biomass increase rate of p. australis was significantly higher than Z. latifolia and T. angustifolia. In the case of processed-leachate treatment, the relative biomass increase rates of above-part, rhizome and root of P. australiswere 178 %, 148 % and 157 %, respectively. Also, in 15%o NaCl-salt solution treatment, the relative biomass increase rates of P. australis increased as follows; 161 % (above-part), 183 % (rhizome) and 112 % (root). Total chlorophyll contents increased significantly in the leaves of P. australis and Z. latifolia grown in 15%o NaCl-salt solution and processed-leachate. Among three macrophytes, P. australis was evaluated as most effective macrophyte for the biological retreatment of processed-leachate from sanitary landfill sites.

Study on the Improvement of Water Regeneration Center by Using Non-water-soluble Sanitary Products: Focusing on the case of Seoul City (비수용성 위생용품 사용에 따른 물재생센터 개선방안: 서울시를 중심으로)

  • Choong-Gon Kim;Yoon-Hwan Bae;Hyun-Gon Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.39-44
    • /
    • 2023
  • This study was conducted to analyze problems related to non-water-soluble sanitary products during the treatment of water regeneration centers in E.T.F. and S.T.F. at a time when the demand and supply of non-water-soluble sanitary products are increasing. As a result, the improvement plan of the W.R.C. should focus on pretreatment facilities. When replacing facilities in the future, various dust removers suitable for the facility's reality will be installed in the pretreatment of S.T.F., and it is proposed to link a bar-racks screen with a comprehensive treatment device or install a comprehensive treatment device for impurities alone in the pretreatment of E.T.F.. In addition, a microscreen screen must be installed on the front end of the excretory treatment unit. to separate non-water-soluble materials, and it is necessary to secure a maintenance space for the excretory treatment unit.

Effect of Water-Hardness in the Biological Wastewater-treatment (생물학적 폐수처리시 수질 경도에 따른 처리효과 연구)

  • Park Young G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.58-64
    • /
    • 2004
  • Biological treatment of wastewater was studied with a purpose to remove TOC by the reduction of water hardness. The optimal conditions of coagulant were determined by reaction time and amount of coagulant. Experimental results indicate that the biological treatment after physico-chemical treatment was found to provide very efficient removal efficiency in the process to treat the textile wastewater, including the carbon dioxide treatment. The combined process of carbonization in the physico-chemical treatment respectively was increased the removal efficiencies of $30.0\%$ in biological treatment in comparison with exclusive biological treatment. As a result, the treatment of hardness after carbonization had the best removal efficiency of approximately $60.0\%$. The removal efficiencies in the exclusive biological treatment using Bacillus subtilis and after carbonization were increased by $38.9\%\;and\;69.0\%$ respectively. The combined Bacillus subtilis-assisted biological treatment was determined to be the most effective method to treat the textile wastewater in an economic point of view, the water quality in the wastewater treatment plays an important role.

Characterization of Photosynthetic Bacteria in Swine Wastewater (양돈 계수에서 광합성 미생물의 특성)

  • 최경민;양재경
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.28-33
    • /
    • 2001
  • Photosynthetic bacteria (PSB), strains IP-4 and IP-6-7 were isolated from nature, and were studied for swine wastewater treatment. It was confirmed that these PSB were very effective for the COD treatment. Growth of those PSB were increased to 4.5 fold in organic-acids (acetate, propionate and butyrate) added medium than cultivation in Lascelles basal medium and the amount of bacteriochlorophyll a were increased to 5 folds. The COD removal rate in swine wastewater using PSB, strains IP-4 and IP6-7 were obtained 91% and 85%, respectively.

  • PDF

Removal Characteristics of Hazard Organic Substances in the Multi-stage Ozone Contactor (다단오존접촉조에서 유해화학물질의 제거특성)

  • 박영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.41-49
    • /
    • 1999
  • The water treatment by was performed to remove VOC and organic substances in the multi-stage ozone contactor. Ozone is mainly utilized to change the chemical structures of organic substance, of which finally has the purpose to degrad them. The removal efficiency of VOC has 20~60% at the ozone concentration of 3 ppm, in case of trichloroethylene, its efficiency is reduced by 85% at the ozone contact time of 8 min. Design factors such as the number of stage, ozone concentration, zone contact time are determined for optimal treatment in the multi-stage contactor.

  • PDF

A Survey on the Sanitary Management with Step-by-step Working Process in Food Service Institutions (집단급식소의 작업 단계별 위생관리에 대한 실태 조사)

  • Shin, Dong-Hwa;Soh, Gowan-Soon;Kim, Hyeong-Eun;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.3
    • /
    • pp.165-172
    • /
    • 2007
  • Sanitary management with step-by-step working process and dietician's perception against them at 98 food service institutions located in Jeollabuk-Do were surveyed. Food service institutions included 13 hospitals, 38 schools,40 enterprises, and 7 others. Practice ratio of sanitary management items at purchasing and receiving step of food and food materials in food service institutions were 59.2-98.0%, and they were higher than those of other steps. In pre-treatment step, practice ratio of 'Undoing treatment of foods on the ground' in hospital was higher (53.8%) than those of enterprise (32.5%) and school (34.2%), and needed the improvement of pre-treatment procedure in enterprise and school. Practice ratio of all sanitary management items in cooking step were below 30%, and needed the improvement of cooking procedure. In storage step, the improvement of cooking procedure in school and enterprise were needed. Practice ratio of all sanitary management items in distribution step were low, and needed the improvement of this working procedure. However, in spite of low practice ratio on these items, dietician's perception against sanitary management items in all steps was low. Therefore, we estimated that the improvement of working processes and the conversion of dietician' perception on sanitary managements in food service institutions were needed.

Citizen's Attitude to Treatment Facilities of Municipal Solid Waste in Small City (폐기물 처리시설에 관한 소도시 시민의 의식 조사)

  • 장성호;박진식
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.70-79
    • /
    • 1999
  • A questionary survey was conducted to investigate citizen's attitude to treatment facilities of municipal solid waste in Miryang during 8. June of 1998 and 22 June of 1988. Collection effiencies was 86.7%, as 260 individuals of the 300 individuals. The survey showed that 43.0% of answers recognized seriousness of problem of the waste treatment and 33.1% of respondents concerned about recycle of organic waste. 40.8% of total answers said that they most hated landfill site among waste treatment facilities, and most citizens wanted as much distant as possible from waste treatment facilities. It was investigated that the greater part of respondents wanted the greatest compensation. About 58% of respondents was opposed to complete waste treatment facilities. 36.2$ among answers wanted establishment of waste treatment facilities in an industrial complex or an industrial area. The majority of respondents was willing to increase recycle rate and recognized seriousness of landfill site security. The majority of citizens do not trust environmental administration of Miryang City and they think that democracy and open of administration need for overcome MINBY.

  • PDF

A Study on the Treatment of Organic Wastewater by Ozone Electrolysis (유기성 폐수의 오존전해처리에 관한 연구)

  • 정홍기;이태호
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.59-63
    • /
    • 1996
  • To treat certain wastewater that has alcohol and phenol, we performed the ozone electrolysis by using the titanium electrode. In this experiment, we examined decomposition voltage of organics, time for electrolysis, and removal efficiency of organics. In addition we compared the ozone oxidation electrolysis. The followings are results; 1. When it comes to the alcohol treatment in wastewater, ozone electrolysis showed higher removal efficiency than ozone oxidation or electrolysis. 2. After comparing the decomposition rate of methylalcohol, ethylalcohol, and prophylalcohol in ozone electrolysis, we knew the fact that increasing carbon number made the decomposition rate slow. 3. According to the treatment of alcohol by ozone electrolysis, decomposition voltage was 50V, time for electrolysis was three hours, and treatment acidity was neutral (pH 6.5 - 8.1). 4. Ozone electrolysis was effective to the phenol treatment. When we treated phenol by using ozone electrolysis for three hours, TOC treatment efficiency was 95%. However, ozone oxidation just showed 45% treatment efficiency.

  • PDF

A Study on the Treatment of Dyeing Wastewater Using the Supernatant after Treatment of Acidic Metal Wastewater (중금속 산폐수 처리 후의 상등액을 이용한 염색폐수처리 연구)

  • 신진명;박장진;김미자;주소영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • Traditionally the supernatant after chemical treatment of metal acid wastewater is discharged in environment. The supernatant can be used as a coagulant as it contains effective metals. The aim of this study is to investigate the feasibility of treatment of dyeing wastewater using the supernatant after treatment by magnesium hydroxide and dolomite($Ca{\cdot}Mg(CO_3)_2$), of acidic metal wastewater. In dyeing wastewater treatment with the supernatant, optimum pH and dosage were determined. COD, turbidity and color were analyzed to evaluate the performance of treatment. In the case of magnesium hydroxide, the optimum dosage was 10%(v/v) for supernatant A and 3%(v/v) for supernatant B. Color, turbidity and COD removal was 99~100%, 85~97% and 43~53%, respectively. In the case of dolomite, the optimum dosage was 10%(v/v) for supernatant A and 3% for supernatant B. Color, turbidity and COD removal was 96~99%, 62~9l% and 52~53%, respectively.

A Survey of Water Quality and Improvement Measure of Imjin-River (임진강수계의 수질조사 및 개선방안)

  • 김형진;백영석;이준석
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.66-75
    • /
    • 1995
  • This survey is executed about the water quality and improvement measure of Imjin- river. The results are summarized as follows; 1 ) Ammonia nitrogen concentration in tap water was two times higher than drinking water standard. 2) The concentration of BOD in textile wastewater was 235ppm which is higher than wastewater distribution standard and leather wastewater showed high nitrogen concentration. 3) Water quality of the Imjin- river upstream was not in problem but that of Shin- stream showed somewhat high concentration in BOD, COD, and ammonia nitrogen. Especially the detected Cynide compound on the lower of Shin- stream implied seriously polluted condition. 4) The heavy metal in soil of the river bed was not detected but iron, zinc was detected to high concentration. 5) It Is urgently suggested to build more municipal sewage and sanitary treatment plants, and run dredging and river bed rearrangement project. 6) The Construction of the wastewater treatment complexes of relevant industries shall be propelled as soon as possible.

  • PDF