• Title/Summary/Keyword: sampling rate of frequency

Search Result 277, Processing Time 0.026 seconds

The study on high speed A/D conversion implementation employing I/Q compensating algorithm for 3-D radar signal processor (I/Q 보정기능을 갖는 3차원 레이더 신호처리기용 고속 A/D 변환 기법 연구)

  • 조명제;김수중
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.67-76
    • /
    • 1997
  • In radar signal processing, an A/D converter with sufficient dynamic range and high sampling speed is required to detect the weakest target signals in heavy clutter and ECM environments. As the sampling frequency increases, the amount of digital data transfered to the signal processing module is also increased. To overcome these massive data transfer burden, we need an A/D conversion module with an enough data transfer rate. In this paper, we proposed an implementation scheme of a new A/D conversio module that can be used in multi-mode 3-D phased array radar signal processing system, and evaluated the performance. The proposed A/D conversion module is implemented with a standard A/D converter and a 6U-standard VME bus.

  • PDF

Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis (단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정)

  • U, One Sang;Kang, Seong Min;Choi, Seong Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.

A Technique for Fast Sampling Measurement of Digital Frequency Relay (디지털주파수계전기의 고속 샘플링추정기법)

  • Nam, S.B.;Lee, H.G.;Ma, S.B.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.185-190
    • /
    • 2006
  • Frequency and phasor are the most important quantities in power system operation because they can reflect the whole power system situation. Frequency reflects the dynamic energy balance between load and generating power, while operators use phasor to constitute the state of system and, moreover, phasor based line relays are currently used in most power systems. So frequency and phasor are regarded as indices for the operating power systems in practice. The proposed technique is suitable for estimation near-nominal, nomina), and off-nominal frequencies. It is useful in designing microprocessor-based relays and meters that need to measure power system frequency. Performance test results, using signals from EMTP source and Excel program, indicate that the proposed technique can provide accurate estimates within 16ms. Maximum estimation errors observed during testing are of the order of 0.006Hz for nominal, near-nominal, and off-nominal frequencies. The proposed technique provides accurate estimates in presence of noise and harmonics and in case ground fault. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Frequency Domain based Positioning Method using Auto Regressive Modeling in LR-WPAN (주파수 영역상의 AR 모델링 기반 이용한 LR-WPAN용 무선측위기법)

  • Hong, Yun-Gi;Bae, Seung-Chun;Choi, Sung-Soo;Lee, Won-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6C
    • /
    • pp.561-570
    • /
    • 2009
  • Ultra-wideband communication systems based on impulse radio have merits that are possible for the high data rate transmission, high resolution ranging are positioning system. Conventionally, in order to accomplish these features, the high-speed ADC (Analog to Digital Convertor) is necessary to apply radio determination system operating in time domain. However, considering low rate - wireless personal area network (LR-WPAN) aims to low-cost hardware implementation, the expensive ADC converting GHz sampling per second is not appropriate. So, this paper introduces a low complex AR (Auto Regressive) model based non-coherent ranging scheme operating in frequency domain with using low-speed ADC utilizing analog Voltage Control Oscillator (VCO) mode for the frequency domain transformation. To verify the superiority of the proposed ranging and location algorithm working in frequency domain, the suggested IEEE 802.15.4a TG channel model is used to exploit affirmative features of the proposed algorithm with conducting the simulation results.

Current Status of an International Co-Operative Research Program, PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE) (국제공동연구 PARTRIDGE를 통한 확률론적 건전성 평가 기술 개발 현황)

  • Kim, Sun Hye;Park, Jung Soon;Kim, Jin Su;Lee, Jin Ho;Yun, Eun Sub;Yang, Jun Seog;Lee, Jae Gon;Park, Hong Sun;Oh, Young Jin;Kang, Sun Yeh;Yoon, Ki Seok;Park, Jai Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.62-69
    • /
    • 2013
  • A probabilistic assessment code, PRO-LOCA ver. 3.7 which was developed in an international co-operative research program, PARTRIDGE was evaluated by conducting sensitivity analysis. The effect of some variables such as simulation methods (adaptive sampling, iteration numbers, weld residual stress model), crack features(Poisson's arrival rate, maximum numbers of cracks, initial flaw size, fabrication flaws), operating and loading conditions(temperature, primary bending stress, earthquake strength and frequency), and inspection model(inspection intervals, detectable leak rate) on the failure probabilities of a surge line nozzle was investigated. The results of sensitivity analysis shows the remaining problems of the PRO-LOCA code such as the instability of adaptive sampling and unexpected trend of failure probabilities at an early stage.

Study on Rainfall Characteristics for the Millimeter-wave Communication Systems-Comparisons of Rainfall rate data from Several observation methods.

  • Chung, H.S.;Song, B.H.;Lee, J.H.;Park, K.M.;Lee, K.A.
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.132-134
    • /
    • 1999
  • Rainfall characteristics for designing the optimum millimeter-wave communication systems from two rainfall data set was analyzed. Two rainfall data sets were compared; one-minute rainfall rate data, one-hour synoptic observation data. Each data set has different observation method, sampling frequency. We looked for tendency and quality confluence between two data sets. We showed several results using one-minute rainfall data by millimeter-wave attenuation model. A climatological one-minute rainfall rate data set over Korean Peninsula will be made after data quality control procedure

  • PDF

Performance Analysis for TR-UWB System Exploiting Complex Frequency-Components (복소 주파수 성분 처리를 통한 TR-UWB 시스템의 성능분석)

  • Jang, Dong-Heon;Yang, Hoon-Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.2
    • /
    • pp.253-260
    • /
    • 2009
  • This paper, mathematically analyzes the performance of newly proposed TR-UWB system which the frequency components of a UWB pulse were processed so that the system could be implemented with ADCs of a few MHz sampling rate, and presents the comparison with an existing frequency-domain based TR-UWB system. The comparison is mainly based on the SNR ratio which depends on the mean and the variance of the frequency components. We also shows that the simulation results to support the theoretical analysis where the comparison is made under the IEEE 802.15.3a channel model as well as AWGN channel.

Adaptive Subtraction Method for Removing Variable Powerline Interference of ECG (ECG 신호의 가변적인 전력선 잡음 제거를 위한 적응형 차감기법)

  • Jeon, Hong-Kyu;Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.447-454
    • /
    • 2011
  • Power-line interference(PLI) can distort certain regions in analysing the ECG signal. In particular, the regions such as P and R wave that are important element in diagnosing with arrhythmia is expressed as different type of noise according to the case whether power-line frequency is multiples of sampling frequency and or not. Noise characteristics is also divided into linearity and non-linearity. In this paper, adaptive subtraction method for removing variable PLI of ECG signal is proposed. We classify the multiple relationship between power line and sampling frequency as Multiple and Non-multiple. PLI of Linear segment is extracted through moving average filter, PLI of non-linear segment is extracted through the interference component that is extracted in the linear segment and stored in the temporary buffer. The performance of P wave and R wave detection is evaluated by using 119 data record of MIT-BIH arrhythmia database. The achieved scores indicate P wave detection rate of 97.91%, R wave detection rate of 96.66% and P wave detection rate of 99.01%, R wave detection rate of 97.93% accuracy respectively for Notch filter and proposed subtraction method.

A Study on Factors Affecting Constipation of Female High School Students (일부 여고생의 배변실태와 생활습관과의 관련성)

  • Kim, Eun-Joo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.11 no.2
    • /
    • pp.71-87
    • /
    • 2010
  • Objectives: The purpose of this study was to find out the prevalence of constipation, related factors of constipation of female high school students. Methods: The study subjects were 322 students of Y high schools located in a Suwon city, who were selected by the accidental sampling from November 2009. We analyzed the data by frequency analysis, Chi-square test, Logistic regression analysis using SPSS ver.12.0. Results: The results of this study were summarized as follows: A prevalence rate of self-reported constipation was 55.3%. From the Logistic analysis by self-reported method, leading causes of constipation on the students were drinking beverage, the less frequency of having meals, irregular time of having meals, not eating breakfast, insufficient exercise and not evacuating the bowels regularly. Conclusions: Based on these results, intervention to increase the amount of beverage constipation, intake of vegetable, regularity of taking meals, stress management should be provided to prevent the constipation.

  • PDF

On Implementing the Digital DTMF Receiver Using PARCOR Analysis Method (PARCOR 분석 방법에 의한 디지털 DTMF 수신기 구현에 관한 연구)

  • Ha, Pan Bong;ANN, Souguil
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.196-200
    • /
    • 1987
  • The following methods are proposed for implementing digital dual tone multi-frequency (DTMF) receiver: using infinite impulse response(IIR) digital filters, period-counting algorithm, discrete Fourier transform(DFT), and fast Fourier transform(FFT)[2]. The PARCOR(Partical Correlation) analysis method which has been widly used in the speech signal processing area is applied to the dual tone multi-frequency(DTMF) signal detection. This method is easy to implement digitally and stronger to digit simulation of speech than any other methods proposed up to date. Since sampling rate of 4KHz is used in the DTMF receiver for the detection of input DTMF signal originally sampled at 8KHz, it effects two times higher multiplexing efficiency.

  • PDF