• Title/Summary/Keyword: sanitary quality

Search Result 330, Processing Time 0.024 seconds

Groundwater Quality Monitoring Network Design Using Integer Programming (정수계획법을 이용한 지하수 수질관측망의 설계)

  • Lee, Sang-Il;Kim, Hak-Min
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.5
    • /
    • pp.557-564
    • /
    • 1999
  • Monitoring of groundwater Quality is essential for the preservation of groundwater resources. In practice. however, groundwater monitoring network is designed based on the experience and intuition of experts or on the convenience. This study proposes a simulation-optimization approach for the optimal design of monitoring networks. In it, the predicted three-dimensional concentration data are used as the input of an optimization problem. Various design objectives and constraints are considered and the problem is formulatcu as the 0-1 integer programming. The methodology was applied to a sanitary landfill site. The results show that the monitoring network configuration changes as the monitoring goal, operation time and constraints vary. The proposed method turns out to be an efficient tool for the wide range of groundwater Quality monitoring network design problems.oblems.

  • PDF

Quality Characteristics of Dried Squid (Todarodes Pacificus) by Cold Air Drying Process (냉풍건조공정을 이용한 마른오징어의 품질특성)

  • Hong, Joo-Heon;Bae, Dong-Ho;Lee, Won-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.5
    • /
    • pp.635-641
    • /
    • 2006
  • In an attempt to find ways of improving the quality and sanitary state of dried squid, this study compared artificial drying methods i.e. hot air drying and cold air drying with natural drying method. The drying rates of squid were in the order of hot air, cold air and natural drying. However, cold-air drying was slower than natural drying at $7^{\circ}C$. The drying rates increased with increasing drying temperature. When drying temperature was close to the dew point on a dehumidifier surface, which was the case with cold air drying at $7^{\circ}C$, the driving force for dehumidification was lower than under other drying conditions, which resulted in a lower drying rate. There were little color differences between the drying methods and temperature. Squid dried by cold air-drying had better mechanical texture and sensory qualities than with other drying methods. In addition, the cold air drying method maintained superior quality in terms of the contents of amino acids, taurine, EPA, DHA, other fatty acids and a low TBA value than the other drying methods.

Study on the Hygenic Water Quality in Imha Dam (임하댐의 위생학적 수질조사 연구)

  • 이희무
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.25-34
    • /
    • 1995
  • A Study on environmental Investigation in Imha Dam for the finding the degree of water quality and heavy metals was carried out at 4 sampling station during the period from August 15, 1993 to May 7, 1994. The results were as follows. 1. The ranges of values of pH for water were st. 1-7.56, st.2-7.77, st.3-7.9, st.4-7,7 on the average. Total average of pH values were 7.56-7.9 2. The ranges of values of DO for water were st.1-8.71($mg/{\ell}$), st.2-8.64($mg/{\ell}$), st.3-10. 25($mg/{\ell}$), st.4-9.01($mg/{\ell}$) on the average. Total average of DO of values were 8.64-10.25($mg/{\ell}$). 3. The ranges of values of BOD for water were st.1-1.1($mg/{\ell}$), st.2-1.0($mg/{\ell}$), st.3-0 86($mg/{\ell}$), st.4-0.99($mg/{\ell}$) on the average. Total average of BOD of values were 0.86-1.1($mg/{\ell}$). 4. The ranges of values of COD for water were st.1-1.12($mg/{\ell}$), st.2-1.4($mg/{\ell}$), st.3-0 98($mg/{\ell}$), st.4-1.46($mg/{\ell}$) on the average. Total average of COD of values were 0.98-1.46($mg/{\ell}$). 5, The ranges of values of T- N for water were st.1-0.36($mg/{\ell}$), st.2-0.49($mg/{\ell}$), st.3-0 23($mg/{\ell}$), st.4-0.83($mg/{\ell}$) on the average. Total average of T-N of values were 0.23-0.83($mg/{\ell}$). 6. The ranges of values of T-P for water were st.1-0.053($mg/{\ell}$), st.2-0.06($mg/{\ell}$), st.3-0.02($mg/{\ell}$), st.4-0.07($mg/{\ell}$) on the average. Total average of T-P of values were 0.02-0.07($mg/{\ell}$). 7. In the E. soli group distribution were counted st.1-1130, st.2-1113, st.3-152.3, st.4-1253 by the MPN test. Total distribution of E. soil group were 152.3-1253. 8. The concentration of heavy metals of Cu, Mn, Pb, Zn were measured st.1-0.59, 0.18, 0 04, 74.6( ${\mu}g/{\ell}$), st.2-0.39,0.29,0.03, 54.3(${\mu}g/{\ell}$), st.3-0.1,0.3, ND, 8(${\mu}g/{\ell}$), st.4-0.96, 0 26,0.23,45.6(${\mu}g/{\ell}$) on the average. Cd, Hg, Cr were not detected in the sampling site.

  • PDF

The Seasonal Distribution of Phytoplankton by Environmental Factors in Dongbok Reservoir (환경요인에 따른 동복호에서의 식물성플랑크톤 계절적 분포)

  • Jeong, Jin;Cho, Young-Gwan
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.1
    • /
    • pp.27-37
    • /
    • 1996
  • The taxa of phytoplankton in the Dongbok reservoir consisted of 6 classes, 9 orders, 4 4 suborders, 21 families, 42 genus, 86 species, 4 varieties and 1 formula; totally 91 t taxa appeared. It contained 3 major groups that is Chlorophyceae 51 taxa(56.0 % the most high rate), Bacillariophyceae 23taxa(25.2%), Cyanophyceae 10taxa(10.9%). The most abundant with 47 taxa was in December, the least with 11 taxa was in March during research every month. The component ratio of biomass each main groups, Bacillariophyceae(51 %, the most h high rate), Cyanophyceae(38.9%), Chlorophyceae(9.8%). The most abundant class at the biomass component ratio were Cyanophyceae which contained 82.6-98.0 % of it in May and September, Chlorophyceae 79.0% in August, and Bacillariophyceae increased continuously, specially in winter and autumn. The seasonal dominant groups were Microcystis aemginosa belong to Cyanophyceae in spring and autumn, some species of Chlorophyceae in summer and Melosira granulata belong to Bacillariophyceae in winter and late autumn. Dominant index ranged from 0.33 to 0.95. The season of the lowest index was autumn and the highest was spring. Species diversity indices ranged from 1.09 to 3.99. The water environmental factors of the Dongbok reservoir were that the values of water temperature ranged between $2.4~28.9^{\circ}C$, pH 7.2~8.3, conductivity 77.0~105.5us/cm, and transparency 1.2~2.8m, also the concentration of dissolved oxygen(DO) ranged of 6.9-14.6mg/L, total nitrogen(T-N) 0.38-1.84mg/L, total phosphorus (T-P) 0.011~0.028mg/L, and chlorophyll-a $7.0~29.9mg/m^3$. In this research the proper temperature of water for algae growth, $15~20^{\circ}C$, was maintained in April. May, November and December 1 The number of species that induced water color were 14 species, that caused taste-and-odor problems were 3 species and that caused filter clogging were 5 species. A Among them, the bloom of Anahaena macrospora that caused odor problem occurred l in May and of Microcystis aeruRinosa and M. lνensenberRii that caused filter clogging in May and September.

  • PDF

The Assessment and Recognition on Indoor Air Quality at Schools in Korea (전국 일부 학교 건축물 내의 실내 공기 및 인식도 조사)

  • Sohn Jong-Ryeul;Yoon Seung-Uk;Kim Jong-Hyuk;Lee Yong-Sik;Choi Han-Young;Kim Young-Sung;Son Bu-Soon;Yang Won-Ho;Kim Min-Hoi
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.3 s.57
    • /
    • pp.1-9
    • /
    • 2005
  • Recently, indoor air quality (IAQ) in workplace, residential environments and schools has been concerned of people, scientists and related the public, and has recognized the healthy effectsrelated to IAQ, specially in schools in Korea. Therefore, objectives of this study in this study were to measure and compare the perception of TAQ of selected air pollutants in Seoul from April to September 2004. Measurement place measured 2 schools of Seoul and local 9 schools (by Kyonggi Province, Chungchong-bukdo Chungchong-namdo, Chollado-bukdo, Cholla-namdo, Kyongsang-bukdo, Kyongsang-namdo, Kwangju, schoolin Pusan each 1 place). Temperature, humidity, illumination, carbon monoxide, carbon dioxide, TBC (total bacteria count), noise, PM10, TVOC(total volatile organic compounds), HCHO (formaldehyde) were measured simultaneously. Also, we Performed a questionnaire survey of 250 students and 50 teachers about their awareness for the importance of IAQ in their schools. Among this article, we handled noise, carbon monoxide, carbon dioxide, TBC, TVOC, HCHO, PM 10 in our conclusion. Major results were as follows ; Carbon monoxide (CO) was lower than indoor air standard of Korea. Carbon dioxide $(CO_2)$ appeared that 4 schools among our sample target school exceeded in normal standard. 4 schools were almost similar with normal standard. TBC appeared that 7 schools among 11 schools were higher than standard. Noise measured school's mean value passed exceeded standard. And school which passed over standard appeared to 7 schools among 11 schools. HCHO was exceeded 4 schools by standard that excess and certainly interrelation between school's establishment year and facilities of construction was detected. PM10 was exposed all schools by fitness in standard. TVOC appeared that 9 schools among 11 measurement school was exceeded health effect standard of Japan.

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF

A Study of Actual Condition on Operation and Management of Environmental Infrastructure in the Geum River System (금강수계 내 환경기초시설 운영실태에 관한 연구)

  • Lee, Jae-Woon;Park, Dong-Gi;Kwon, Young-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 2009
  • The various environmental problems that we face on today are basically about environmental quality. Since early 1960s affluent material was produced because of remarkable economic growth by many cooperations. However, for the lack of environmental policy, environmental pollutions has been serious. The central government should transfer the producing and consuming structure to environmental affinity through the regulations for developing Korea as a model of environmental nation which takes an active part in global environmental programme and in which the environment and economy are well harmonized. Moreover, the central government should take the lead in prevention of environmental pollution through the direct policies such as strengthening the discharge limit or setting up environmental basic institutions by securing budget for conserving environment. This thesis emphasize on the public institution among many environmental basic institutions for environmental anti-pollution project. It will find the problems with running those institutions, and will suggest the preview of improvement. Also, it is necessary to investigate of variation trend for inflow and pollutant loading to environmental infrastructure as increased of the diffusion rate as established and maintenance of sewer system. The purpose of this study is to investigate for inflow and pollutant loading to environmental infrastructure, and also to provide the method of efficiently maintenance and management. The results obtained were summarized as follows; 1. Survey of actual condition on operation and management of environmental infrastructure was evaluated the propriety of treatment process and problem of plant management. 2. Analysis of pollutant loading contribution for river system of environmental infrastructure with data analysis of water quality measuring network. 3. To investigate on case study for efficiently maintenance and management of environmental infrastructure. The result on this study was provide the method of efficiently maintenance and management with survey for establish and repair of sewer system and survey of actual condition on operation and management of environmental infrastructure in the water area of discharge to Geum River System. Application as guideline for establish and management of environmental infrastructure, and management of Geum River System. Also, application for preliminary data for fulfill-assess of total effluent regulation of water pollution.

A Study on the Importance, Satisfaction of Skin Care Shops Selection Attributes for Life Care Promotion - Focusing on the Sanitation - (라이프케어 증진을 위한 피부미용샵 선택속성의 중요도와 만족도 연구 - 위생요인을 중심으로 -)

  • Park, Chae-Young
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.7
    • /
    • pp.145-158
    • /
    • 2021
  • This study is aimed at identifying the important factors required by customers through importance-satisfaction analysis of how they choose skin care shops on the basis of certain factors and attributes at this time when there is an urgent need to improve the level of quality that meets their expectations and demands in combination with the quantitative expansion of skin care shops. To achieve this, a survey was carried out to 217 people over the age of 20 in Gwangju and Jeonnam area with experience in using skin care shop services. The SPSS v. 21.0 program was used to analyze the collected data. The results are summarized as follows. IPA grid analysis of the difference in importance-satisfaction of sub-factors for skin care shop choice showed that the items corresponding to the upper-left side of maintenance and strengthening, the upper-right side of stainability, and the lower-left side of gradual improvement were the 'sanitary control of tools and products', 'basic situation(legal compliance)', and 'workers' sanitary control', 'internal control of skin care shops', 'professionalism and skills of workers'and 'quality of services', respectively. Consequently, the results of this study will be based on the efficient operation of skin care shops, and further more the utilization of them is expected to expand the quantitative and qualitative base of the skin care industry.

Microbiological Quality Evaluation of Foods(Ojingeochaesomoochim : Vegetable Salad with Blanched Squid) That Went through Cooking Process after Heating Treatment in School Food Services (학교급식의 가열조리후처리 음식(오징어채소무침)에 대한 미생물학적 품질 평가)

  • Kim, Yang-Sook;Moon, Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.30 no.1
    • /
    • pp.51-63
    • /
    • 2014
  • A microbiological quality evaluation on cooked food, food materials and cooking equipment was conducted in 14 school food services in Changwon area, South Korea for Ojingeochaesomoochim (vegetable salad with blanched squid) which went through cooking process after heating treatment. Only 5 schools out of the 14 (35.7%) observed the sanitization criteria of the Korean School Meals Sanitization Management for raw vegetables (concentration of chlorine solution: 100ppm, immersion time of sanitizing: 5 min). The acceptance rates regarding the microbial standards for Korean school meals showed improvement before and after of sanitization: for onions 57.1% vs 71.4%; cucumber 42.9% vs. 78.6%. However, garlic showed adverse sanitizing effect as the acceptance rate went down from 42.9% to 35.7%. Blanched squid and red pepper paste was acceptable in all 14 schools (100%), while squid seasoned with red pepper powder was acceptable in only 42.9% of the schools. Microbial results for knives, cutting boards, mixing bowls were satisfactory, however 35.7% of sanitary gloves that were put on right before the seasoning showed poor sanitization, and this indicated high probability of cross-contamination from the gloves. We calculated that 57.1% of the cooked foods were in accordance with the microbial standards for Korean school meals. Therefore, it is strongly recommended to have verification process, especially on the effectiveness of sanitization of raw vegetables, in cooking foods through cooking process after heating treatment in HACCP system of school food service.

Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area (대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성)

  • 백성옥;송희봉
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF