• 제목/요약/키워드: sand density

검색결과 669건 처리시간 0.022초

韓國海岸植物의 生態學的 硏究 - 西海岸의 沙丘植生에 關하여 - (Ecological Studies on the Coastal Plants in Korea -On the Sand Duen Vegetation of the Western Coast-)

  • Lee,Woo Tchul;Sang-Keun Chon
    • The Korean Journal of Ecology
    • /
    • 제7권2호
    • /
    • pp.74-84
    • /
    • 1983
  • The dominant species of the sand vegetation in the western coast of Korea were Carex pumila, Ischaemum antheporoides, Calystegia soldanella, Carex kobomugi and Imperata cylindrica var. koenigii. The salt content of the sand dune soil and of the atmosphere of surveyed areas ranged from 3.93 to 13.86 mg% and from 25.81 to 168.86mg% respectively. Between the salt content of the atmosphere and that of the soil positive relationship was found. Species density and Simpson's index increased with the distance from the coast, the former was exponential, however, the latter was linear. The composition of biological types in the investigated stands were H-D4-R1-3-e or H-D4-R1-3-t. Relative numbers of psammophytes and rhizome psammophytes decreased with the distance from the coast, but those of other plants increased. The standing crop of the sand dune vegetation ranged from 0.04 to 491.64g/m2 and the average 27.77g/m2. This was varied as the stands and showed a linear increment as the distance from the coast was increased. The salt content of atmosphere significantly affected the density, T/R ratio in the standing crop and Simpson's index. The salt content of soil showed similar tendency on the density and the T/R ratio.

  • PDF

직접전단시험에 의한 모래의 전단강도에서 시편의 크기효과 (Scale Effects of the Specimen on Shear Strength of sand by Direct Shear Test)

  • 김준석;김지현
    • 한국재난정보학회 논문집
    • /
    • 제15권4호
    • /
    • pp.590-596
    • /
    • 2019
  • 연구목적: 직접전단시험의 문제점 중에 하나인 시험시편의 크기효과에 대하여 모래시료를 대상으로 실험적 연구를 수행하였다. 연구방법: 우리나라를 대표하는 모래인 주문진 표준사를 연구 대상으로 사용하였다. 상대밀도 50%, 60%, 70%, 80%에 대한 전단강도를 분석하기 위하여 대형직접전단시험을 수행한 후 소형직접전단기의 시험결과와 비교분석을 수행하였다. 연구결과: 상대밀도가 촘촘한(dense) 영역에서는 소형전단시험기의 내부마찰각이 비교적 큰 경향이 있는 것으로 분석되었다. 상대밀도가 중간(medium)정도의 영역에서는 대형전단시험기의 결과가 비교적 큰 경향이 있는 것으로 분석되었다. 결론: 모래흙에서 직접전단시험의 시료에 대한 크기 효과는 비교적 크지 않은 것으로 분석되었다.

각종 주물사의 특성과 주강품 주조에 적합한 인공사 선택 (Selection of Artificial Sand Suitable for Manufacturing Steel Castings through Evaluation of Various Foundry Sand Properties)

  • 김광식;김재형;김명준;김지태;권기명;김성규
    • 한국주조공학회지
    • /
    • 제43권3호
    • /
    • pp.107-136
    • /
    • 2023
  • 주강품 사형주조에는 천연규사가 보편적으로 사용되었고, 규사의 열적특성 부족에 의한 소착결함 억제를 위해, 크로마이트사가 사용되기도 하였으나, 반복 사용에 의한 골재 열화, 시스템샌드 혼입 문제, 분리 제거의 어려움, 높은 밀도에 따른 조형 시 하중증가, 크롬 함유 폐기물이 되는 단점이 있다. 최근에는 주조업계의 중요한 과제로써 산업폐기물 저감 및 대기환경 개선이 부각되고 있다. 종래의 주물사 사용 시 발생되는 문제점 해결과 주조공장의 환경개선을 위해서, 천연사를 대체 적용할 수 있는 다양한 인공사가 개발되어 소개되고 있다. 인공사는 용융분사법으로 제조된 인공사와 조립소결법으로 제조된 인공사 및 분쇄법으로 제조된 인공사로 분류할 수 있으며, 원료광물의 종류, 제조공법에 따라 상이한 물리적 특성을 나타낸다. 본 연구에서는 각종 주물사의 물성, 주형강도, 물리적 내구성, 열적 내구성, 소착시험편 주조 등의 비교 평가시험을 하였다. 밀도에 따른 주물사 실사용량, 주물사 형상에 따른 주형강도, 주물사의 물리적 및 열적 내구성, 주물사의 내열특성을 종합적으로 고려하였을 때, 아크용사법으로 제조된 용융인공사 A1 또는 분말식화염용사법으로 제조된 용융인공사 B가 대형주강품 주조에 가장 적합한 구형의 인공사로 판단된다.

수분함량과 측정주파수에 따른 사질토 지반의 유전상수 변화 (Variation of Dielectric Constant of Sand due to Water Content and Measuring Frequency)

  • 이주형;오명학;박준범;김형석
    • 한국지반공학회논문집
    • /
    • 제18권6호
    • /
    • pp.129-139
    • /
    • 2002
  • 최근 지반 특성과 지반 오염도의 조사를 위해 유전상수 측정기법을 적용하기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 다양한 함수비와 건조단위중량을 갖는 화강풍화토와 주문진표준사의 유전상수를 75kHz~12MHz의 주파수 범위에서 측정하였다. 사질토의 유전상수는 주파수가 증가함에 따라 감소하는 분산거동을 보였다. 또한 함수 비나 건조단위중량이 증가함에 따라 배향분극에 기여하는 물분자의 양이 증가하고 유전상수가 1인 공기의 양이 감소하여 유전상수가 증가하였다. 흙의 유전특성은 함수비와 건조단위중량을 모두 고려한 수분밀도에 선형적으로 비례하는 경향을 나타내었다. Maxwell식, Topp식, CRIM식에 의한 계산값과 측정된 값을 비교한 결과 기존의 식은 유전상수의 분산거동을 고려하지 못하고 있기 때문에 저주파에서는 측정값과 차이를 나타내었다.

고결모래의 콘선단저항에 대한 영향요인 분석 (Analysis of Influencing Factors on the cone resistance in Cemented Sand)

  • 이문주;최성근;조용순;이우진;김태준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.628-635
    • /
    • 2008
  • A series of cone penetration tests in large calibration chamber were performed to investigate the effect of cementation level, relative density and vertical confining stress on cone resistance. From the experimental results, it was observed that the cone resistance is increased with increasing gypsum content, relative density, and confining stress. The increasing ratio on cone resistance of cemented sand compared with that of uncemented sand, that is IR($q_c$), was increased with increasing gypsum content and relative density, whereas it was decreased as the vertical confining stress increases. It was also observed that the cementation of granular soil influences the behavior of ground at low level of confining stress and its effect is diminished with depth.

  • PDF

국내 부순모래의 물리적 성질과 입자 특성에 관한 연구 (A Study on Physical and Particle Properties of Crushed Sand in Korea)

  • 윤기원;김기훈;고경택;이장화;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.352-355
    • /
    • 2004
  • Crushed sand is made by crushing the rocks artificially. With a wide shortage of natural river sand all over the region in Korea, demand for crushed sand are becoming increased. However, Informations as to crushed sand are insufficient. In this paper, the actual conditions of crushed sand related to producing and quality variation are investigated. 29 manufacturing company of crushed sand are reviewed. According to results, density of most crushed sand tested exceeded 2.5g/cm3, and absorption ratio meet the requirement of KS except one sample. For grain properties, passing amount of 0.08mm sieve satisfied the requirement of KS except one sample. Grain distribution of most crushed sand is estimated $54.26\%$. But 6 crushed sand sample did not meet the requirement of KS. Fineness modulus and grading are varied from manufacturing region. 18 samples of crushed sand among 29 samples deviated the minimum level of standard grading range by KS. Therefore, improvement of grain properties of crushed sand is urgently needed to manufacture better crushed sand.

  • PDF

유동층 생물막 반응기를 이용한 고농도 질산성 폐수의 탈질화에 관한 연구 (The High Rate Denitrification of Nitric Acid Wastewater in a Fluidized Bed Biofilm Reactor)

  • 신승훈;김민수;박동일;안재동;장인용
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.95-104
    • /
    • 1997
  • The objectives of this study are to investigate the effect of media on the removal efficiency of nitrate-nitrogen and the biofilm thickness in the fluidized bed biofilm reactor(FBBR) used for the high rate denitrification of nitric acid wastewater. Granular activated carbon(GAC) of 1.274 mm diameter and sand of 0.455 mm diameter were used as the media in the FBBR of 0.05 m diameter and 1.5 m height. As the nitrate-nitrogen concentration of the influent was increased stepwise from 600 to 4800 mg/l, the nitrate- and nitrite-nitrogen concentration of the effluent, biofilm thickness and biofilm dry density were measured to study the effects of media on the denitrification efficiency. The biofilm thickness increased with the substrate loading rate, and the biofilm dry density decreased with the increase of the biofilm thickness. At the influent nitrate-nitrogen concentration of 2400 mg/l, the removal efficiency in the FBBR with GAC was 88%, while that in the FBBR with sand was 99.6%. The biofilm in the FBBR with GAC was so thick, 754.9 $\mu$m, as to increase the mass transfer resistance, compared to that, 143.7 $\mu$m, in the FBBR with sand. The maximum specific denitrification rate in the FBBR with GAC was 15.0 kg-N/m$^3\cdot$ day, while that in the FBBR with sand was 18.0 kg-N/m$^3\cdot$ day. The biomass concentration in the FBBR with sand exhibited the high value 37 kg/m$^3$.

  • PDF

모래의 미소변형 전단탄성계수에 대한 고결영향 분석 (Analysis of cementation effects on Small-strain Shear Modulus of Sand)

  • 이문주;추현욱;이종섭;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.1431-1437
    • /
    • 2008
  • The small-strain shear modulus ($G_{max}$) of uncemented sand is affected by the the mean principal stress and void ratio, and it has been known that the cementation and aging also affect to $G_{max}$ of sand. For extensive understanding about the effect of cementation on the $G_{max}$ of sand, a series of bender element tests was conducted on the cemented specimens prepared in a large calibration chamber by pluviation of the sand-gypsum mixture. It was observed from the experimental results that the $G_{max}$ of cemented sand is higher above 10 times than value of uncemented one, and it increases exponentially with the gypsum content increases. Whereas, the increase of the vertical stress from 50kPa to 200kPa and the relative density from 40% to 80% result in 20~30% and 2 times increase of $G_{max}$, respectively. It means that the gypsum content, that is cementation level, is the most influential factor on the $G_{max}$ of cemented sand. In addition, the effect of relative density on $G_{max}$ was more apparent on cemented sand than uncemented one.

  • PDF

Effects of loading frequency and specimen size on the liquefaction resistance of clean sand

  • Sung-Sik Park;Dong-Eun Lee;Dong-Kiem-Lam Tran
    • Geomechanics and Engineering
    • /
    • 제37권2호
    • /
    • pp.123-133
    • /
    • 2024
  • This study investigates the effects of loading frequency (f) and specimen size on the liquefaction resistance of clean sand. A series of cyclic direct simple shear tests were conducted on Jumunjin sand with varying consolidated relative densities (40% and 80%), f values (0.05, 0.10, and 0.20 Hz), and diameter to height (D/H) ratios (3.63, 3.18, 2.82, and 2.54). The results demonstrated the significant influence of f and D/H ratio on the number of cycles to liquefaction (Ncyc-liq) and the cyclic resistance ratio (CRR15). It was observed that increasing f linearly increased Ncyc-liq. Increasing the specimen height also led to higher Ncyc-liq values irrespective of the f or relative density. Moreover, a positive correlation between CRR15 and f indicated that higher f yielded higher CRR15. This relationship was more pronounced in dense sand than in loose sand. Specimen height also significantly affected CRR15, with increasing the specimen height resulting in higher CRR15 values. Furthermore, the effect of f on CRR15 was less significant compared to the influence of specimen height. The effect of f on the normalized cyclic resistance ratio (NCRR) was relatively negligible for loose sand but more substantial for dense sand depending on the D/H ratio. Data analysis revealed that the NCRR generally decreases as the D/H ratio increases. An interpolation formula was provided to calculate the NCRR based on the D/H ratio regardless of the f and relative density.

포화(飽和)모래의 전단강도특성(剪斷强度特性)에 관(關)한 실험적(實驗的) 연구(研究) -대구지역(大邱地域) 낙동강(洛東江) 모래에 대해- (Experimental Study on the Shear Strength Characteristics of the Saturated Sand)

  • 김영수;서인식;김병탁
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1417-1431
    • /
    • 1994
  • 본 연구에서 삼축압축시험기를 이용하여 낙동강유역 모래에 대한 상대밀도, 전단변형어속도, 구속압력의 변화에 의한 전단강도 특성을 고찰하였다. 그리고 Lade 모델과 수정 Lade 모델의 결과는 실험에 의하여 비교하였다. 전단변형제어속도, 상대밀도 그리고 구속압력변화에 의한 결과를 요약하면 다음과 같다. 1) 낙동강유역의 모래에 대해 Coulomb의 식을 이용할 수 있는 응력의 한계는 변형제어속도가 0.08%/min일 때 120~200 kpa이고 0.5%/min일 때 120~150 kpa의 범위로 고찰되었다. 이들 한계범위들은 석회질 모래나 양입도의 석영질 모래에 비해 적게 나타났다. 2) 변형제어속도와 상대밀도 모두가 Lade 모델과 수정 Lade 모델에 필요한 매개변수에 많은 영향을 미친다. 따라서 현장에서는 하중조건과 지반조건을 정확히 파악하여 적절한 매개변수를 사용하는 것이 중요하다. 3) 변형제어속도와 상대밀도의 변화에 따른 구성모델식에 의한 파괴시 주응력비는 전반적으로 변형제어속도에는 큰 영향을 받지 않으나, 상대밀도와 구속압력이 구성 모델식의 결과에 영향을 미치는 것으로 나타났다. 따라서 낙동강유역의 모래에 대한 응력-변형거동의 정확한 예측을 위해서는 다양한 조건에 대한 연구가 필요할 것으로 판단된다. 4) Lade 모델과 수정 Lade 모델에서 결정된 파괴시 주응력비와 파괴포락선의 내부마찰각을 실측치와 비교한 결과, 본 연구에서 사용된 구속응력 범위내에서는 Lade 모델이 수정 Lade 모델보다 평균적으로 실측치에 더 근접함을 보여 주었다.

  • PDF