• Title/Summary/Keyword: sample selectivity

Search Result 99, Processing Time 0.028 seconds

The Electrical Improvement of PZT Thin Films Etched into CF4/(Cl2+Ar) Plasma

  • Koo Seong-Mo;Kim Kyoung-Tae;Kim Chang-Il
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.6
    • /
    • pp.223-226
    • /
    • 2004
  • The PZT thin films are one of well-known materials that has been widely studied for ferroelectric random access memory (FRAM). We etched the PZT thin films by $CF_{4}/(Cl_{2}+Ar)$ plasma and investigated improvement in etching damage by $O_{2}$ annealing. The maximum etch rate of the PZT thin films was 157 nrn/min and that the selectivity of the PZT thin films to Pt was 3.1 when $CF_{4}(30{\%})$ was added to a $Cl_{2}(80{\%})/Ar(20{\%})$ gas mixing ratio. To improve the ferroelectric properties of PZT thin films after etching, the samples were annealed for 10 min at various temperatures in $O_{2}$ atmosphere. After $O_{2}$ annealing, the remanent polarization of the asdeposited films was $34.6{\mu}/cm^{2}$ and the sample annealed at 650, 550, and $450^{\circ}C$ was 32.8, 22.3, and $18.6{\mu}/cm^{2}$, respectively. PZT thin films with $O_{2}$ annealing at $450^{\circ}C$ retained $77{\%}$ of their original polarization at 106 cycles. Also as the annealing temperature increased, the fatigue properties improved. And the leakage current was decreased gradually and almost recovered to the as-deposited value after the annealing at $450^{\circ}C$.

Neck dissection for oral squamous cell carcinoma: our experience and a review of the literature

  • Rani, Pooja;Bhardwaj, Yogesh;Dass, Praveen Kumar;Gupta, Manoj;Malhotra, Divye;Ghezta, Narottam Kumar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.299-305
    • /
    • 2015
  • Objectives: This article describes our experience with neck dissection in 10 patients with oral squamous cell carcinoma. Materials and Methods: Between January 2007 and October 2009, 10 patients underwent primary surgery for the treatment of squamous cell carcinoma of the oral cavity. For patients with $N_0$ disease on clinical exam, selective neck dissection (SND [I-III]) was performed. In patients with palpable cervical metastases (N+), modified radical neck dissections were performed, except in one patient in whom SND (I-III) was performed. The histopathologic reports were reviewed to assess the surgical margins, the presence of extra-capsular spread, perineural invasion, and lymphatic invasion. Results: On histopathologic examination, positive soft tissue margins were found in three patients, and regional lymph node metastases were present in five of the ten patients. Perineural invasion was noted in five patients, and extra nodal spread was found in four patients. Regional recurrence was seen in two patients and loco-regional recurrence plus distant metastasis to the tibia was observed in one patient. During the study period, three patients died. Seven patients remain free of disease to date. Conclusion: Histopathological evaluation provides important and reliable information for disease staging, treatment planning, and prognosis. The philosophy of neck dissection is evolving rapidly with regard to the selectivity with which at-risk lymph node groups are removed. The sample size in the present study is small, thus, caution should be employed when interpreting these results.

Effect of Hydrophobic Coating on Silica for Adsorption and Desorption of Chemical Warfare Agent Simulants Under Humid Condition

  • Park, Eun Ji;Cho, Youn Kyoung;Kim, Dae Han;Jeong, Myung-Geun;Kim, Young Dok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.148.2-148.2
    • /
    • 2013
  • We prepared hydrophobic PDMS-coated porous silica as pre-concentration adsorbent for chemical warfare agents (CWAs). Since CWAs can be harmful to human even with a small amount, detecting low-concentration CWAs has been attracting attention in defense development. Porous silica is one of the promising candidates for CWAs pre-concentration adsorbent since it is thermally stable and its surface area is sufficiently high. A drawback of silica is that adsorption of CWAs can be significantly reduced due to competitive adsorption with water molecule in air since silica is quite hydrophilic. In order to solve this problem, hydrophobic polydimethylsiloxane (PDMS) thin film was deposited on silica. Adsorption and desorption of chemical warfare agent (CWA) simulants (Dimethylmethylphosphonate, DMMP and Dipropylene Glycol Methyl Ether, DPGEM) on bare and PDMS-coated silica were studied using temperature programed desorption (TPD) with and without co-exposing of water vapor. Without exposure of water vapor, desorbed amount of DMMP from PDMS-coated silica was twice larger than that from bare silica. When the samples were exposed to DMMP and water vapor at the same time, no DMMP was desorbed from bare silica due to competitive adsorption with water. On the other hand, desorbed DMMP was detected from PDMS-coated silica with reduced amount compared to that from the sample without water vapor exposure. Adsorption and desorption of DPGME with and without water vapor exposing was also investigated. In case of bare silica, all the adsorbed DPGME was decomposed during the heating process whereas molecular DPGME was observed on PDMS-coated silica. In summary, we showed that hydrophobic PDMS-coating can enhance the adsorption selectivity toward DMMP under humid condition and PDMS-coating also can have positive effect on molecular desorption of DPGME. Therefore we propose PDMS-coated silica could be an adequate adsorbent for CWAs pre-concentration under practical condition.

  • PDF

Ultra-fast Generic LC-MS/MS Method for High-Throughput Quantification in Drug Discovery

  • Kim, So-Hee;Yoo, Hye Hyun;Cha, Eun-Ju;Jeong, Eun Sook;Kim, Ho Jun;Kim, Dong Hyun;Lee, Jaeick
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.47-50
    • /
    • 2013
  • An ultra-fast generic LC-MS/MS method was developed for high-throughput quantification of discovery pharmacokinetic (PK) samples and its reliability was verified. The method involves a simple protein precipitation for sample preparation and the analysis by ultra-fast generic LC-MS/MS with the ballistic gradient program and selected reaction monitoring (SRM) mode. Approximately 290 new chemical entities (NCEs) (over 10,000 samples) from 5 therapeutic programs were analyzed. The calibration curves showed good linearity in the concentration range of 1, 2 or 5 to 2000 ng/mL. No significant ion suppression was observed in the elution region of all the NCEs. When approximately 300 plasma samples were continuously analyzed, the peak area of internal standard was constant and reproducible. In the repeated analysis of samples, the plasma concentrations and the area under the curve (AUC) were consistent with the results from the first analysis. These results showed that the present ultra-fast generic LC-MS/MS method is reliable in terms of selectivity, sensitivity, and reproducibility and could be useful for high-throughput quantification and other bioanalysis in drug discovery.

Direct Quantitation of Amino Acids in Human Serum Using a Stepwise-Dilution Strategy and a Mixed-Mode Liquid Chromatography-Tandem Mass Spectrometry Method

  • Lee, Jaeick;Lee, Seunghwa;Kim, Byungjoo;Lee, Joonhee;Kwon, Oh-Seung;Cha, Eunju
    • Mass Spectrometry Letters
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2018
  • A quantitation method for free amino acids in human serum was developed using a stepwise-dilution method and a bimodal cation exchange (CEX)/hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry system equipped with an electrospray ionization source (ESI/MS/MS). This method, which was validated using quality control samples, was optimized for enhanced selectivity and sensitivity. Dithiothreitol (DTT) was used as a reducing agent to prevent the oxidation of a serum sample ($50{\mu}L$), which was then subjected to stepwise dilution using 3, 30, and 90 volumes of acetonitrile containing 0.1% formic acid. Chromatographic separation was performed on an Imtakt Intrada Amino Acid column ($50mm{\times}3mm$, $3{\mu}m$) in mixed mode packed with CEX and HILIC ligands embedded in the stationary phase. Underivatized free amino acids were eluted and separated within 10 min. As a result of the validation, the precision and accuracy for the inter- and intraday assays were determined as 2.11-11.51% and 92.82-109.40%, respectively. The lowest limit of quantification (LLOQ) was $0.5-4.0{\mu}g/mL$ and the matrix effect was 80.22-115.93%. The proposed method was successfully applied to the quantitative analysis of free amino acids in human serum.

Ni Nanoparticle Anchored on MWCNT as a Novel Electrochemical Sensor for Detection of Phenol

  • Wang, Yajing;Wang, Jiankang;Yao, Zhongping;Liu, Chenyu;Xie, Taiping;Deng, Qihuang;Jiang, Zhaohua
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850134.1-1850134.10
    • /
    • 2018
  • Increasing active sites and enhancing electric conductivity are critical factors to improve sensing performance toward phenol. Herein, Ni nanoparticle was successfully anchored on acidified multiwalled carbon nanotube (a-MWCNT) surface by electroless plating technique to avoid Ni nanoparticle agglomeration and guarantee high conductivity. The crystal structure, phase composition and surface morphology were characterized by XRD, SEM and TEM measurement. The as-prepared Ni/a-MWCNT nanohybrid was immobilized onto glassy carbon electrode (GCE) surface for constructing phenol sensor. The phenol sensing performance indicated that Ni/a-MWCNT/GCE exhibited an amazing detection performance with rapid response time of 4 s, a relatively wide detection range from 0.01 mM to 0.48 mM, a detection limit of $7.07{\mu}M$ and high sensitivity of $566.2{\mu}A\;mM^{-1}\;cm^{-2}$. The superior selectivity, reproducibility, stability and applicability in real sample of Ni/a-MWCNT/GCE endowed it with potential application in discharged wastewater.

A Simple and Efficient Method to Determine Montelukast in Rat Plasma Using Liquid-Liquid Extraction and Tandem Mass Spectrometry

  • Kim, Dong Yoon;Lee, Hyo Chun;Jang, Yong Jin;Kim, Jin Hee;Lee, Ha Ryeong;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.71-76
    • /
    • 2020
  • While montelukast (ML), a cysteinyl-leukotriene type 1 receptor (CysLT1) antagonist is widely used to treat symptoms of rhinitis or asthma, its formulations are mainly limited to solid preparation due to its instability. Recently, there have been attempts to develop various ML dosage forms, and this situation increases the demand of sensitive and creditable methods to determine ML in various samples such as plasma. Thus, here, a simple and efficient method to determine ML in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was presented. The mixture of DCM:EtOAc (25:75, v/v), the optimized extract solvent for LLE was found to be effective to extract ML without hydrophilic salts and proteins from the sample with limited volume. Also, the use of zafirlukast, instead of expensive ML-d6, as the internal standard makes the present method economical. The developed method was successfully validated in terms of selectivity, matrix effects (-14.8--6.9%), linearity (r230.998 within 0.5-500 ng/mL), sensitivity (the limit of detection and the lower limit of quantitation, ≤0.5 ng/mL), accuracy (88.4-100.6%), precision (3.0-13.3%), and recovery (80.8-86.3%) by following the FDA guidelines. Finally, the applicability of the validated method to pharmacokinetics (PK) studies was confirmed by the successful determination of PK parameters through it following oral administration of Singulair® granule in rats. Therefore, the present method can contribute to the development of new ML formulations through its performance to determine ML in rat plasma efficiently and sensitively.

Rapid Detection of Clostridium tetani by Recombinase Polymerase Amplification Using an Exo Probe

  • Guo, Mingjing;Feng, Pan;Zhang, Liqun;Feng, Chunfeng;Fu, Jie;Pu, Xiaoyun;Liu, Fei
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.91-98
    • /
    • 2022
  • Tetanus is a potentially fatal public health illness resulted from the neurotoxins generated by Clostridium tetani. C. tetani is not easily culturable and culturing the relevant bacteria from infected wounds has rarely been useful in diagnosis; PCR-based assays can only be conducted at highly sophisticated laboratories. Therefore, a real-time recombinase polymerase amplification assay (Exo-RPA) was constructed to identify the fragments of the neurotoxin gene of C. tetani. Primers and the exo probe targeting the conserved region were designed, and the resulting amplicons could be detected in less than 20 min, with a detection limit of 20 copies/reaction. The RPA assay displayed good selectivity, and there were no cross-reactions with other infectious bacteria common in penetrating wounds. Tests of target-spiked serum and pus extract revealed that RPA is robust to interfering factors and has great potential for further development for biological sample analysis. This method has been confirmed to be reliable for discriminating between toxic and nontoxic C. tetani strains. The RPA assay dramatically improves the diagnostic efficacy with simplified device architecture and is a promising alternative to real-time PCR for tetanus detection.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

A New Removal Method of Glutelin Storage Proteins for the Proteome Study of Non-Glutelin Proteins in Rice Seeds (벼종자 미랑 단백질의 프로테오믹스 연구를 위한 글루테린 저장 단백질의 제거방법)

  • Woo, Sun-Hee;Kim, Se-Young;Kim, Tae-Seon;Cho, Seong-Woo;Cho, Kun;Chung, Keun-Yook;Kim, Sun-Lim;Cho, Yong-Gu;Kim, Hong-Sig;Song, Boem-Heon;Lee, Chul-Won;Jong, Seung-Keun;Park, Young-Mok
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.51 no.spc1
    • /
    • pp.92-102
    • /
    • 2006
  • Abundant proteins often cause problems in proteome study. Glutelin family proteins (hereafter referred to glutelin) are present in rice proteome sample as over-whelming constituents with very high abundance. In order to increase the number of identified proteins in rice proteome study, we developed a newly improved method for sample preparation through the removal of glutelin. When the protein samples from rice seed were extracted by the conventional trichloroacetic acid (TCA) extraction method, glutelin accounts for about 60% of total rice seed proteins in SDS gels. Using our new water extraction method, glutelin consists of only about 10% of total proteins. After analyzing on a two-dimensional gel electrophoresis (2-DE), 937 protein spots were detected using the conventional TCA extraction method. On the other hand, 1240 proteins could be seen using the new water extraction method. The selectivity for non-glutelin and less abundant protein by the water extraction method was also confirmed by ESI-Q/TOF mass spectrometry analysis. Thus, the new water extraction method developed here can be efficiently used to study the proteome analysis of rice storage seed.