Abstract
Power-line interference(PLI) can distort certain regions in analysing the ECG signal. In particular, the regions such as P and R wave that are important element in diagnosing with arrhythmia is expressed as different type of noise according to the case whether power-line frequency is multiples of sampling frequency and or not. Noise characteristics is also divided into linearity and non-linearity. In this paper, adaptive subtraction method for removing variable PLI of ECG signal is proposed. We classify the multiple relationship between power line and sampling frequency as Multiple and Non-multiple. PLI of Linear segment is extracted through moving average filter, PLI of non-linear segment is extracted through the interference component that is extracted in the linear segment and stored in the temporary buffer. The performance of P wave and R wave detection is evaluated by using 119 data record of MIT-BIH arrhythmia database. The achieved scores indicate P wave detection rate of 97.91%, R wave detection rate of 96.66% and P wave detection rate of 99.01%, R wave detection rate of 97.93% accuracy respectively for Notch filter and proposed subtraction method.
Keywords
Power-line interference(PLI); Subtraction method; Multiple relationship; Linearity and Non-linearity; ECG;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Dotsinsky I.A., I.K.Daskalov. Power-line Interference Cancellation in ECG Signals, Biomed. Instr. Technol., 39, 155-162, 2005.
2 Mark, R., Moody, G.: MIT-BIH Arrhythmia Database Directory. MIT(1988) http://physionet.org/physiobank/
3 Levkov C., G. Mihov, R. Ivanov, I. Daskalov, I.Christov, I.Dotsinsky. Removal of Power-line Interference from the ECG: A Review of the Subtraction Procedure, BioMed.Eng.OnLine, 4,50.n," J. Electrocardiol., vol. 32, pp. 30-37, 2005.
4 전홍규, 조익성, 권혁숭, "가변주파수를 고려한 차감기법의 전력선 잡음 제거 알고리즘," 통신학회동계종합학술발표회 논문 초록집, vol. 41, pp. 78, 2010년.
5 Huhta JC, Webster JG: 60 Hz interference in electrocardiography. IEEE Trans Biomed Eng, 20:91-100, 1973.
6 Ma WK, Zhang YT, Yang FS: A fast recursive-least-squares adaptive notch filter and it is applications to biomedical signals. Med Biol Eng Comput, 37:99-103, 1999.   DOI   ScienceOn
7 전홍규, 조익성, 권혁숭, "리듬분석과 비트매칭을 통한 조기심실수축(PVC) 검출,"한국해양정보통신학회 논문지, 제 13권 11호, pp. 2391-2398. 2009년 11월.
8 Thong, T., J. McNames, M. Aboy, B. Goldstein, "Prediction of paroxysmal atrial fibrillation by analysis of atrial premature complexes", IEEE Trans. On Biomed. Eng., 51(4), pp. 561-569, 2004.   DOI   ScienceOn
9 Ziarani AK, Konrad A: A Nonlinear Adaptive Method of Elimination of Power Line Interference in ECG Signals. IEEE Trans Biomed Eng, 49:540-547, 2002.   DOI   ScienceOn
10 Dotsinsky IA, Todor Stoyanov. Power-line interference Removal from ECG in Case of Power-line Frequency Variations. Bioautomation, 88-96, 2008.
11 Christov, I., Dynamic powerline interference subtraction from biosignals. Medical Enginnering &Technology, 24, 169-172, 2000.